WSR 07-03-043

PERMANENT RULES

BUILDING CODE COUNCIL


[ Filed January 11, 2007, 10:59 a.m. , effective July 1, 2007 ]


     Effective Date of Rule: July 1, 2007.

     Purpose: To adopt and amend the 2006 Edition of the Uniform Plumbing Code Appendices, chapter 51-57 WAC.

     Citation of Existing Rules Affected by this Order: Amending 6.

     Statutory Authority for Adoption: RCW 19.27.190 and 19.27.020.

     Other Authority: Chapters 19.27 and 34.05 RCW.

      Adopted under notice filed as WSR 06-16-111 on August 1, 2006.

     Number of Sections Adopted in Order to Comply with Federal Statute: New 0, Amended 0, Repealed 0; Federal Rules or Standards: New 0, Amended 0, Repealed 0; or Recently Enacted State Statutes: New 0, Amended 0, Repealed 0.

     Number of Sections Adopted at Request of a Nongovernmental Entity: New 0, Amended 0, Repealed 0.

     Number of Sections Adopted on the Agency's Own Initiative: New 1, Amended 6, Repealed 0.

     Number of Sections Adopted in Order to Clarify, Streamline, or Reform Agency Procedures: New 0, Amended 0, Repealed 0.

     Number of Sections Adopted Using Negotiated Rule Making: New 0, Amended 0, Repealed 0;      Pilot Rule Making: New 0, Amended 0, Repealed 0; or Other Alternative Rule Making: New 1, Amended 6, Repealed 0.

     Date Adopted: November 17, 2006.

Tim Nogler

for John Neff

Council Chair

OTS-8966.1


AMENDATORY SECTION(Amending WSR 04-01-110, filed 12/17/03, effective 7/1/04)

WAC 51-57-003   Uniform Plumbing Code Standards.   The ((2003)) 2006 edition of the Uniform Plumbing Code Standards (Appendixes A, B and I), published by the International Association of Plumbing and Mechanical Officials are hereby adopted by reference.

[Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-110, § 51-57-003, filed 12/17/03, effective 7/1/04; 02-01-114, § 51-57-003, filed 12/18/01, effective 7/1/02.]


NEW SECTION
WAC 51-57-004   Conflicts between Appendix I and the manufacturer's installation instructions.   Where a conflict exists between the provisions of Appendix I and the manufacturer's installation instructions, the conditions of the listing and the manufacturer's installation instructions shall apply.

[]


AMENDATORY SECTION(Amending WSR 02-01-114, filed 12/18/01, effective 7/1/02)

WAC 51-57-007   Exceptions.   The exceptions and amendments to the ((Uniform)) Model Codes contained in the provisions of chapter 19.27 RCW shall apply in cases of conflict with any of the provisions of these rules.

[Statutory Authority: RCW 19.27.031, 19.27.074. 02-01-114, § 51-57-007, filed 12/18/01, effective 7/1/02.]


AMENDATORY SECTION(Amending WSR 04-01-110, filed 12/17/03, effective 7/1/04)

WAC 51-57-008   Implementation.   The Uniform Plumbing Code Standards adopted by chapter 19.27 RCW shall become effective in all counties and cities of this state on July 1, ((2004)) 2007, unless local government residential amendments have been approved by the state building code council.

[Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-110, § 51-57-008, filed 12/17/03, effective 7/1/04; 02-01-114, § 51-57-008, filed 12/18/01, effective 7/1/02.]


AMENDATORY SECTION(Amending WSR 04-01-110, filed 12/17/03, effective 7/1/04)

WAC 51-57-202000   Installation standard 20-200 -- CPVC solvent cemented hot and cold water distribution systems.  


((301.1.1 Materials. Materials shall comply with the following:


((Materials ASTM Std
Raw Material - CPVC 23447-B D1784-95
IPS pipe
Sch 40 (1/2 in., 3/4 in., and 1 in.) F 441-89e1
Sch 80 (1/2 in. - 2 in.) F 441-94
Tubing
SDR 11 (1/2 in. - 2 in.) D2846-93
Fittings
Sch 40 (1/2 in., 3/4 in., and 1 in.) F 438-93
Sch 80 (1/2 in. - 2 in.) F 439-93a
Tube Fittings (1/2 in. - 2 in.) D2846-93))

2.1.2 Primer. Listed primers shall be used that are compatible with the type of listed CPVC cement and pipe used. The primer shall be a true solvent for CPVC, containing no slow-drying ingredient. Cleaners shall not be allowed to be used as a substitute or equivalent for a listed primer.

EXCEPTION: Listed solvent cements that do not require the use of primer shall be permitted for use with CPVC pipe and fittings, manufactured in accordance with ASTM D2845 (((1/2 in. - 2 in.))), 1/2 inch through 2 inches in diameter.

[Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-110, § 51-57-202000, filed 12/17/03, effective 7/1/04.]


AMENDATORY SECTION(Amending WSR 02-01-114, filed 12/18/01, effective 7/1/02)

WAC 51-57-790000   Installation Standard ((7-90)) 7-03 -- Polyethylene cold water building supply and yard piping.  


((604.1)) 2.6.1 Location. Polyethylene piping may terminate within a building or structure. The connection to the potable water distribution system shall be accessible, except that it may be buried underground outside of the building or structure in an accessible location. Barbed insert fittings with hose clamps are prohibited within a building.

[Statutory Authority: RCW 19.27.031, 19.27.074. 02-01-114, § 51-57-790000, filed 12/18/01, effective 7/1/02.]


AMENDATORY SECTION(Amending WSR 02-01-114, filed 12/18/01, effective 7/1/02)

WAC 51-57-895000   Installation Standard ((8-95)) 8-03 -- PVC cold water building supply and yard piping.  


((604.1)) 2.7.1 Location. PVC piping may terminate within a building or structure. The connection to the potable water distribution system shall be accessible, except that it may be buried underground outside of the building or structure in an accessible location.

[Statutory Authority: RCW 19.27.031, 19.27.074. 02-01-114, § 51-57-895000, filed 12/18/01, effective 7/1/02.]

© Washington State Code Reviser's Office