PDFWAC 296-52-69070

Explosives recovered from misfires.

(1) Storage. Explosives recovered from misfires must be placed in a separate licensed magazine until they can be disposed of according to the manufacturer's recommendations.
(2) Detonator use. Detonators suspected of being defective cannot be reused.
(3) Disposal. The blaster in charge must dispose of explosives and detonators according to the manufacturer's recommendations.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 17-16-132, § 296-52-69070, filed 8/1/17, effective 9/1/17. Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-69070, filed 1/23/02, effective 3/1/02.]