EMERGENCY RULES
Purpose: To extend the current emergency rule affecting amendments to the 2003 International Fire Code, as amended by WSR 04-13-095. Amend Section 804, Decorative Vegetation, to limit restrictions on placement of cut trees. Amend Chapter 4 requirements for fire evacuation plan review, to allow jurisdictions to determine when a full review is necessary. Amend Chapter 3 to allow BBQ grills on R-2 decks and balconies.
Citation of Existing Rules Affected by this Order: Amending WAC 51-54-0300, 51-54-0400, and 51-54-0800.
Statutory Authority for Adoption: RCW 19.27.031 and 19.27.074.
Under RCW 34.05.350 the agency for good cause finds that immediate adoption, amendment, or repeal of a rule is necessary for the preservation of the public health, safety, or general welfare, and that observing the time requirements of notice and opportunity to comment upon adoption of a permanent rule would be contrary to the public interest.
Reasons for this Finding: The State Building Code Council (council), based on the following good cause, finds that an emergency affecting the general welfare of the state of Washington exists. The council further finds that immediate amendment of a certain council rule is necessary for the public welfare and that observing the time requirements of notice and opportunity to comment would be contrary to the public interest.
The declaration of emergency affecting the general welfare of the state of Washington is based on the following findings:
The 2003 International Fire Code, adopted by the council in November 2003 and effective July 1, 2004, contains provisions that restrict the placement of seasonal cut trees in certain building types. These restrictions were not found in the previous code. The intent behind the model code provision is that these trees are shipped into an area after cutting and are therefore already dried out once they reach the marketplace. Since most trees originate in the Northwest, it is felt that some of these restrictions can be safely removed. Immediate amendment allows continued use of local trees, benefitting the public, the industry, and the enforcement community.
Another provision found in the 2003 International Fire Code concerns jurisdictional review of fire safety and evacuation plans. The technical advisory group and the council feel that the requirements found in Chapter 4 of this code are onerous and create undue expense for both building managers and review personnel. The amendments to this chapter would allow the local fire code official to determine when a full review of plans is necessary.
The final provision, found in Section 308.3, restricts the use of charcoal and propane grills in all occupancies except one- and two-family dwellings. The council feels this restriction is onerous and unenforceable.
It is felt that these amendments should be effective on the same date as the model code and state amendments go into effect on July 1, 2004.
The council is in the process of adopting permanent rules on these matters. However, the permanent rules will not be effective until the end of the 2005 legislative session as per RCW 19.27.074.
Number of Sections Adopted in Order to Comply with Federal Statute: New 0, Amended 0, Repealed 0; Federal Rules or Standards: New 0, Amended 0, Repealed 0; or Recently Enacted State Statutes: New 0, Amended 0, Repealed 0.
Number of Sections Adopted at Request of a Nongovernmental Entity: New 0, Amended 2, Repealed 0.
Number of Sections Adopted on the Agency's Own Initiative: New 0, Amended 1, Repealed 0.
Number of Sections Adopted in Order to Clarify, Streamline, or Reform Agency Procedures: New 0, Amended 0, Repealed 0.
Number of Sections Adopted Using Negotiated Rule Making: New 0, Amended 0, Repealed 0; Pilot Rule Making: New 0, Amended 0, Repealed 0; or Other Alternative Rule Making: New 0, Amended 0, Repealed 0.
Date Adopted: October 15, 2004.
October 29, 2004
Tim Nogler
for Stan Price
Council Chair
OTS-7223.2
AMENDATORY SECTION(Amending WSR 04-01-105, filed 12/17/03,
effective 7/1/04)
WAC 51-54-0300
Chapter 3 -- General precautions against
fire.
307.2.1 Authorization. Where required by state or local law
or regulations, open burning shall only be permitted with
prior approval from the state or local air and water quality
management authority, provided that all conditions specified
in the authorization are followed. See also chapter 173-425 WAC.
307.3.2 Recreational fires. Recreational fires shall not be
conducted within 25 feet of a structure or combustible
material. Conditions which could cause a fire to spread
within 25 feet of a structure shall be eliminated prior to
ignition. See also chapter 173-425 WAC.
308.3.1 Open-flame cooking devices. This section is not
adopted.
308.3.1.1 Liquefied-petroleum-gas-fueled cooking devices.
This section is not adopted.
308.3.4 Aisles and exits. Candles shall be prohibited in
areas where occupants stand, or in an aisle or exit.
EXCEPTION: | Candles used in religious ceremonies. See RCW 19.27.031(3). |
308.3.7 Group A Occupancies. Open-flame devices shall not be
used in a Group A Occupancy.
EXCEPTIONS: | 1. Open-flame devices are allowed to be used in the following situations: |
1.1 Where necessary for ceremonial or religious purposes in accordance with Section 308.5. | |
1.2 On stages and platforms as a necessary part of a performance in accordance with Section 308.6, provided approved precautions are taken to prevent ignition of a combustible material or injury to occupants. | |
1.3 Where candles on tables are securely supported on substantial noncombustible bases and the candle flames are protected provided approved precautions are taken to prevent ignition of a combustible material or injury to occupants. | |
2. Heat-producing equipment complying with Chapter 6 and the International Mechanical Code. | |
3. Gas lights are allowed to be used provided adequate precautions satisfactory to the fire code official are taken to prevent ignition of combustible materials. |
[Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-105, § 51-54-0300, filed 12/17/03, effective 7/1/04.]
401.2 Approval. Where required by the fire code official,
fire safety plans, emergency procedures, and employee training
programs shall be approved.
404.2 Where required. A fire safety and evacuation plan shall
be prepared and maintained in accordance with this chapter for
the following occupancies and buildings when required by the
fire code official.
1. Group A having an occupant load of 100 or more.
2. Group E.
3. Group H.
4. Group I.
5. Group R-1.
6. Group R-4.
7. High-rise buildings.
8. Group M buildings having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge.
9. Covered malls exceeding 50,000 sf in aggregate floor area.
10. Underground buildings.
11. Buildings with an atrium and having an occupancy in Group A, E, or M.
404.4 Maintenance. Fire safety and evacuation plans shall be
reviewed by the owner or occupant annually or as necessitated
by changes in staff assignments, occupancy, or the physical
arrangement of the building.
408.11.1.1 Approval. The lease plan shall be submitted to the
fire code official, and shall be maintained on-site for
immediate reference by responding fire service personnel.
408.11.1.2 Revisions. The lease plan shall be reviewed by the
owner or occupant and revised annually or as often as
necessary to keep them current.
[]
804.l.1 Restricted occupancies. Natural cut trees shall be
prohibited in Group I-1, I-2, I-3, I-4, LC and R-4
occupancies.
804.l.2 Support devices. The support device that holds the
tree in an upright position shall be of a type that is stable
and that meets all of the following criteria:
1. The device shall hold the tree securely and be of adequate size to avoid tipping over of the tree.
2. The device shall be capable of containing a minimum supply of water in accordance with Table 804.1.2.
3. The water level, when full, shall cover the tree stem at least 2 inches (51 mm). The water level shall be maintained above the fresh cut and checked at least once daily.
804.l.3 Dryness. The tree shall be removed from the building
whenever the tree is determined to be dry by needle
pliability, discoloration or other approved means as approved
by the fire code official. The tree shall be checked daily
for dryness.
Tree Stem Diameter (inches) | Minimum Support Stand Water Capacity (gallons) | Typical Daily Water Transpiration Amount (gallons) |
Up to 4 | 1 | 1/4 to 1 |
4 to 6 | 1 1/2 | 1 1/4 to 1 1/2 |
7 to 8 | 2 | 1 3/4 to 2 |
9 to 12 | 3 | 2 1/4 to 3 |
13 and over | 4 | Over 3 |
[]