PERMANENT RULES
LABOR AND INDUSTRIES
Effective Date of Rule: April 1, 2007.
Purpose: The Occupational Safety and Health Administration (OSHA) recently adopted rules regulating hexavalent chromium. We made changes to our permissible exposure limit table to remain as-effective-as OSHA. In addition, general ventilation requirements in chapter 296-62 WAC, the general occupational health standards were repealed from that chapter and moved into chapter 296-841 WAC, the general exposure control sections. We also changed the title of the rule, reformatted it, and clarified some language.
Amended sections:
Chapter 296-841 WAC, Respiratory hazards:
| Changes were being made throughout this rule to bring it into compliance with OSHA, to change the title to airborne hazards, and to further clarify language. |
| General ventilation requirements were moved from chapter 296-62 WAC into this chapter. |
Repealed sections:
Chapter 296-62 WAC, General occupational health standards.
| General ventilation requirements were repealed from this chapter and moved into chapter 296-841 WAC. |
Citation of Existing Rules Affected by this Order: Amending WAC 296-841-100 Scope, 296-841-200 Evaluate and control employee exposures, 296-841-20005 Exposure evaluations, 296-841-20010 Exposure controls, 296-841-20015 Respirators, 296-841-20020 Notification, 296-841-20025 Permissible exposure limits, 296-841-300 Definitions, 296-78-71015 Tanks and chemicals, 296-155-20301 Definitions, 296-304-01009 Precautions for hot work, 296-806-47502 Guard drum sanders, 296-809-800 Definitions, 296-824-800 Definitions, 296-828-100 Scope, 296-828-20005 Chemical hygiene plan, 296-839-30005 Develop or obtain material safety data sheets (MSDSs), 296-849-11030 Exposure evaluations, 296-849-13005 Exposure control plan and 296-849-13020 Exposure controls; and repealing WAC 296-62-100 Oxygen deficient atmospheres, 296-62-110 Ventilation, 296-62-11001 Definition, 296-62-11003 Ventilation guide, 296-62-11005 Adequate system, 296-62-11007 Exhaust, 296-62-11009 Make-up air quantity, 296-62-11011 Design and operation, 296-62-11013 Compatibility of systems, and 296-62-11017 Grinding, polishing, and buffing operations.
Statutory Authority for Adoption: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060.
Adopted under notice filed as WSR 07-01-079 on December 19, 2007 [2006].
Number of Sections Adopted in Order to Comply with Federal Statute: New 0, Amended 0, Repealed 0; Federal Rules or Standards: New 0, Amended 1, Repealed 0; or Recently Enacted State Statutes: New 0, Amended 0, Repealed 0.
Number of Sections Adopted at Request of a Nongovernmental Entity: New 0, Amended 0, Repealed 0.
Number of Sections Adopted on the Agency's Own Initiative: New 0, Amended 0, Repealed 0.
Number of Sections Adopted in Order to Clarify, Streamline, or Reform Agency Procedures: New 0, Amended 20, Repealed 10.
Number of Sections Adopted Using Negotiated Rule Making: New 0, Amended 21, Repealed 0; Pilot Rule Making: New 0, Amended 0, Repealed 0; or Other Alternative Rule Making: New 0, Amended 0, Repealed 0.
Date Adopted: February 20, 2007.
Judy Schurke
Acting Director
OTS-8864.3
((RESPIRATORY HAZARDS)) AIRBORNE CONTAMINANTS
Are exposed to a respiratory hazard
OR
Could be exposed to one of the specific hazards listed below.
This chapter applies to any workplace with potential or actual employee exposure to respiratory hazards. It requires you to protect employees from respiratory hazards by applying this protection strategy:
Evaluate employee exposures to determine if controls are needed
Use feasible controls. For example, enclose or confine the operation, use ventilation systems, or substitute with less toxic material
Use respirators if controls are not feasible or if they cannot completely remove the hazard.
Definition:
Exposed or exposure:
The contact an employee has with a toxic substance, harmful physical agent or oxygen deficient condition, whether or not protection is provided by respirators or other personal protective equipment (PPE). Exposure can occur through various routes of entry, such as inhalation, ingestion, skin contact, or skin absorption.
(( |
||
chloropropane |
||
The following are examples of airborne contaminants that may become airborne hazards in some workplaces:
Chemicals listed in Table 3, Permissible Exposure Limits (PELs) for Airborne Contaminants
Any substance:
▪ Listed in the latest edition of the NIOSH Registry of Toxic Effects of Chemical Substances
▪ For which positive evidence of an acute or chronic health hazard exists through tests conducted by, or known to, the employer
▪ That may pose a hazard to human health as stated on a material safety data sheet (MSDS) kept by, or known to, the employer
Biological agents such as harmful bacteria, viruses or fungi
▪ Examples include TB aerosols and anthrax
Pesticides
Chemicals used as crowd control agents, such as pepper spray
Chemicals present at clandestine drug labs.
Airborne contaminants exist in a variety of physical forms such as dusts, fibers, fogs, fumes, mists, gases, smoke, sprays, vapors, or aerosols.
Definition:
Exposed or exposure:
The contact an employee has with a toxic substance, harmful physical agent or oxygen-deficient condition, whether or not protection is provided by respirators or other personal protective equipment (PPE). Exposure can occur through various routes of entry, such as inhalation, ingestion, skin contact, or skin absorption.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 06-08-087, § 296-841-100, filed 4/4/06, effective 9/1/06; 05-17-168, § 296-841-100, filed 8/23/05, effective 1/1/06; 04-18-079, § 296-841-100, filed 8/31/04, effective 11/1/04; 03-20-115, § 296-841-100, filed 10/1/03, effective 1/1/04.]
((Summary
Your responsibility:
To protect your employees from exposure to respiratory hazards in the workplace by identifying and controlling the hazards.
You must:
Identify and evaluate employee exposures
Control employee exposures
Use respirators
Notify employees
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 03-20-115, § 296-841-200, filed 10/1/03, effective 1/1/04.]
Note: | Resources include product labels, material safety data sheets (MSDSs), manufacturer recommendations, and industry protocols. |
[]
((You must:
Make sure employees are protected from potentially hazardous exposure while you perform your evaluation
Perform your evaluation without considering the protection provided to employees by a respirator
Determine the form of the hazard, such as dust, mist, gas, oxygen deficiency, or biological agent.
Make sure you consider:
Potential emergency and rescue situations that may occur, such as equipment or power failures, uncontrolled chemical reactions, fire, explosion, or human error
Workplace conditions such as work processes, types of material, control methods, work practices and environmental conditions.
Determine or reasonably estimate whether any employee is or could be exposed to any of the following:
Any airborne substance above a permissible exposure limit (PEL) listed in Table 3
A substance at or above the action level (AL) specified in the rule for that substance
Any other respiratory hazard.
Use any of the following to determine employee exposure:
Information that would allow an estimate of the level of employee exposure, such as MSDSs or pesticide labels, observations, measurements or calculations
Data demonstrating that a particular product, material or activity cannot result in employee exposure at or above the AL or PEL
Personal air samples that represent an employee's usual
or worst case exposure for the entire shift.
Consider the atmosphere to be immediately dangerous to life or health (IDLH) when you cannot determine or reasonably estimate employee exposure
Make sure employee exposure, to two or more substances with additive health effects, is evaluated using this formula:
(( |
L1 |
L2 |
Ln)) |
(( |
|
An airborne contaminant above a permissible exposure limit (PEL) listed in Table 3;
OR
Other airborne hazards, such as biological hazards.
Note: | When evaluating air contaminants, keep in mind that oxygen deficient conditions may also occur due to: |
Processes such as fermentation, decomposition of organic matter, or combustion of fossil fuels | |
Displacement by another gas such as nitrogen or carbon dioxide | |
Rules for specific substances may contain additional requirements for determining employee exposure | |
Samples from a representative group of employees may be used for other employees performing the same work activities, when the duration and level of exposure are similar. |
(3) Do all the following when you perform your evaluation:
(a) Determine the form of the airborne contaminant, such as dust, mist, gas, or biological agent.
(b) Make sure you don't use the amount of protection provided to employees by respirators as a factor in determining whether employees are exposed to an airborne hazard.
(c) Make sure any air monitoring results used to determine employee exposures are based on personal air samples taken from, or representative of, the employee's breathing zone.
▪ You may use area sampling to screen for the presence of an airborne contaminant; however, results from area sampling can't be used if they don't adequately represent exposure of affected employees.
(d) Include potential emergency and rescue situations that may occur, such as equipment or power failures, uncontrolled chemical reactions, fire, explosion, or human error.
(e) Include workplace conditions such as work processes, types of material, exposure control methods, work practices, and environmental conditions.
(f) Address extended work periods. For work shifts longer than eight hours, evaluate the continuous eight-hour portion of the shift expected to have the highest average exposure concentration.
(4) Use either of the following types of documentation to conclusively demonstrate that employee exposure cannot meet or exceed any PEL for the airborne contaminant during any reasonably anticipated conditions:
Personal air samples that represent an employee's usual or worst-case exposure during the entire shift.
OR
Specific information about products, materials, or
activities that provides for an estimate of the level of
employee exposure such as material safety data sheets (MSDSs),
observations, previous air sampling results, other
measurements, calculations, or pesticide labels.
Note: | You should use methods of sampling and analysis that have been validated by the laboratory performing the analysis. |
Em | = | C1 L1 |
+ | C2 L2 |
+ | ... | + | Cn Ln |
The symbol |
Is the . . . |
E | Equivalent exposure for the mixture. When the value of E is greater than 1, an airborne hazard is present. |
C | Concentration of a specific airborne contaminant. |
L | TWA8, STEL, or ceiling limit for that airborne contaminant, from Table 3, Permissible Exposure Limits (PELs) for Airborne Contaminants. |
Note: | When results from your exposure evaluation indicate an airborne hazard, follow requirements in WAC 296-841-20010 through 296-841-20020 of this chapter. |
When changes occur that increase the level of exposure to an airborne hazard, you may need to conduct a new exposure evaluation to make sure exposure controls and other protective measures are sufficient. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 04-18-079, § 296-841-20005, filed 8/31/04, effective 11/1/04; 03-20-115, § 296-841-20005, filed 10/1/03, effective 1/1/04.]
((You must:
Use feasible controls to protect employees from exposure to respiratory hazards by:
Reducing employee exposure to a level that removes the respiratory hazard, such as to a level below the permissible exposure limits (PEL) in Table 3;
OR
Reducing the exposure to the lowest achievable level, when the respiratory hazard cannot be removed.
IMPORTANT:
Using respirators and other PPE is not a substitute for the feasible controls required by this section.
Note: The following table gives you examples of control methods.)) IMPORTANT:
Respirators and other personal protective equipment are not exposure controls. Respirators may be used to protect employees while exposure controls are being installed or when it's not feasible to use exposure controls to remove or reduce the airborne hazard.
(1) Use feasible exposure controls to reduce employee exposure to one of the following:
A level below the permissible exposure limits (PEL) in Table 3
A level that removes the airborne hazard, when no PEL is established
The lowest achievable level, when exposure cannot be reduced to below the PEL or the airborne hazard can't be removed.
(2) Make sure exposure controls don't create or increase employee health hazards. For example, when ventilation systems are installed:
Prevent contaminated exhaust air from either:
▪ Reentering the building in harmful amounts
or
▪ Exposing any employee to a health hazard.
Temper make-up air, when necessary
Prevent employee exposure to excessive air velocities.
(3) Use make-up air systems that will not interfere with the effectiveness of the exhaust air system.
For example, make sure enough make-up air is provided
to replace the amount of air exhausted.
Note: | Table 1 provides examples of possible exposure controls. |
Table 1
Examples of Possible Controls
(( |
For example: |
Using a different chemical (this is also known as substitution) | Choose a chemical with a lower evaporation rate or vapor pressure |
Choose a chemical
(( |
|
Changing a process to
(( |
Use hand rolling or paint dipping instead of paint spraying |
Bolt items instead of welding them | |
Separating employees from emissions areas and sources | Use control rooms |
Build an enclosure around process machinery or other emissions sources | |
Automate a process | |
(( |
Install exhaust hoods or slots to capture emissions |
Use an exhausted enclosure (like a blasting cabinet or laboratory hood) | |
Other exposure controls include: | For example: |
Using general exhaust ventilation to dilute and remove emissions in the work area | Allow natural air movement to create an adequate airflow through an area |
Note: | Use mechanical fans |
This isn't recommended for control of highly toxic airborne contaminants such as carcinogens, where low exposures can still present a health hazard | |
(( |
|
(( |
Change the position of
the (( |
Limiting the amount of time employees can spend in a contaminated area. | Establish a contaminant-free area for tasks such as prep work that don't need to be done in the exposure area |
(( Some specific rules prohibit the use of this control method |
|
Implementing an employee rotation schedule | Have employees alternate working in the exposure area so that each employee gets less overall exposure |
Note: | |
This control will increase the number of employees exposed to the airborne contaminant. Due to this risk, employee rotation is NOT recommended for highly toxic airborne contaminants such as carcinogens, where low exposures can still present a health hazard. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 04-18-079, § 296-841-20010, filed 8/31/04, effective 11/1/04; 03-20-115, § 296-841-20010, filed 10/1/03, effective 1/1/04.]
((You must:
)) Require employees to use ((respiratory protection))
respirators when ((respiratory)) airborne hazards have not
been removed using feasible exposure controls. For example,
use respirators at any of the following times:
While exposure controls are being evaluated or put in place
When the ((respiratory)) airborne hazard is not
completely removed
When exposure controls are NOT feasible.
((Reference:
See chapter 296-842 WAC, Respirators, for respirator program requirements.))
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 03-20-115, § 296-841-20015, filed 10/1/03, effective 1/1/04.]
((You must:
)) Notify employees who are or may be exposed to
((respiratory)) airborne hazards, as specified in Table 2.
Note: | The notification may be provided either individually, to a group, or by posting of results in an appropriate location that is accessible to affected employees. |
Table 2
Notification Requirements
Notify employees of: | As follows: |
Any exposure result above a permissible exposure limit (PEL) | Within five business days, after the employee's exposure result is known to the employer |
The corrective action being taken to reduce employee exposure to or below the PEL | Within fifteen business days, after the employee's exposure result is known to the employer |
AND | |
The schedule for completion of the corrective action and any reasons why exposures cannot be lowered to below the PEL | |
((
|
|
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 04-18-079, § 296-841-20020, filed 8/31/04, effective 11/1/04; 03-20-115, § 296-841-20020, filed 10/1/03, effective 1/1/04.]
IMPORTANT:
The following information applies to Table 3, Permissible
Exposure Limits (PELs) for ((Air)) Airborne Contaminants.
(( Exposure needs to be determined from personal air
samples taken in the breathing zone OR from monitoring
representative of the employee's breathing zone.))
Ppm refers to parts of vapor or gas per million parts of air by volume, at 25 degrees C and 760 mm Hg pressure.
Mg/m3 refers to milligrams of ((substance)) an airborne
contaminant per cubic meter of air.
F/cc refers to fibers per cubic centimeter of air.
For a metal that is measured as the metal itself, only the CAS number for the metal is given. The CAS numbers for individual compounds of the metal are not provided. For more information about CAS registry numbers see the web site: http://www.cas.org.
(( Time weighted averages (TWA8) represent the maximum
allowed average exposure for any 8-hour time period. For work
periods longer than 8-hours the TWA8 needs to be determined
using the 8 continuous hours with the highest average
concentration.))
Short-term exposure limits (STEL) ((represent maximum
allowed average exposure for any)) pertain to fifteen-minute
exposure periods, unless another time period is noted in Table
3.
(( The ceiling represents the maximum allowed exposure
for the shortest time period that can feasibly be measured.))
An "X" in the "skin" column indicates the ((substance))
contaminant can be absorbed through the skin, either by
airborne or direct contact.
Personal protective equipment (PPE) to prevent skin contact may be needed to minimize the risk for adverse health effects when employees are exposed to these chemicals.
(()) Requirements for the use of gloves, coveralls,
goggles, and other personal protective equipment can be found
in WAC 296-800-160, Personal protective equipment (PPE).
Nuisance dusts (also known as inert dusts) are included in the Table 3 listing, particulates not otherwise regulated (PNOR).
The PNOR listing in Table 3 also applies to other particulate airborne contaminants for which a specific PEL is NOT listed unless the airborne contaminant is found to require a lower limit.
The respirable fraction of a particulate airborne contaminant is measured by sampling with a size-selector having the following characteristics:
Mean aerodynamic diameter in micrometers | Percent passing the selector |
1 | 97 |
2 | 91 |
3 | 74 |
4 | 50 |
5 | 30 |
6 | 17 |
7 | 9 |
8 | 5 |
10 | 1 |
(( |
CAS | TWA8 | STEL | Ceiling | Skin |
Abate (Temephos) | 3383-96-8 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Acetaldehyde | 75-07-0 | 100 ppm | 150 ppm | ---- | ---- |
Acetic acid | 64-19-7 | 10 ppm | 20 ppm | ---- | ---- |
Acetic anhydride | 108-24-7 | ---- | ---- | 5 ppm | ---- |
Actinolite (asbestiform) (as
asbestos) (see WAC 296-62-077 and |
---- | 0.1 f/cc | 1.0 f/cc (30 minutes) | ---- | ---- |
Acetone | 67-64-1 | 750 ppm | 1,000 ppm | ---- | ---- |
Acetonitrile | 75-05-8 | 40 ppm | 60 ppm | ---- | ---- |
2-Acetylaminofluorene (see WAC 296-62-073) |
53-96-3 | ---- | ---- | ---- | ---- |
Acetylene | 74-86-2 | Simple asphyxiant | ---- | ---- | ---- |
Acetylene dichloride (1,2-Dichloroethylene) |
540-59-0 | 200 ppm | 250 ppm | ---- | ---- |
Acetylene tetrabromide | 79-27-6 | 1 ppm | 3 ppm | ---- | ---- |
Acetylsalicylic acid (Aspirin) |
50-78-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Acrolein | 107-02-8 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Acrylamide | 79-06-1 | 0.03 mg/m3 | 0.09 mg/m3 | ---- | X |
Acrylic acid | 79-10-7 | 10 ppm | 20 ppm | ---- | X |
Acrylonitrile (Vinyl cyanide) (see WAC 296-62-07336) |
107-13-1 | 2 ppm | 10 ppm | ---- | ---- |
Aldrin | 309-00-2 | 0.25 mg/m3 | 0.75 mg/m3 | ---- | X |
Allyl alcohol | 107-18-6 | 2 ppm | 4 ppm | ---- | X |
Allyl chloride | 107-05-1 | 1 ppm | 2 ppm | ---- | ---- |
Allyl glycidyl ether (AGE) | 106-92-3 | 5 ppm | 10 ppm | ---- | ---- |
Allyl propyl disulfide | 2179-59-1 | 2 ppm | 3 ppm | ---- | ---- |
alpha-Alumina (Aluminum oxide) |
1344-28-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Aluminum (as Al) | 7429-90-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pyro powders | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Welding fumes | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Soluble salts | ---- | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Alkyls (NOC) | ---- | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Aluminum oxide (Alundum, Corundum) |
7429-90-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
4-Aminodiphenyl (see WAC 296-62-073) |
92-67-1 | ---- | ---- | ---- | ---- |
2-Aminoethanol (Ethanolamine) |
141-43-5 | 3 ppm | 6 ppm | ---- | ---- |
2-Aminopyridine | 504-29-0 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Amitrole | 61-82-5 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Ammonia | 7664-41-7 | 25 ppm | 35 ppm | ---- | ---- |
Ammonium chloride, fume | 12125-02-9 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Ammonium sulfamate (Ammate) | 7773-06-0 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5.0 mg/m3 | 10 mg/m3 | ---- | ---- |
Amosite (as asbestos) (see WAC 296-62-077 and and chapter 296-65 WAC) |
---- | 0.1 f/cc | 1.0 f/cc (30 minutes) | ---- | ---- |
n-Amyl acetate | 628-63-7 | 100 ppm | 150 ppm | ---- | ---- |
sec-Amyl acetate | 626-38-0 | 125 ppm | 156 ppm | ---- | ---- |
Aniline and homologues | 62-53-3 | 2 ppm | 4 ppm | ---- | X |
Anisidine (o, p-isomers) | 29191-52-4 | 0.1 ppm | 0.3 ppm | ---- | X |
Anthophyllite (asbestiform) (as asbestos) (see WAC 296-62-077 and |
---- | 0.1 f/cc | 1.0 f/cc (30 minutes) | ---- | ---- |
Antimony and compounds (as Sb) | 7440-36-0 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
ANTU (alpha Naphthyl thiourea) |
86-88-4 | 0.3 mg/m3 | 0.9 mg/m3 | ---- | ---- |
Argon | 7440-37-1 | Simple asphyxiant | ---- | ---- | ---- |
Arsenic, organic compounds (as As) |
7440-38-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Arsenic, inorganic compounds (as As) (when use is covered by (( 296-62-07347)) chapter 296-848 WAC) |
7440-38-2 | 0.01 mg/m3 | ---- | ---- | ---- |
Arsenic, inorganic compounds (as As) (when use is not covered by (( 296-62-07347)) chapter 296-848 WAC) |
7440-38-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Arsine | 7784-42-1 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Asbestos (see WAC 296-62-077 and chapter 296-65 WAC) |
---- | (( |
(( |
---- | ---- |
Asphalt (Petroleum fumes) | 8052-42-4 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Atrazine | 1912-24-9 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Azinphos methyl (Guthion) | 86-50-0 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Azodrin (Monocrotophos) | 6923-22-4 | 0.25 mg/m3 | 0.75 mg/m3 | ---- | ---- |
Barium, soluble compounds (as Ba) |
7440-39-3 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Barium sulfate | 7727-43-7 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Baygon (Propoxur) | 114-26-1 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Benomyl | 17804-35-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Benzene (see (( 296-62-07523)) chapter 296-849 WAC) |
71-43-2 | 1 ppm | 5 ppm | ---- | ---- |
Benzidine (see WAC 296-62-073) |
92-87-5 | ---- | ---- | ---- | ---- |
p-Benzoquinone (Quinone) |
106-51-4 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Benzo(a) pyrene (Coal tar pitch volatiles) |
65996-93-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Benzoyl peroxide | 94-36-0 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Benzyl chloride | 100-44-7 | 1ppm | 3 ppm | ---- | ---- |
Beryllium and beryllium compounds (as Be) |
7440-41-7 | 0.002 mg/m3 | 0.005 mg/m3 (30 min.) |
0.025 mg/m3 | ---- |
Biphenyl (Diphenyl) | 92-52-4 | 0.2 ppm | 0.6 ppm | ---- | ---- |
Bismuth telluride, undoped | 1304-82-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Bismuth telluride, Se-doped | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Borates, tetra, sodium salts | ---- | ---- | ---- | ---- | ---- |
Anhydrous | 1330-43-4 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Decahydrate | 1303-96-4 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pentahydrate | 12179-04-3 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Boron oxide | 1303-86-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Boron tribromide | 10294-33-4 | ---- | ---- | 1 ppm | ---- |
Boron trifluoride | 6737-07-2 | ---- | ---- | 1 ppm | ---- |
Bromacil | 314-40-9 | 1 ppm | 3 ppm | ---- | ---- |
Bromine | 7726-95-6 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Bromine pentafluoride | 7789-30-2 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Bromochloromethane (Chlorobromomthane) |
74-97-5 | 200 ppm | 250 ppm | ---- | ---- |
Bromoform | 15-25-2 | 0.5 ppm | 1.5 ppm | ---- | X |
Butadiene (1,3-butadiene) (see WAC 296-62-07460) |
106-99-0 | 1 ppm | 5 ppm | ---- | ---- |
Butane | 106-97-8 | 800 ppm | 1,000 ppm | ---- | ---- |
Butanethiol (Butyl mercaptan) |
109-79-5 | 0.5 ppm | 1.5 ppm | ---- | ---- |
2-Butanone (Methyl ethyl ketone) |
78-93-3 | 200 ppm | 300 ppm | ---- | ---- |
2-Butoxy ethanol (Butyl cellosolve) |
111-76-2 | 25 ppm | 38 ppm | ---- | X |
n-Butyl acetate | 123-86-4 | 150 ppm | 200 ppm | ---- | ---- |
sec-Butyl acetate | 105-46-4 | 200 ppm | 250 ppm | ---- | ---- |
tert-Butyl acetate | 540-88-5 | 200 ppm | 250 ppm | ---- | ---- |
Butyl acrylate | 141-32-2 | 10 ppm | 20 ppm | ---- | ---- |
n-Butyl alcohol | 71-36-3 | ---- | ---- | 50 ppm | X |
sec-Butyl alcohol | 78-92-2 | 100 ppm | 150 ppm | -- -- | ---- |
tert-Butyl alcohol | 75-65-0 | 100 ppm | 150 ppm | ---- | ---- |
Butylamine | 109-73-9 | ---- | ---- | 5 ppm | X |
Butyl cellosolve (2-Butoxy ethanol) | 111-76-2 | 25 ppm | 38 ppm | ---- | ---- |
tert-Butyl chromate (as (( (see WAC 296-62-08003) |
1189-85-1 | (( |
---- | 0.1 mg/m3 | X |
n-Butyl glycidyl ether (BGE) | 2426-08-6 | 25 ppm | 38 ppm | ---- | ---- |
n-Butyl lactate | 138-22-7 | 5 ppm | 10 ppm | --- | ---- |
Butyl mercaptan | 109-79-5 | 0.5 ppm | 1.5 ppm | ---- | ---- |
o-sec-Butylphenol | 89-72-5 | 5 ppm | 10 ppm | ---- | X |
p-tert-Butyl-toluene | 98-51-1 | 10 ppm | 20 ppm | ---- | ---- |
Cadmium oxide fume (as Cd) (see WAC 296-62-074 and 296-155-174) |
1306-19-0 | 0.005 mg/m3 | ---- | -- -- | ---- |
Cadmium dust and salts (as Cd) (see WAC 296-62-074 and 296-155-174) |
7440-43-9 | 0.005 mg/m3 | ---- | ---- | ---- |
Calcium arsenate (see (( |
---- | 0.01 mg/m3 | ---- | ---- | ---- |
Calcium carbonate | 1317-65-3 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Calcium cyanamide | 156-62-7 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Calcium hydroxide | 1305-62-0 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Calcium oxide | 1305-78-8 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Calcium silicate | 1344-95-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Calcium sulfate | 7778-18-9 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Camphor (synthetic) | 76-22-2 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Caprolactam | 105-60-2 | ---- | ---- | ---- | ---- |
Dust | ---- | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Vapor | ---- | 5 ppm | 10 ppm | ---- | ---- |
Captafol (Difolatan) |
2425-06-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Captan | 133-06-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Carbaryl (Sevin) | 63-25-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Carbofuran (Furadon) | 1563-66-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Carbon black | 1333-86-4 | 3.5 mg/m3 | 7 mg/m3 | ---- | ---- |
Carbon dioxide | 124-38-9 | 5,000 ppm | 30,000 ppm | ---- | ---- |
Carbon disulfide | 75-15-0 | 4 ppm | 12 ppm | ---- | X |
Carbon monoxide | 630-08-0 | 35 ppm | 200 ppm (5 min.) | 1,500 ppm | ---- |
Carbon tetrabromide | 558-13-4 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Carbon tetrachloride (Tetrachloromethane) |
56-23-5 | 2 ppm | 4 ppm | ---- | X |
Carbonyl chloride (Phosgene) |
7803-51-2 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Carbonyl fluoride | 353-50-4 | 2 ppm | 5 ppm | ---- | ---- |
Catechol (Pyrocatechol) | 120-80-9 | 5 ppm | 10 ppm | ---- | X |
Cellosolve acetate (2-Ethoxyethylacetate) |
111-15-9 | 5 ppm | 10 ppm | ---- | X |
Cellulose (paper fiber) | 9004-34-6 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Cesium hydroxide | 21351-79-1 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Chlordane | 57-74-9 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Chlorinated camphene (Toxaphen) |
8001-35-2 | 0.5 mg/m3 | 1 mg/m3 | ---- | X |
Chlorinated diphenyl oxide | 55720-99-5 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Chlorine | 7782-50-5 | 0.5 ppm | ---- | 1 ppm | ---- |
Chlorine dioxide | 10049-04-4 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Chlorine trifluoride | 7790-91-2 | ---- | ---- | 0.1 ppm | ---- |
Chloroacetaldehyde | 107-20-0 | ---- | ---- | 1 ppm | ---- |
a-Chloroacetophenone (Phenacyl chloride) |
532-21-4 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Chloroacetyl chloride | 79-04-9 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Chlorobenzene (Monochlorobenzene) |
108-90-7 | 75 ppm | 113 ppm | ---- | ---- |
o-Chlorobenzylidene malononitrile (OCBM) |
2698-41-1 | ---- | ---- | 0.05 ppm | X |
Chlorobromomethane | 74-97-5 | 200 ppm | 250 ppm | ---- | ---- |
2-Chloro-1, 3-butadiene (beta-Chloroprene) |
126-99-8 | 10 ppm | 20 ppm | ---- | X |
Chlorodifluoromethane | 75-45-6 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Chlorodiphenyl (42% Chlorine) (PCB) (Polychlorobiphenyls) |
53469-21-9 | 1 mg/m3 | 3 mg/m3 | ---- | X |
Chlorodiphenyl (54% Chlorine) (Polychlorobiphenyls (PCB)) |
11097-69-1 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
1-Chloro-2, 3-epoxypropane (Epichlorhydrin) |
106-89-8 | 2 ppm | 4 ppm | ---- | X |
2-Chloroethanol (Ethylene chlorohydrin) |
107-07-3 | ---- | ---- | 1 ppm | X |
Chloroethylene (vinyl chloride) (See WAC 296-62-07329) |
75-01-4 | 1 ppm | 5 ppm | ---- | ---- |
Chloroform (Trichloromethane) | 67-66-3 | 2 ppm | 4 ppm | ---- | ---- |
1-Chloro-1-nitropropane | 600-25-9 | 2 ppm | 4 ppm | ---- | ---- |
bis-Chloromethyl ether (see WAC 296-62-073) |
542-88-1 | ---- | ---- | ---- | ---- |
Chloromethyl methyl ether (Methyl chloromethyl ether) (see WAC 296-62-073) |
107-30-2 | ---- | ---- | ---- | ---- |
Chloropentafluoroethane | 76-15-3 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Chloropicrin (Nitrotrichloromethane) | 76-06-2 | 0.1 ppm | 0.3 ppm | ---- | ---- |
beta-Chloroprene (2-Chloro-1, 3-butadiene) |
126-99-8 | 10 ppm | 20 ppm | ---- | X |
o-Chlorostyrene | 2039-87-4 | 50 ppm | 75 ppm | ---- | ---- |
o-Chlorotoluene | 95-49-8 | 50 ppm | 75 ppm | ---- | ---- |
2-Chloro-6-trichloromethyl pyridine (Nitrapyrin) |
1929-82-4 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Chlorpyrifos | 2921-88-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Chromic acid and chromates (as (( (when the compound is not covered by WAC 296-62-08003) |
Varies with compound |
(( |
(( |
(( |
---- |
(( chromous salts (as Cr) |
|||||
Chromium | ---- | ---- | ---- | ---- | ---- |
Chromium (VI) compounds (as Cr) (when the compound is covered by |
---- | (( |
(( |
---- | ---- |
Chromium metal (( or Chromium (II) compounds Or Chromium (III) compounds |
7440-47-3 | 0.5 mg/m3 | (( |
---- | ---- |
Chromyl chloride (as Cr) (see WAC 296-62-08003) |
14977-61-8 | (( |
(( |
---- | ---- |
Chrysene (Coal tar pitch volatiles) |
65996-93-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Chrysotile (as asbestos) (see WAC 296-62-077 and chapter 296-65 WAC) |
---- | 0.1 f/cc | 1.0 f/cc (30 minutes) | ---- | ---- |
Clopidol | 2971-90-6 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Coal dust (less than 5% SiO2) | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | ---- | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Coal dust (greater than or equal to 5% SiO2) |
---- | ---- | ---- | ---- | ---- |
Respirable fraction | ---- | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Coal tar pitch volatiles (benzene soluble fraction) (( aromatic hydrocarbons))) Acridine Anthracene Benzo (a) pyrene Chrysene Phenanthrene Pyrene |
65996-93-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Cobalt, metal fume & dust (as Co) |
7440-48-4 | 0.05 mg/m3 | 0.15 mg/m3 | ---- | ---- |
Cobalt carbonyl (as Co) | 10210-68-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Cobalt hydrocarbonyl (as Co) | 16842-03-8 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Coke oven emissions (see WAC 296-62-200) |
---- | 0.15 mg/m3 | ---- | ---- | ---- |
Copper (as Cu) | 7440-50-8 | ---- | ---- | ---- | ---- |
Fume | ---- | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Dusts and mists | ---- | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Cotton dust (raw) (waste sorting, blending, cleaning, willowing and garetting) (see WAC 296-62-14533) | ---- | 1 mg/m3 | ---- | ---- | ---- |
Corundum (Aluminum oxide) | 7429-90-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Crag herbicide (Sesone, Sodium-2, 4-dichloro-phenoxyethyl sulfate) |
136-78-7 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Cresol (all isomers) | 1319-77-3 | 5 ppm | 10 ppm | ---- | X |
Crocidolite (as asbestos) (see WAC 296-62-077 and |
---- | 0.1 f/cc | 1.0 f/cc (30 minutes) | ---- | ---- |
Crotonaldehyde
|
123-73-9; 4170-30-3 |
2 ppm | 4 ppm | ---- | ---- |
Crufomate | 299-86-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Cumene | 98-82-8 | 50 ppm | 75 ppm | ---- | X |
Cyanamide | 420-04-2 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Cyanide (as CN) | Varies with compound |
5 mg/m3 | 10 mg/m3 | ---- | X |
Cyanogen | 460-19-5 | 10 ppm | 20 ppm | ---- | ---- |
Cyanogen chloride | 506-77-4 | ---- | ---- | 0.3 ppm | ---- |
Cyclohexane | 110-82-7 | 300 ppm | 375 ppm | ---- | ---- |
Cyclohexanol | 108-93-0 | 50 ppm | 75 ppm | ---- | X |
Cyclohexanone | 108-94-1 | 25 ppm | 38 ppm | ---- | X |
Cyclohexene | 110-83-8 | 300 ppm | 375 ppm | ---- | ---- |
Cyclohexylamine | 108-91-8 | 10 ppm | 20 ppm | ---- | ---- |
Cyclonite (RDX) | 121-82-4 | 1.5 mg/m3 | 3.0 mg/m3 | ---- | X |
Cyclopentadiene | 542-92-7 | 75 ppm | 113 ppm | ---- | ---- |
Cyclopentane | 287-92-3 | 600 ppm | 750 ppm | ---- | ---- |
Cyhexatin (Tricyclohexyltin hydroxide) |
13121-70-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
2,4-D (Dichlorophenoxy- acetic acid) |
94-75-7 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
DBCP (1,2-Dibromo-3- chloropropane) (See WAC 296-62-07342) |
96-12-8 | 0.001 ppm | ---- | 0.005 ppm | ---- |
DDT (Dichlorodiphenyltri- chloroethane) |
50-29-3 | 1 mg/m3 | 3 mg/m3 | ---- | X |
DDVP, (Dichlorvos) | 62-73-7 | 0.1 ppm | 0.3 ppm | ---- | X |
Dasanit (Fensulfothion) |
115-90-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Decaborane | 17702-41-9 | 0.05 ppm | 0.15 ppm | ---- | X |
Demeton | 8065-48-3 | 0.01 ppm | 0.03 ppm | ---- | X |
Diacetone alcohol (4-hydroxy-4-methyl- 2-pentanone) |
123-42-2 | 50 ppm | 75 ppm | ---- | ---- |
1, 2-Diaminoethane (Ethylenediamine) |
107-15-3 | 10 ppm | 20 ppm | ---- | ---- |
Diazinon | 333-41-5 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Diazomethane | 334-88-3 | 0.2 ppm | 0.6 ppm | ---- | ---- |
Diborane | 19287-45-7 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Dibrom (see Naled) | 300-76-5 | 3 mg/m3 | 6 mg/m3 | ---- | X |
1, 2-Dibromo-3-chloropropane (DBCP) (see WAC 296-62-07342) |
96-12-8 | 0.001 ppm | ---- | 0.005 ppm | ---- |
2-N-Dibutylamino ethanol | 102-81-8 | 2 ppm | 4 ppm | ---- | X |
Dibutyl phosphate | 107-66-4 | 1 ppm | 2 ppm | ---- | ---- |
Dibutyl phthalate | 84-74-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Dichloroacetylene | 7572-29-4 | ---- | ----- | 0.1 ppm | ---- |
o-Dichlorobenzene | 95-50-1 | ---- | ---- | 50 ppm | ---- |
p-Dichlorobenzene | 106-46-7 | 75 ppm | 110 ppm | ---- | ---- |
3, 3'-Dichlorobenzidine (see WAC 296-62-073) |
91-94-1 | ---- | ---- | ---- | ---- |
Dichlorodiphenyltri- chloroethane (DDT) |
50-29-3 | 1 mg/m3 | 3 mg/m3 | ---- | X |
Dichlorodifluoromethane | 75-71-8 | 1,000 ppm | 1,250 ppm | ---- | ---- |
1, 3-Dichloro-5, 5-dimethyl hydantoin |
118-52-5 | 0.2 mg/m3 | 0.4 mg/m3 | ---- | ---- |
1, 1-Dichloroethane (Ethylidine chloride) |
75-34-3 | 100 ppm | 150 ppm | ---- | ---- |
1, 2-Dichloroethane (Ethylene dichloride) |
107-06-2 | 1 ppm | 2 ppm | ---- | ---- |
1, 1-Dichloroethylene (Vinylidene chloride) |
75-35-4 | 1 ppm | 3 ppm | ---- | ---- |
1, 2-Dichloroethylene (Acetylene dichloride) |
540-59-0 | 200 ppm | 250 ppm | ---- | ---- |
Dichloroethyl ether | 111-44-4 | 5 ppm | 10 ppm | ---- | X |
Dichlorofluoromethane | 75-43-4 | 10 ppm | 20 ppm | ---- | ---- |
Dichloromethane (Methylene chloride) (See (( |
75-09-2 | 25 ppm | 125 ppm | ---- | ---- |
1, 1-Dichloro-1-nitroethane | 594-72-9 | 2 ppm | 10 ppm | ---- | ---- |
Dichlorophenoxyacetic acid (2, 4-D) |
94-75-7 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
1, 2-Dichloropropane (Propylene dichloride) |
78-87-5 | 75 ppm | 110 ppm | ---- | ---- |
Dichloropropene | 542-75-6 | 1 ppm | 3 ppm | ---- | X |
2, 2-Dichloropropionic acid | 75-99-0 | 1 ppm | 3 ppm | ---- | ---- |
Dichlorotetrafluoroethane | 76-14-2 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Dichlorvos (DDVP) | 62-73-7 | 0.1 ppm | 0.3 ppm | ---- | X |
Dicrotophos | 141-66-2 | 0.25 mg/m3 | 0.75 mg/m3 | ---- | X |
Dicyclopentadiene | 77-73-6 | 5 ppm | 10 ppm | ---- | ---- |
Dicyclopentadienyl iron | 102-54-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Dieldrin | 60-57-1 | 0.25 mg/m3 | 0.75 mg/m3 | ---- | X |
Diethanolamine | 111-42-2 | 3 ppm | 6 ppm | ---- | ---- |
Diethylamine | 109-89-7 | 10 ppm | 25 ppm | ---- | ---- |
2-Diethylaminoethanol | 100-37-8 | 10 ppm | 20 ppm | ---- | X |
Diethylene triamine | 111-40-0 | 1 ppm | 3 ppm | ---- | X |
Diethyl ether (Ethyl ether) | 60-29-7 | 400 ppm | 500 ppm | ---- | ---- |
Diethyl ketone | 96-22-0 | 200 ppm | 250 ppm | ---- | ---- |
Diethyl phthalate | 84-66-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Difluorodibromomethane | 75-61-6 | 100 ppm | 150 ppm | ---- | ---- |
Difolatan (Captafol) | 2425-06-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Diglycidyl ether (DGE) | 2238-07-5 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Dihydroxybenzene (Hydroquinone) |
123-31-9 | 2 mg/m3 | 4 mg/m3 | -- -- | ---- |
Diisobutyl ketone (2, 6- Dimethylheptanone) |
108-83-8 | 25 ppm | 38 ppm | ---- | ---- |
Diisopropylamine | 108-18-9 | 5 ppm | 10 ppm | ---- | X |
Dimethoxymethane (Methylal) | 109-87-5 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Dimethyl acetamide | 127-19-5 | 10 ppm | 20 ppm | ---- | X |
Dimethylamine | 124-40-3 | 10 ppm | 20 ppm | ---- | ---- |
4-Dimethylaminoazo benzene (see WAC 296-62-073) |
60-11-7 | ---- | ---- | ---- | ---- |
Dimethylaminobenzene (Xylidene) |
1300-73-8 | 2 ppm | 4 ppm | ---- | X |
Dimethylaniline (N, N-Dimethylaniline) |
121-69-7 | 5 ppm | 10 ppm | ---- | X |
Dimethylbenzene (Xylene) | 1300-73-8 | 100 ppm | 150 ppm | ---- | ---- |
Dimethyl-1, 2-dibromo-2, 2-dichloroethyl phosphate (Naled) |
300-76-5 | 3 mg/m3 | 6 mg/m3 | ---- | X |
Dimethylformamide | 68-12-2 | 10 ppm | 20 ppm | ---- | X |
2, 6-Dimethylheptanone (Diisobutyl ketone) |
108-83-8 | 25 ppm | 38 ppm | ---- | ---- |
1, 1-Dimethylhydrazine | 57-14-7 | 0.5 ppm | 1.5 ppm | ---- | X |
Dimethyl phthalate | 131-11-3 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Dimethyl sulfate | 77-78-1 | 0.1 ppm | 0.3 ppm | ---- | X |
Dinitolmide (3, 5-Dinitro-o-toluamide) |
148-01-6 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Dinitrobenzene (all isomers - alpha, meta and para) |
528-29-0; 99-65-0; 100-25-4 |
0.15 ppm | 0.45 ppm | ---- | X |
Dinitro-o-cresol | 534-52-1 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
3, 5-Dinitro-o-toluamide (Dinitolmide) |
148-01-6 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Dinitrotoluene | 25321-14-6 | 1.5 mg/m3 | 3 mg/m3 | ---- | X |
Dioxane (Diethylene dioxide) | 123-91-1 | 25 ppm | 38 ppm | ---- | X |
Dioxathion | 78-34-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Diphenyl (Biphenyl) | 92-52-4 | 0.2 ppm | 0.6 ppm | ---- | ---- |
Diphenylamine | 122-39-4 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Diphenylmethane diisocyanate (Methylene bisphenyl isocyanate (MDI)) |
101-68-8 | ---- | ---- | 0.02 ppm | ---- |
Dipropylene glycol methyl ether | 34590-94-8 | 100 ppm | 150 ppm | ---- | X |
Dipropyl ketone | 123-19-3 | 50 ppm | 75 ppm | ---- | ---- |
Diquat | 85-00-7 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Di-sec, Octyl phthalate (Di-2-ethylhexylphthalate) |
117-81-7 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Disulfram | 97-77-8 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Disulfoton | 298-04-4 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
2, 6-Di-tert-butyl-p-cresol | 128-37-0 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Diuron | 330-54-1 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Divinyl benzene | 1321-74-0 | 10 ppm | 20 ppm | ---- | ---- |
Emery | 12415-34-8 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Endosulfan (Thiodan) | 115-29-7 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Endrin | 72-20-8 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Epichlorhydrin (1-Chloro-2, 3-epoxypropane) |
106-89-8 | 2 ppm | 4 ppm | ---- | X |
EPN | 2104-64-5 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
1, 2-Epoxypropane (Propylene oxide) |
75-56-9 | 20 ppm | 30 ppm | ---- | ---- |
2, 3-Epoxy-1-propanol (Glycidol) |
556-52-5 | 25 ppm | 38 ppm | ---- | ---- |
Ethane | ---- | Simple asphyxiant | ---- | ---- | ---- |
Ethanethiol (Ethyl mercaptan) |
75-08-1 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Ethanol (Ethyl alcohol) |
64-17-5 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Ethanolamine (2-Aminoethanol) | 141-43-5 | 3 ppm | 6 ppm | ---- | ---- |
Ethion | 563-12-2 | 0.4 mg/m3 | 1.2 mg/m3 | ---- | X |
2-Ethoxyethanol (Glycol monoethyl ether) |
110-80-5 | 5 ppm | 10 ppm | ---- | X |
2-Ethoxyethyl acetate (Cellosolve acetate) |
111-15-9 | 5 ppm | 10 ppm | ---- | X |
Ethyl acetate | 141-78-6 | 400 ppm | 500 ppm | ---- | ---- |
Ethyl acrylate | 140-88-5 | 5 ppm | 25 ppm | ---- | X |
Ethyl alcohol (ethanol) | 64-17-5 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Ethylamine | 75-04-07 | 10 ppm | 20 ppm | ---- | ---- |
Ethyl amyl ketone (5-Methyl-3-hepatone) |
541-85-5 | 25 ppm | 38 ppm | ---- | ---- |
Ethyl benzene | 100-41-4 | 100 ppm | 125 ppm | ---- | ---- |
Ethyl bromide | 74-96-4 | 200 ppm | 250 ppm | ---- | ---- |
Ethyl butyl ketone (3-Heptanone) |
106-35-4 | 50 ppm | 75 ppm | ---- | ---- |
Ethyl chloride | 75-00-3 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Ethylene | 74-85-1 | Simple asphyxiant | ---- | ---- | ---- |
Ethylene chlorohydrin (2-Chloroethanol) |
107-07-3 | ---- | ---- | 1 ppm | X |
Ethylenediamine (1,2- Diaminoethane) |
107-15-3 | 10 ppm | 20 ppm | ---- | X |
Ethylene dibromide | 106-93-4 | 0.1 ppm | 0.5 ppm | ---- | ---- |
Ethylene dichloride (1,2-Dichloroethane) |
107-06-2 | 1 ppm | 2 ppm | ---- | ---- |
Ethylene glycol | 107-21-1 | ---- | ---- | 50 ppm | ---- |
Ethylene glycol dinitrate | 628-96-6 | ---- | 0.1 mg/m3 | ---- | X |
Ethylene glycol monomethyl
ether acetate (Methyl cellosolve acetate) |
---- | 5 ppm | 10 ppm | ---- | X |
Ethyleneimine (see WAC 296-62-073) |
151-56-4 | ---- | ---- | ---- | X |
Ethylene oxide (see (( 296-62-07359)) |
75-21-8 | 1 ppm | 5 ppm | ---- | ---- |
Ethyl ether (Diethyl ether) | 60-29-7 | 400 ppm | 500 ppm | ---- | ---- |
Ethyl formate | 109-94-4 | 100 ppm | 125 ppm | ---- | ---- |
Ethylidine chloride (1, 1-Dichloroethane) |
107-06-2 | 1 ppm | 2 ppm | ---- | ---- |
Ethylidene norbornene | 16219-75-3 | ---- | ---- | 5.0 ppm | ---- |
Ethyl mercaptan (Ethanethiol) | 75-08-1 | 0.5 ppm | 1.5 ppm | ---- | ---- |
n-Ethylmorpholine | 100-74-3 | 5 ppm | 10 ppm | ---- | X |
Ethyl sec-amyl ketone (5-methyl-3-heptanone) |
541-85-5 | 25 ppm | 38 ppm | ---- | ---- |
Ethyl silicate | 78-10-4 | 10 ppm | 20 ppm | ---- | ---- |
Fenamiphos | 22224-92-6 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Fensulfothion (Dasanit) | 115-90-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Fenthion | 55-38-9 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Ferbam | ---- | ---- | ---- | ---- | ---- |
Total particulate | 14484-64-1 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Ferrovanadium dust | 12604-58-9 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Fluorides (as F) | Varies with compound |
2.5 mg/m3 | 5 mg/m3 | ---- | ---- |
Fluorine | 7782-41-4 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Fluorotrichloromethane (see Trichlorofluoro methane) |
75-69-4 | ---- | ---- | 1,000 ppm | ---- |
Fonofos | 944-22-9 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Formaldehyde (see (( |
50-00-0 | 0.75 ppm | 2 ppm | ---- | ---- |
Formamide | 75-12-7 | 20 ppm | 30 ppm | ---- | ---- |
Formic acid | 64-18-6 | 5 ppm | 10 ppm | ---- | ---- |
Furadon (carbofuran) |
1563-66-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Furfural | 98-01-1 | 2 ppm | 4 ppm | ---- | X |
Furfuryl alcohol | 98-00-0 | 10 ppm | 15 ppm | ---- | X |
Gasoline | 8006-61-9 | 300 ppm | 500 ppm | ---- | ---- |
Germanium tetrahydride | 7782-65-2 | 0.2 ppm | 0.6 ppm | ---- | ---- |
Glass, fibrous or dust | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
(( |
111-30-8 | ---- | ---- | 0.2 ppm | ---- |
Glycerin mist | 56-81-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Glycidol (2, 3-Epoxy-1-propanol) |
556-52-5 | 25 ppm | 38 ppm | ---- | ---- |
Glycol monoethyl ether (2-Ethoxyethanol) |
110-80-5 | 5 ppm | 10 ppm | ---- | X |
Grain dust (oat, wheat, barley) | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Graphite, natural | 7782-42-5 | ---- | ---- | ---- | ---- |
Respirable particulate | ---- | 2.5 mg/m3 | 5 mg/m3 | ---- | ---- |
Graphite, synthetic | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Guthion (Azinphosmethyl) |
86-50-0 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Gypsum | 13397-24-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Hafnium | 7440-58-6 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Helium | ---- | Simple asphyxiant | ---- | ---- | ---- |
Heptachlor | 76-44-8 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Heptane (n-heptane) | 142-82-5 | 400 ppm | 500 ppm | ---- | ---- |
2-Heptanone (Methyl n-amyl ketone) |
110-43-0 | 50 ppm | 75 ppm | ---- | ---- |
3-Heptanone (Ethyl butyl ketone) |
106-35-4 | 50 ppm | 75 ppm | ---- | ---- |
Hexachlorobutadiene | 87-68-3 | 0.02 ppm | 0.06 ppm | ---- | X |
Hexachlorocyclopentadiene | 77-47-4 | 0.01 ppm | 0.03 ppm | ---- | ---- |
Hexachloroethane | 67-72-1 | 1 ppm | 3 ppm | ---- | X |
Hexachloronaphthalene | 1335-87-1 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Hexafluoroacetone | 684-16-2 | 0.1 ppm | 0.3 ppm | ---- | X |
Hexane | ---- | ---- | ---- | ---- | ---- |
n-hexane | 110-54-3 | 50 ppm | 75 ppm | ---- | ---- |
other isomers | Varies with compound |
500 ppm | 1,000 ppm | ---- | ---- |
2-Hexanone (Methyl-n-butyl ketone) |
591-78-6 | 5 ppm | 10 ppm | ---- | ---- |
Hexone (Methyl isobutyl ketone) |
108-10-1 | 50 ppm | 75 ppm | ---- | ---- |
sec-Hexyl acetate | 108-84-9 | 50 ppm | 75 ppm | ---- | ---- |
Hexylene glycol | 107-41-5 | ---- | ---- | 25 ppm | ---- |
Hydrazine | 302-01-2 | 0.1 ppm | 0.3 ppm | ---- | X |
Hydrogen | ---- | Simple asphyxiant | ---- | ---- | ---- |
Hydrogenated terphenyls | 61788-32-7 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Hydrogen bromide | 10035-10-6 | ---- | ---- | 3.0 ppm | ---- |
Hydrogen chloride | 7647-01-0 | ---- | ---- | 5.0 ppm | ---- |
Hydrogen cyanide | 74-90-8 | ---- | 4.7 ppm | ---- | X |
Hydrogen fluoride | 7664-39-3 | ---- | ---- | 3 ppm | ---- |
Hydrogen peroxide | 7722-84-1 | 1 ppm | 3 ppm | ---- | ---- |
Hydrogen selenide (as Se) | 7783-07-5 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Hydrogen sulfide | 7783-06-4 | 10 ppm | 15 ppm | ---- | ---- |
Hydroquinone (Dihydroxybenzene) |
123-31-9 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
4-Hydroxy-4-methyl-2-pentanone (Diacetone alcohol) |
123-42-2 | 50 ppm | 75 ppm | ---- | ---- |
2-Hydroxypropyl acrylate | 99-61-1 | 0.5 ppm | 1.5 ppm | ---- | X |
Indene | 95-13-6 | 10 ppm | 20 ppm | ---- | ---- |
Indium and compounds (as In) | 7440-74-6 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Iodine | 7553-56-2 | ---- | ---- | 0.1 ppm | ---- |
Iodoform | 75-47-8 | 0.6 ppm | 1.8 ppm | ---- | ---- |
Iron oxide dust and fume (as Fe) | 1309-37-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Iron pentacarbonyl (as Fe) | 13463-40-6 | 0.1 ppm | 0.2 ppm | ---- | ---- |
Iron salts, soluble (as Fe) | Varies with compound |
1 mg/m3 | 3 mg/m3 | ---- | ---- |
Isoamyl acetate | 123-92-2 | 100 ppm | 150 ppm | ---- | ---- |
Isoamyl alcohol (primary and secondary) |
123-51-3 | 100 ppm | 125 ppm | ---- | ---- |
Isobutyl acetate | 110-19-0 | 150 ppm | 188 ppm | ---- | ---- |
Isobutyl alcohol | 78-83-1 | 50 ppm | 75 ppm | ---- | ---- |
Isooctyl alcohol | 26952-21-6 | 50 ppm | 75 ppm | ---- | X |
Isophorone | 78-59-1 | 4 ppm | ---- | 5 ppm | ---- |
Isophorone diisocyanate | 4098-71-9 | 0.005 ppm | 0.02 ppm | ---- | X |
Isopropoxyethanol | 109-59-1 | 25 ppm | 38 ppm | ---- | ---- |
Isopropyl acetate | 108-21-4 | 250 ppm | 310 ppm | ---- | ---- |
Isopropyl alcohol | 67-63-0 | 400 ppm | 500 ppm | ---- | ---- |
Isopropylamine | 75-31-0 | 5 ppm | 10 ppm | ---- | ---- |
N-Isopropylaniline | 768-52-5 | 2 ppm | 4 ppm | ---- | X |
Isopropyl ether | 108-20-3 | 250 ppm | 313 ppm | ---- | ---- |
Isopropyl glycidyl ether (IGE) | 4016-14-2 | 50 ppm | 75 ppm | ----- | ---- |
Kaolin | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Ketene | 463-51-4 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
Lannate (Methomyl) |
16752-77-5 | 2.5 mg/m3 | 5 mg/m3 | ---- | ---- |
Lead, inorganic (as Pb) (see WAC 296-62-07521 and 296-155-176) |
7439-92-1 | 0.05 mg/m3 | ---- | ---- | ---- |
Lead arsenate (as Pb) (see WAC (( 296-62-07521, 296-155-176, and chapter 296-848 WAC) |
3687-31-8 | 0.05 mg/m3 | ---- | ---- | ---- |
Lead chromate (as Pb) (see WAC 296-62-08003, 296-62-07521, and 296-155-176) |
7758-97-6 | 0.05 mg/m3 | ---- | ---- | ---- |
Limestone | 1317-65-3 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Lindane | 58-89-9 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Lithium hydride | 7580-67-8 | 0.025 mg/m3 | 0.075 mg/m3 | ---- | ---- |
L.P.G. (liquified petroleum gas) |
68476-85-7 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Magnesite | 546-93-0 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Magnesium oxide fume | 1309-48-4 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Malathion | 121-75-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | X |
Maleic anhydride | 108-31-6 | 0.25 ppm | 0.75 ppm | ---- | ---- |
Manganese and compounds (as Mn) | 7439-96-5 | ---- | ---- | 5 mg/m3 | ---- |
Manganese cyclopentadienyl tricarbonyl (as Mn) |
12079-65-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Manganese tetroxide and fume (as Mn) |
7439-96-5 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Marble | 1317-65-3 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
MBOCA (4, 4'-Methylene bis (2-chloro-aniline)) (see WAC 296-62-073) |
101-14-4 | ---- | ---- | ---- | X |
MDA (4, 4-Methylene dianiline) (see WAC 296-62-076 and 296-155-173) |
101-77-9 | 0.01 ppm | 0.1 ppm | ---- | X |
MDI (Methylene bisphenyl isocyanate) (Diphenylmethane diisocyanate) |
101-68-8 | ---- | ---- | 0.02 ppm | ---- |
MEK (Methyl ethyl ketone) (2-Butanone) |
78-93-3 | 200 ppm | 300 ppm | ---- | ---- |
MEKP (Methyl ethyl ketone peroxide) |
1338-23-4 | ---- | ---- | 0.2 ppm | ---- |
Mercury (as Hg) | 7439-97-6 | ---- | ---- | ---- | ---- |
Aryl and inorganic | ---- | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Organo-alkyl compounds | ---- | 0.01 mg/m3 | 0.03 mg/m3 | ---- | X |
Vapor | ---- | 0.05 mg/m3 | 0.15 mg/m3 | ---- | X |
Mesityl oxide | 141-79-7 | 15 ppm | 25 ppm | ---- | ---- |
Methacrylic acid | 79-41-4 | 20 ppm | 30 ppm | ---- | X |
Methane | ---- | Simple asphyxiant | ---- | ---- | ---- |
Methanethiol (Methyl mercaptan) |
74-93-1 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Methanol (Methyl alcohol) |
67-56-1 | 200 ppm | 250 ppm | ---- | X |
Methomyl (lannate) | 16752-77-5 | 2.5 mg/m3 | 5 mg/m3 | ---- | ---- |
Methoxychlor | 72-43-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
2-Methoxyethanol (Methyl cellosolve) |
109-86-4 | 5 ppm | 10 ppm | ---- | X |
2-Methoxyethyl acetate (Methyl cellosolve acetate) |
110-49-6 | 5 ppm | 10 ppm | ---- | X |
4-Methoxyphenol | 150-76-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Methyl acetate | 79-20-9 | 200 ppm | 250 ppm | ---- | ---- |
Methyl acetylene (propyne) | 74-99-7 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Methyl acetylene-propadiene mixture (MAPP) |
---- | 1,000 ppm | 1,250 ppm | ---- | ---- |
Methyl acrylate | 96-33-3 | 10 ppm | 20 ppm | ---- | X |
Methylacrylonitrile | 126-98-7 | 1 ppm | 3 ppm | ---- | X |
Methylal (Dimethoxy-methane) | 109-87-5 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Methyl alcohol (methanol) | 67-56-1 | 200 ppm | 250 ppm | ---- | X |
Methylamine | 74-89-5 | 10 ppm | 20 ppm | ---- | ---- |
Methyl amyl alcohol (Methyl isobutyl carbinol) |
108-11-2 | 25 ppm | 40 ppm | ---- | X |
Methyl n-amyl ketone (2-Heptanone) |
110-43-0 | 50 ppm | 75 ppm | ---- | ---- |
N-Methyl aniline (Monomethyl aniline) |
100-61-8 | 0.5 ppm | 1.5 ppm | ---- | X |
Methyl bromide | 74-83-9 | 5 ppm | 10 ppm | ---- | X |
Methyl-n-butyl ketone (2-Hexanone) |
591-78-6 | 5 ppm | 10 ppm | ---- | ---- |
Methyl cellosolve (2-Methoxyethanol) |
109-86-4 | 5 ppm | 10 ppm | ---- | X |
Methyl cellosolve acetate (2-Methoxyethyl acetate) |
110-49-6 | 5 ppm | 10 ppm | ---- | X |
Methyl chloride | 74-87-3 | 50 ppm | 100 ppm | ---- | ---- |
Methyl chloroform (1, 1, 1-trichlorethane) |
71-55-6 | 350 ppm | 450 ppm | ---- | ---- |
Methyl chloromethyl ether (chloromethyl methyl ether) (see WAC 296-62-073) |
107-30-2 | ---- | ---- | ---- | ---- |
Methyl 2-cyanoacrylate | 137-05-3 | 2 ppm | 4 ppm | ---- | ---- |
Methylcyclohexane | 108-87-2 | 400 ppm | 500 ppm | ---- | ---- |
Methylcyclohexanol | 25639-42-3 | 50 ppm | 75 ppm | ---- | ---- |
Methylcyclohexanone | 583-60-8 | 50 ppm | 75 ppm | ---- | X |
Methylcyclopentadienyl manganese tricarbonyl (as Mn) |
12108-13-3 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Methyl demeton | 8022-00-2 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Methylene bisphenyl isocyanate (MDI) (Diphenylmethane diisocyanate) |
101-68-8 | ---- | ---- | 0.02 ppm | ---- |
4, 4'-Methylene bis (2-chloro-aniline) (MBOCA) (see WAC 296-62-073) |
101-14-4 | ---- | ---- | ---- | X |
Methylene bis (4-cyclohexylisocyanate) |
5124-30-1 | ---- | ---- | 0.01 ppm | ---- |
Methylene chloride (Dichloromethane) (see (( |
75-09-2 | 25 ppm | 125 ppm | ---- | ---- |
4, 4-Methylene dianiline (MDA) (see WAC 296-62-076 and 296-155-173) |
101-77-9 | 0.01 ppm | 0.1 ppm | ---- | X |
Methyl ethyl ketone (MEK) (2-Butanone) |
78-93-3 | 200 ppm | 300 ppm | ---- | ---- |
Methyl ethyl ketone peroxide (MEKP) |
1338-23-4 | ---- | ---- | 0.2 ppm | ---- |
Methyl formate | 107-31-3 | 100 ppm | 150 ppm | ---- | ---- |
5-Methyl-3-heptanone (Ethyl amyl ketone) |
541-85-5 | 25 ppm | 38 ppm | ---- | ---- |
Methyl hydrazine (Monomethyl hydrazine) |
60-34-4 | ---- | ---- | 0.2 ppm | X |
Methyl iodide | 74-88-4 | 2 ppm | 4 ppm | ---- | X |
Methyl isoamyl ketone | 110-12-3 | 50 ppm | 75 ppm | ---- | ---- |
Methyl isobutyl carbinol (Methyl amyl alcohol) |
108-11-2 | 25 ppm | 40 ppm | ---- | X |
Methyl isobutyl ketone (Hexone) |
108-10-1 | 50 ppm | 75 ppm | ---- | ---- |
Methyl isocyanate | 624-83-9 | 0.02 ppm | 0.06 ppm | ---- | X |
Methyl isopropyl ketone | 563-80-4 | 200 ppm | 250 ppm | ---- | ---- |
Methyl mercaptan (Methanethiol) | 74-93-1 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Methyl methacrylate | 80-62-6 | 100 ppm | 150 ppm | ---- | ---- |
Methyl parathion | 298-00-0 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Methyl propyl ketone (2-Pentanone) |
107-87-9 | 200 ppm | 250 ppm | ---- | ---- |
Methyl silicate | 684-84-5 | 1 ppm | 3 ppm | ---- | ---- |
alpha-Methyl styrene | 98-83-9 | 50 ppm | 100 ppm | ---- | ---- |
Mevinphos (Phosdrin) | 7786-34-7 | 0.01 ppm | 0.03 ppm | ---- | X |
Metribuzin | 21087-64-9 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Mica (Silicates) Respirable fraction |
12001-26-2 | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Molybdenum (as Mo) | 7439-98-7 | ---- | ---- | ---- | ---- |
Soluble compounds | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Insoluble compounds | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Monochlorobenzene (Chlorobenzene) |
108-90-7 | 75 ppm | 113 ppm | ---- | ---- |
Monocrotophos (Azodrin) | 6923-22-4 | 0.25 mg/m3 | 0.75 mg/m3 | ---- | ---- |
Monomethyl aniline (N-Methyl aniline) |
100-61-8 | 0.5 ppm | 1.5 ppm | ---- | X |
Monomethyl hydrazine | ---- | ---- | ---- | 0.2 ppm | ---- |
Morpholine | 110-91-8 | 20 ppm | 30 ppm | ---- | X |
Naled (Dibrom) | 300-76-5 | 3 mg/m3 | 6 mg/m3 | ---- | X |
Naphtha | 8030-30-6 | 100 ppm | 150 ppm | ---- | X |
Naphthalene | 91-20-3 | 10 ppm | 15 ppm | ---- | ---- |
alpha-Naphthylamine (see WAC 296-62-073) |
134-32-7 | ---- | ---- | ---- | ---- |
beta-Naphthylamine (see WAC 296-62-073) |
91-59-8 | ---- | ---- | ---- | ---- |
Neon | 7440-01-9 | Simple asphyxiant | ---- | ---- | ---- |
Nickel carbonyl (as Ni) | 13463-39-3 | 0.001 ppm | 0.003 ppm | ---- | ---- |
Nickel (as Ni) | 7440-02-0 | ---- | ---- | ---- | ---- |
Metal and insoluble compounds |
---- | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Soluble compounds | ---- | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Nicotine | 54-11-5 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Nitrapyrin (2-Chloro-6 trichloromethyl pyridine) |
1929-82-4 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Nitric acid | 7697-37-2 | 2 ppm | 4 ppm | ---- | ---- |
Nitric oxide | 10102-43-9 | 25 ppm | 38 ppm | ---- | ---- |
p-Nitroaniline | 100-01-6 | 3 mg/m3 | 6 mg/m3 | ---- | X |
Nitrobenzene | 98-95-3 | 1 ppm | 3 ppm | ---- | X |
4-Nitrobiphenyl (see WAC 296-62-073) |
92-93-3 | ---- | ---- | ---- | ---- |
p-Nitrochlorobenzene | 100-00-5 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
4-Nitrodiphenyl (see WAC 296-62-073) |
---- | ---- | ---- | ---- | ---- |
Nitroethane | 79-24-3 | 100 ppm | 150 ppm | ---- | ---- |
Nitrogen | 7727-37-9 | Simple asphyxiant | ---- | ---- | ---- |
Nitrogen dioxide | 10102-44-0 | ---- | 1 ppm | ---- | ---- |
Nitrogen oxide (Nitrous oxide) |
10024-97-2 | 50 ppm | 75 ppm | ---- | ---- |
Nitrogen trifluoride | 7783-54-2 | 10 ppm | 20 ppm | ---- | ---- |
Nitroglycerin | 55-63-0 | ---- | 0.1 mg/m3 | ---- | X |
Nitromethane | 75-52-5 | 100 ppm | 150 ppm | ---- | ---- |
1-Nitropropane | 108-03-2 | 25 ppm | 38 ppm | ---- | ---- |
2-Nitropropane | 79-46-9 | 10 ppm | 20 ppm | ---- | ---- |
N-Nitrosodimethylamine (see WAC 296-62-073) |
62-75-9 | ---- | ---- | ---- | ---- |
Nitrotoluene | ---- | ---- | ---- | ---- | ---- |
o-isomer | 88-72-2 | 2 ppm | 4 ppm | ---- | X |
m-isomer | 98-08-2 | 2 ppm | 4 ppm | ---- | X |
p-isomer | 99-99-0 | 2 ppm | 4 ppm | ---- | X |
Nitrotrichloromethane (Chloropicrin) |
76-06-2 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Nitrous oxide (Nitrogen oxide) |
10024-97-2 | 50 ppm | 75 ppm | ---- | ---- |
Nonane | 111-84-2 | 200 ppm | 250 ppm | ---- | ---- |
Nuisance dusts (see Particulates not otherwise regulated) | ---- | ---- | ---- | ---- | ---- |
Octachloronaphthalene | 2234-13-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Octane | 111-65-9 | 300 ppm | 375 ppm | ---- | ---- |
Oil mist mineral (particulate) | 8012-95-1 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Osmium tetroxide (as Os) | 20816-12-0 | 0.0002 ppm | 0.0006 ppm | ---- | ---- |
Oxalic acid | 144-62-7 | 1 mg/m3 | 2 mg/m3 | ---- | ---- |
Oxygen See requirements in other chapters such as: Confined spaces; chapter 296-843 WAC, Hazardous waste operations; chapter 296-824 WAC, Emergency response; WAC 296-62-100, Oxygen deficient atmospheres |
---- | ---- | ---- | ---- | ---- |
Oxygen difluoride | 7783-41-7 | ---- | ---- | 0.05 ppm | ---- |
Ozone | 10028-15-6 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Paper fiber (Cellulose) |
9004-34-6 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Paraffin wax fume | 8002-74-2 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Paraquat | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 4685-14-7 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
1910-42-5 | |||||
2074-50-2 | |||||
Parathion | 56-38-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Particulate polycyclic aromatic hydrocarbons (( (see coal tar pitch volatiles) |
(( |
---- | ---- | ||
Particulates not otherwise regulated |
---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pentaborane | 19624-22-7 | 0.005 ppm | 0.015 ppm | ---- | ---- |
Pentachloronaphthalene | 1321-64-8 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Pentachlorophenol | 87-86-5 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Pentaerythritol | 115-77-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pentane | 109-66-0 | 600 ppm | 750 ppm | ---- | ---- |
2-Pentanone (methyl propyl ketone) |
107-87-9 | 200 ppm | 250 ppm | ---- | ---- |
Perchloroethylene (tetrachloroethylene) |
127-18-4 | 25 ppm | 38 ppm | ---- | ---- |
Perchloromethyl mercaptan | 594-42-3 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Perchloryl fluoride | 7616-94-6 | 3 ppm | 6 ppm | ---- | ---- |
Perlite | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Petroleum distillates (Naptha, rubber solvent) |
---- | 100 ppm | 150 ppm | ---- | ---- |
Phenacyl chloride (a-Chloroacetophenone) |
532-21-4 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Phenol | 108-95-2 | 5 ppm | 10 ppm | ---- | X |
Phenothiazine | 92-84-2 | 5 mg/m3 | 10 mg/m3 | ---- | X |
p-Phenylene diamine | 106-50-3 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Phenyl ether (vapor) | 101-84-8 | 1 ppm | 3 ppm | ---- | ---- |
Phenyl ether-diphenyl mixture (vapor) |
---- | 1 ppm | 3 ppm | ---- | ---- |
Phenylethylene (Styrene) | 100-42-5 | 50 ppm | 100 ppm | ---- | ---- |
Phenyl glycidyl ether (PGE) | 122-60-1 | 1 ppm | 3 ppm | ---- | ---- |
Phenylhydrazine | 100-63-0 | 5 ppm | 10 ppm | ---- | X |
Phenyl mercaptan | 108-98-5 | 0.5 ppm | 1.5 ppm | ---- | ---- |
Phenylphosphine | 638-21-1 | ---- | ---- | 0.05 ppm | ---- |
Phorate | 298-02-2 | 0.05 mg/m3 | 0.2 mg/m3 | ---- | X |
Phosdrin (Mevinphos) | 7786-34-7 | 0.01 ppm | 0.03 ppm | ---- | X |
Phosgene (carbonyl chloride) | 75-44-5 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Phosphine | 7803-51-2 | 0.3 ppm | 1 ppm | ---- | ---- |
Phosphoric acid | 7664-38-2 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Phosphorus (yellow) | 7723-14-0 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Phosphorous oxychloride | 10025-87-3 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Phosphorus pentachloride | 10026-13-8 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Phosphorus pentasulfide | 1314-80-3 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Phosphorus trichloride | 12-2-19 | 0.2 ppm | 0.5 ppm | ---- | ---- |
Phthalic anhydride | 85-44-9 | 1 ppm | 3 ppm | ---- | ---- |
m-Phthalodinitrile | 626-17-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Picloram | 1918-02-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Picric acid (2, 4, 6- Trinitrophenol) |
88-89-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Pindone (2-Pivalyl-1, 3-indandione, Pival) |
83-26-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Piperazine dihydrochloride | 142-64-3 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pival (Pindone) | 83-26-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Plaster of Paris | 26499-65-0 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Platinum (as Pt) | 7440-06-4 | ---- | ---- | ---- | ---- |
Metal | ---- | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Soluble salts | ---- | 0.002 mg/m3 | 0.006 mg/m3 | ---- | ---- |
Polychlorobiphenyls (Chlorodiphenyls) |
---- | ---- | ---- | ---- | ---- |
42% Chlorine (PCB) | 53469-21-9 | 1 mg/m3 | 3 mg/m3 | ---- | X |
54% Chlorine (PCB) | 11097-69-1 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Portland cement | 65997-15-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Potassium hydroxide | 1310-58-3 | ---- | ---- | 2 mg/m3 | ---- |
Propane | 74-98-6 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Propargyl alcohol | 107-19-7 | 1 ppm | 3 ppm | ---- | X |
beta-Propiolactone (see WAC 296-62-073) |
57-57-8 | ---- | ---- | ---- | ---- |
Propionic acid | 79-09-4 | 10 ppm | 20 ppm | ---- | ---- |
Propoxur (Baygon) | 114-26-1 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | ---- |
n-Propyl acetate | 109-60-4 | 200 ppm | 250 ppm | ---- | ---- |
n-Propyl alcohol | 71-23-8 | 200 ppm | 250 ppm | ---- | X |
n-Propyl nitrate | 627-13-4 | 25 ppm | 40 ppm | ---- | ---- |
Propylene | ---- | Simple asphyxiant | ---- | ---- | ---- |
Propylene dichloride (1, 2-Dichloropropane) |
78-87-5 | 75 ppm | 110 ppm | ---- | ---- |
Propylene glycol dinitrate | 6423-43-4 | 0.05 ppm | 0.15 ppm | ---- | X |
Propylene glycol monomethyl ether |
107-98-2 | 100 ppm | 150 ppm | ---- | ---- |
Propylene imine | 75-55-8 | 2 ppm | 4 ppm | ---- | X |
Propylene oxide (1,2- Epoxypropane) |
75-56-9 | 20 ppm | 30 ppm | ---- | ---- |
Propyne (Methyl acetylene) | 74-99-7 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Pyrethrum | 8003-34-7 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Pyridine | 110-86-1 | 5 ppm | 10 ppm | ---- | ---- |
Pyrocatachol (Catechol) |
120-80-9 | 5 ppm | 10 ppm | ---- | X |
Quinone (p-Benzoquinone) | 106-51-4 | 0.1 ppm | 0.3 ppm | ---- | ---- |
RDX (Cyclonite) | ---- | 1.5 mg/m3 | 3 mg/m3 | ---- | X |
Resorcinol | 108-46-3 | 10 ppm | 20 ppm | ---- | ---- |
Rhodium (as Rh) | 7440-16-6 | ---- | ---- | ---- | ---- |
Insoluble compounds, metal fumes and dusts |
---- | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Soluble compounds, salts | ---- | 0.001 mg/m3 | 0.003 mg/m3 | ---- | ---- |
Ronnel | 299-84-3 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Rosin core solder, pyrolysis products (as formaldehyde) |
8050-09-7 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Rotenone | 83-79-4 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Rouge | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Rubber solvent (naphtha) | 8030-30-6 | 100 ppm | 150 ppm | ---- | ---- |
Selenium compounds (as Se) | 7782-49-2 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
Selenium hexafluoride (as Se) | 7783-79-1 | 0.05 ppm | 0.15 ppm | ---- | ---- |
Sesone (Crag herbicide) | 136-78-7 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Sevin (Carbaryl) |
63-25-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Silane (see Silicon tetrahydride) | 7803-62-5 | 5 ppm | 10 ppm | ---- | ---- |
Silica, amorphous, precipitated and gel |
112926-00-8 | 6 mg/m3 | 12 mg/m3 | ---- | ---- |
Silica, amorphous, diatomaceous earth, containing less than 1% crystalline silica |
61790-53-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 6 mg/m3 | 12 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Silica, crystalline cristobalite | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 14464-46-1 | 0.05 mg/m3 | 0.15 mg/m3 | ---- | ---- |
Silica, crystalline quartz | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 14808-60-7 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Silica, crystalline tripoli (as quartz) |
---- | ---- | ---- | ---- | ---- |
Respirable fraction | 1317-95-9 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Silica, crystalline tridymite | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 15468-32-3 | 0.05 mg/m3 | 0.15 mg/m3 | ---- | ---- |
Silica, fused | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 60676-86-0 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Silicates (less than 1% crystalline silica) | ---- | ---- | ---- | ---- | ---- |
Mica | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 12001-26-2 | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Soapstone | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 6 mg/m3 | 12 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Talc (containing asbestos) (as asbestos) (see WAC 296-62-07705 and |
---- | (( |
(( |
---- | ---- |
Talc (containing no asbestos) |
---- | ---- | ---- | ---- | ---- |
Respirable fraction | 14807-96-6 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Tremolite (asbestiform) (as asbestos) (see WAC 296-62-07705 and chapter 296-65 WAC) |
---- | (( |
(( |
---- | ---- |
Silicon | 7440-21-3 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Silicon carbide | 409-21-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Silicon tetrahydride (Silane) | 7803-62-5 | 5 ppm | 10 ppm | ---- | ---- |
Silver, metal dust and soluble compounds (as Ag) |
7440-22-4 | 0.01 mg/m3 | 0.03 mg/m3 | ---- | ---- |
Soapstone | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 6 mg/m3 | 12 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Sodium azide (as HN3 or NaN3) | 26628-22-8 | ---- | ---- | 0.1 ppm | X |
Sodium bisulfite | 7631-90-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Sodium-2, 4-dichloro- phenoxyethyl sulfate (Crag herbicide) |
136-78-7 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Sodium fluoroacetate | 62-74-8 | 0.05 mg/m3 | 0.15 mg/m3 | ---- | X |
Sodium hydroxide | 1310-73-2 | ---- | ---- | 2 mg/m3 | ---- |
Sodium metabisulfite | 7681-57-4 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Starch | 9005-25-8 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Stibine | 7803-52-3 | 0.1 ppm | 0.3 ppm | ---- | ---- |
Stoddard solvent | 8052-41-3 | 100 ppm | 150 ppm | ---- | ---- |
Strychnine | 57-24-9 | 0.15 mg/m3 | 0.45 mg/m3 | ---- | ---- |
Styrene (Phenylethylene, Vinyl benzene) |
100-42-5 | 50 ppm | 100 ppm | ---- | ---- |
Subtilisins | 9014-01-1 | ---- | 0.00006 mg/m3 | ---- | ---- |
(60 min.) | |||||
Sucrose | 57-50-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Sulfotep (TEDP) | 3689-24-5 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Sulfur dioxide | 7446-09-5 | 2 ppm | 5 ppm | ---- | ---- |
Sulfur hexafluoride | 2551-62-4 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Sulfuric acid | 7664-93-9 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Sulfur monochloride | 10025-67-9 | ---- | ---- | 1 ppm | ---- |
Sulfur pentafluoride | 5714-22-1 | ---- | ---- | 0.01 ppm | ---- |
Sulfur tetrafluoride | 7783-60-0 | ---- | ---- | 0.1 ppm | ---- |
Sulfuryl fluoride | 2699-79-8 | 5 ppm | 10 ppm | ---- | ---- |
Sulprofos | 35400-43-2 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Systox (Demeton) | 8065-48-3 | 0.01 ppm | 0.03 ppm | ---- | X |
2, 4, 5-T (2, 4, 5- tri- chlorophenoxyacetic acid) |
93-76-5 | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Talc (containing asbestos) (as asbestos) (see WAC 296-62-07705 and chapter 296-65 WAC) |
---- | (( |
(( |
---- | ---- |
Talc (containing no asbestos) | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 14807-96-6 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Tantalum | ---- | ---- | ---- | ---- | ---- |
Metal and oxide dusts | 7440-25-7 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
TDI (Toluene-2, 4-diisocyanate) |
584-84-9 | 0.005 ppm | 0.02 ppm | ---- | ---- |
TEDP (Sulfotep) | 3689-24-5 | 0.2 mg/m3 | 0.6 mg/m3 | ---- | X |
Tellurium and compounds (as Te) | 13494-80-9 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Tellurium hexafluoride (as Te) | 7783-80-4 | 0.02 ppm | 0.06 ppm | ---- | ---- |
Temephos (Abate) | 3383-96-8 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
TEPP | 107-49-3 | 0.004 ppm | 0.012 ppm | ---- | X |
Terphenyls | 26140-60-3 | ---- | ---- | 0.5 ppm | ---- |
1, 1, 1, 2-Tetrachloro-2, 2-difluoroethane |
76-11-0 | 500 ppm | 625 ppm | ---- | ---- |
1, 1, 2, 2-Tetrachloro-1, 2-difluoroethane |
76-12-0 | 500 ppm | 625 ppm | ---- | ---- |
1, 1, 2, 2-Tetrachloroethane | 79-34-5 | 1 ppm | 3 ppm | ---- | X |
Tetrachloroethylene (Perchloroethylene) |
127-18-4 | 25 ppm | 38 ppm | ---- | ---- |
Tetrachloromethane (Carbon tetrachloride) |
56-23-5 | 2 ppm | 4 ppm | ---- | X |
Tetrachloronaphthalene | 1335-88-2 | 2 mg/m3 | 4 mg/m3 | ---- | X |
Tetraethyl lead (as Pb) | 78-00-2 | 0.075 mg/m3 | 0.225 mg/m3 | ---- | X |
Tetrahydrofuran | 109-99-9 | 200 ppm | 250 ppm | ---- | ---- |
Tetramethyl lead (as Pb) | 75-74-1 | 0.075 mg/m3 | 0.225 mg/m3 | ---- | X |
Tetramethyl succinonitrile | 3333-52-6 | 0.5 ppm | 1.5 ppm | ---- | X |
Tetranitromethane | 509-14-8 | 1 ppm | 3 ppm | ---- | ---- |
Tetrasodium pyrophosphate | 7722-88-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Tetryl (2, 4, 6-trinitrophenyl- methylnitramine) |
479-45-8 | 1.5 mg/m3 | 3 mg/m3 | ---- | X |
Thallium (soluble compounds) (as Tl) |
7440-28-0 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
4, 4-Thiobis (6-tert-butyl-m-cresol) |
96-69-5 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Thiodan (Endosulfan) |
115-29-7 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Thioglycolic acid | 68-11-1 | 1 ppm | 3 ppm | ----- | X |
Thionyl chloride | 7719-09-7 | ---- | ---- | 1 ppm | ---- |
Thiram (see WAC 296-62-07519) |
137-26-8 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Tin (as Sn) | ---- | ---- | ---- | ---- | ---- |
Inorganic compounds | 7440-31-5 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Tin (as Sn) | ---- | ---- | ---- | ---- | ---- |
Organic compounds | 7440-31-5 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Tin oxide (as Sn) | 21651-19-4 | 2 mg/m3 | 4 mg/m3 | ---- | ---- |
Titanium dioxide | 13463-67-7 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
TNT (2, 4, 6-Trinitrotoluene) |
118-96-7 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Toluene | 108-88-3 | 100 ppm | 150 ppm | ---- | ---- |
Toluene-2, 4-diisocyanate (TDI) | 584-84-9 | 0.005 ppm | 0.02 ppm | ----- | ---- |
m-Toluidine | 108-44-1 | 2 ppm | 4 ppm | ---- | X |
o-Toluidine | 95-53-4 | 2 ppm | 4 ppm | ---- | X |
p-Toluidine | 106-49-0 | 2.0 ppm | 4 ppm | ---- | X |
Toxaphene (Chlorinated camphene) |
8001-35-2 | 0.5 mg/m3 | 1 mg/m3 | ---- | X |
Tremolite (asbestiform) (as asbestos) (see WAC 296-62-07705 and |
---- | (( |
(( |
---- | ---- |
Tributyl phosphate | 126-73-8 | 0.2 ppm | 0.6 ppm | ---- | ---- |
Trichloroacetic acid | 76-03-9 | 1 ppm | 3 ppm | ---- | ---- |
1, 2, 4-Trichlorobenzene | 120-82-1 | ---- | ---- | 5 ppm | ---- |
1, 1, 1-Trichloroethane (Methyl chloroform) |
71-55-6 | 350 ppm | 450 ppm | ---- | ---- |
1, 1, 2-Trichloroethane | 79-00-5 | 10 ppm | 20 ppm | ---- | ---- |
Trichloroethylene | 79-01-6 | 50 ppm | 200 ppm | ---- | ---- |
Trichlorofluoromethane (Fluorotrichloromethane) |
75-69-4 | ---- | ---- | 1,000 ppm | ---- |
Trichloromethane (Chloroform) |
67-66-3 | 2 ppm | 4 ppm | ---- | ---- |
Trichloronaphthalene | 1321-65-9 | 5 mg/m3 | 10 mg/m3 | ---- | X |
1, 2, 3-Trichloropropane | 96-18-4 | 10 ppm | 20 ppm | ---- | X |
1, 1, 2-Trichloro-1, 2, 2-trifluoroethane |
76-13-1 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Tricyclohexyltin hydroxide (Cyhexatin) |
13121-70-5 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Triethylamine | 121-44-8 | 10 ppm | 15 ppm | ---- | ---- |
Trifluorobromomethane | 75-63-8 | 1,000 ppm | 1,250 ppm | ---- | ---- |
Trimellitic anhydride | 552-30-7 | 0.005 ppm | 0.015 ppm | ---- | ---- |
Trimethylamine | 75-50-3 | 10 ppm | 15 ppm | ---- | ---- |
Trimethyl benzene | 25551-13-7 | 25 ppm | 38 ppm | ---- | ---- |
Trimethyl phosphite | 121-45-9 | 2 ppm | 4 ppm | ---- | ---- |
2, 4, 6-Trinitrophenol (Picric acid) |
88-89-1 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
2, 4, 6-Trinitrophenyl- methylnitramine (Tetryl) |
479-45-8 | 1.5 mg/m3 | 3 mg/m3 | ----- | X |
2, 4, 6-Trinitrotoluene (TNT) | 118-96-7 | 0.5 mg/m3 | 1.5 mg/m3 | ---- | X |
Triorthocresyl phosphate | 78-30-8 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | X |
Triphenyl amine | 603-34-9 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Triphenyl phosphate | 115-86-6 | 3 mg/m3 | 6 mg/m3 | ---- | ---- |
Tungsten (as W) | 7440-33-7 | ---- | ---- | ---- | ---- |
Soluble compounds | ---- | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Insoluble compounds | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Turpentine | 8006-64-2 | 100 ppm | 150 ppm | ---- | ---- |
Uranium (as U) | 7440-61-1 | ---- | ---- | ---- | ---- |
Soluble compounds | ---- | 0.05 mg/m3 | 0.15 mg/m3 | ---- | ---- |
Insoluble compounds | ---- | 0.2 mg/m3 | 0.6 mg/m3 | ---- | ---- |
n-Valeraldehyde | 110-62-3 | 50 ppm | 75 ppm | ---- | ---- |
Vanadium (as V2O5) | ---- | ---- | ---- | ---- | ---- |
Respirable fraction | 1314-62-1 | 0.05 mg/m3 | 0.15 mg/m3 | ---- | ---- |
Vegetable oil mist | ---- | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Vinyl acetate | 108-05-1 | 10 ppm | 20 ppm | ---- | ---- |
Vinyl benzene (Styrene) | 100-42-5 | 50 ppm | 100 ppm | ---- | ---- |
Vinyl bromide | 593-60-2 | 5 ppm | 10 ppm | ---- | ---- |
Vinyl chloride (Chloroethylene) (see WAC 296-62-07329) |
75-01-4 | 1 ppm | 5 ppm | ---- | ---- |
Vinyl cyanide (Acrylonitrile) (see WAC 296-62-07336) |
107-13-1 | 2 ppm | 10 ppm | ---- | ---- |
Vinyl cyclohexene dioxide | 106-87-6 | 10 ppm | 20 ppm | ---- | X |
Vinyl toluene | 25013-15-4 | 50 ppm | 75 ppm | ---- | ---- |
Vinylidene chloride (1, 1-Dichloroethylene) |
75-35-4 | 1 ppm | 3 ppm | ---- | ---- |
VM & P Naphtha | 8032-32-4 | 300 ppm | 400 ppm | ---- | ---- |
Warfarin | 81-81-2 | 0.1 mg/m3 | 0.3 mg/m3 | ---- | ---- |
Welding fumes (total particulate) |
---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Wood dust | ---- | ---- | ---- | ---- | ---- |
Nonallergenic; (All woods except allergenics) |
---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Allergenics (e.g. cedar, mahogany and teak) |
---- | 2.5 mg/m3 | 5 mg/m3 | ---- | ---- |
Xylenes (ortho, meta, and para isomers) (Dimethylbenzene) |
1330-20-7 | 100 ppm | 150 ppm | ---- | ---- |
m-Xylene alpha, alpha-diamine | 1477-55-0 | ---- | ---- | 0.1 mg/m3 | X |
Xylidine (Dimethylaminobenzene) |
1300-73-8 | 2 ppm | 4 ppm | ---- | X |
Yttrium | 7440-65-5 | 1 mg/m3 | 3 mg/m3 | ---- | ---- |
Zinc chloride fume | 7646-85-7 | 1 mg/m3 | 2 mg/m3 | ---- | ---- |
Zinc chromate (as (( (see WAC 296-62-08003) |
Varies with compound | (( |
---- | 0.1 mg/m3 | ---- |
Zinc oxide | 1314-13-2 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m | ---- | ---- |
Zinc oxide fume | 1314-13-2 | 5 mg/g3 | 10 mg/m3 | ---- | ---- |
Zinc stearate | 557-05-1 | ---- | ---- | ---- | ---- |
Total particulate | ---- | 10 mg/m3 | 20 mg/m3 | ---- | ---- |
Respirable fraction | ---- | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
Zirconium compounds (as Zr) | 7440-67-2 | 5 mg/m3 | 10 mg/m3 | ---- | ---- |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 04-18-079, § 296-841-20025, filed 8/31/04, effective 11/1/04.]
Breathing zone
The space around and in front of an employee's nose and mouth, forming a hemisphere with a six to nine inch radius.
Ceiling limit
((An exposure limit, measured over the shortest time
period feasible, that must not be exceeded during any part of
the employee's workday.)) See Permissible exposure limits
(PELs).
Dust
Solid particles suspended in air. Dusts are generated by handling, drilling, crushing, grinding, rapid impact, detonation, or decrepitation of organic or inorganic materials such as rock, ore, metal, coal, wood, grain, etc.
Exposed or exposure
The contact an employee has with a toxic substance, harmful physical agent or oxygen deficient condition, whether or not protection is provided by respirators or other personal protective equipment (PPE). Exposure can occur through various routes of entry, such as inhalation, ingestion, skin contact, or skin absorption.
Fume
Solid particles suspended in air, generated by condensation from the gaseous state, generally after volatilization from molten metals, etc.
Gas
A normally formless fluid which can be changed to the liquid or solid state by the effect of increased pressure or decreased temperature or both.
General exhaust ventilation
The general movement of air out of an area or permit-required confined space by mechanical or natural means.
Immediately dangerous to life or health (IDLH)
An atmospheric condition that would:
Cause an immediate threat to life
or
Cause permanent or delayed adverse health effects
or
Interfere with an employee's ability to escape
Mist
Liquid droplets suspended in air, generated by condensation from the gaseous to the liquid state or by breaking up a liquid into a dispersed state, such as by splashing, foaming, spraying or atomizing.
Nuisance dust (or inert dust)
Dusts that, when inhaled, have little adverse effect on the lungs and do not produce significant organic disease or toxic effect when exposures are kept under reasonable control.
The biological reaction to these dusts in lung tissue has the following characteristics:
The architecture of the air spaces remains intact
Scar tissue (collagen) isn't formed to a significant extent
The tissue reaction is potentially reversible
Oxygen deficient
An atmosphere with an oxygen content below 19.5% by volume.
Permissible exposure limits (PEL)
((Permissible exposure limits (PELs) are employee
exposures to toxic substances or harmful agents that must not
be exceeded. PELs are specified in applicable WISHA rules.))
The amount of an airborne chemical, toxic substance, or other
harmful agent that must not be exceeded during any part of the
workday.
An airborne chemical or toxic substance can have 3 PEL values:
TWA8. This is an 8-hour, time-weighted average limit.
Short-term exposure limit (STEL). This is typically a 15-minute, time-weighted average limit.
Ceiling limit (C). This is an instantaneous limit.
Short-term exposure limit (STEL)
((An exposure limit averaged over a short time period
(usually measured for fifteen minutes) that must not be
exceeded during any part of an employee's workday.)) See
Permissible exposure limits (PELs).
Temper
To condition air for a specific work environment by changing its temperature or moisture content.
Time weighted average (TWA8)
((An exposure limit averaged over eight hours that must
not be exceeded during an employee's workday.)) See
Permissible exposure limits (PELs).
Toxic substance
Any chemical substance or biological agent, such as bacteria, virus, and fungus, which is any of the following:
Listed in the latest edition of the National Institute for Occupational Safety and Health (NIOSH) Registry of Toxic Effects of Chemical Substances (RTECS)
Shows positive evidence of an acute or chronic health hazard in testing conducted by, or known to, the employer.
The subject of a material safety data sheet kept by or known to the employer showing the material may pose a hazard to human health.
Vapor
The gaseous form of a substance that is normally in the solid or liquid state.
Ventilation
Providing, circulating or exhausting air into or out of an area or space.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 04-18-079, § 296-841-300, filed 8/31/04, effective 11/1/04; 03-20-115, § 296-841-300, filed 10/1/03, effective 1/1/04.]
OTS-8908.1
REPEALER
The following sections of the Washington Administrative Code are repealed:
WAC 296-62-100 | Oxygen deficient atmospheres. |
WAC 296-62-110 | Ventilation. |
WAC 296-62-11001 | Definition. |
WAC 296-62-11003 | Ventilation guide. |
WAC 296-62-11005 | Adequate system. |
WAC 296-62-11007 | Exhaust. |
WAC 296-62-11009 | Make-up air quantity. |
WAC 296-62-11011 | Design and operation. |
WAC 296-62-11013 | Compatibility of systems. |
WAC 296-62-11017 | Grinding, polishing, and buffing operations. |
OTS-9397.1
AMENDATORY SECTION(Amending WSR 05-20-055, filed 10/3/05,
effective 12/1/05)
WAC 296-78-71015
Tanks and chemicals.
(1) All open vats
and tanks into which workers may fall shall be guarded with
standard railings or screen guards in all cases where such
guarding is possible with regard to practical operation.
(2) Foundations of elevated tanks shall be accessible for inspections. When the tank platform is more than five feet above the ground a stairway or ladder shall be permanently attached.
(3) Every open tank over five feet in height shall be equipped with fixed standard ladders both inside and out, extending from the bottom to the rim of the tank arranged to be accessible to each other, so far as local conditions permit.
(4) The use of chemicals for treating of lumber for prevention of sap stain or mold or as preservatives, shall conform to the requirements of chapter 296-835 WAC, Dipping and coating operations (dip tanks).
(a) Storage, handling, and use of chemicals. Threshold
limits. Employees shall not be exposed to airborne
concentration of toxic dusts, vapors, mists or gases that
exceed the threshold limit values set forth in chapter 296-62 WAC, Part H, and chapter 296-841 WAC, ((Respiratory hazard))
Airborne contaminants.
(b) Protective equipment. The use of chemicals shall be controlled so as to protect employees from harmful exposure to toxic materials. Where necessary, employees shall be provided with and required to wear such protective equipment as will afford adequate protection against harmful exposure as required by WAC 296-800-160, and chapter 296-842 WAC, Respirators.
(5)(a) Means shall be provided and used to collect any excess of chemicals used in treating lumber so as to protect workers from accidental contact with harmful concentrations of toxic chemicals or fumes.
(b) Dip tanks containing flammable or combustible liquids shall be constructed, maintained and used in accordance with chapter 296-835 WAC, Dipping and coating operations (dip tanks).
(c) An evacuation plan shall be developed and implemented for all employees working in the vicinity of dip tanks using flammable and/or combustible liquids. A copy of the plan shall be available at the establishment for inspection at all times. Every employee shall be made aware of the evacuation plan and know what to do in the event of an emergency and be evacuated in accordance with the plan. The plan shall be reviewed with employees at least quarterly and documented.
(d) When automatic foam, automatic carbon dioxide or automatic dry chemical extinguishing systems are used, an alarm device shall be activated to alert employees in the dip tank area before and during the activation of the system. The following combinations of extinguishment systems when used in conjunction with the evacuation plan as stated above will be acceptable in lieu of bottom drains:
(i) A dip tank cover with an automatic foam extinguishing system under the cover, or an automatic carbon dioxide system, or an automatic dry chemical extinguishing system, or an automatic water spray extinguishing system;
(ii) An automatic dry chemical extinguishing system with an automatic carbon dioxide system or a second automatic dry chemical extinguishing system or an automatic foam extinguishing system;
(iii) An automatic carbon dioxide system with a second automatic carbon dioxide system or an automatic foam extinguishing system.
(e) The automatic water spray extinguishing systems, automatic foam extinguishing systems, and dip tank covers shall conform with the requirements of chapter 296-835 WAC, Dipping and coating operations (dip tanks). The automatic carbon dioxide systems and dry chemical extinguishing system shall conform with the requirements of WAC 296-24-615 and 296-24-620.
(6) Where workers are engaged in the treating of lumber with chemicals or are required to handle lumber or other materials so treated, the workers shall be provided with, at no cost to the worker, and required to use such protective equipment as will provide complete protection against contact with toxic chemicals or fumes therefrom.
(7) Sanitation requirements. The requirements of WAC 296-800-220 and 296-800-230 (safety and health core rules), shall govern sanitation practices.
(8) The sides of steam vats and soaking pits unless otherwise guarded shall extend forty-two inches above the floor level. The floor adjacent thereto shall be of nonslip construction.
(9) Large steam vats or soaking pits, divided into sections, shall be provided with substantial walkways between each section, each walkway to be provided with standard railings which may be removable if necessary.
(10) Covers shall be removed only from that portion of the steaming vats on which workers are working and a portable railing shall be placed at this point to protect the operators.
(11) Workers shall not ride or step on logs in steam vats.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-20-055, § 296-78-71015, filed 10/3/05, effective 12/1/05; 05-03-093, § 296-78-71015, filed 1/18/05, effective 3/1/05. Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. 02-15-102, § 296-78-71015, filed 7/17/02, effective 10/1/02; 01-11-038, § 296-78-71015, filed 5/9/01, effective 9/1/01. Statutory Authority: Chapter 49.17 RCW. 96-17-056, § 296-78-71015, filed 8/20/96, effective 10/15/96; 94-20-057 (Order 94-16), § 296-78-71015, filed 9/30/94, effective 11/20/94. Statutory Authority: RCW 49.17.040, 49.17.050 and 49.17.240. 81-18-029 (Order 81-21), § 296-78-71015, filed 8/27/81.]
OTS-9398.1
AMENDATORY SECTION(Amending WSR 05-03-093, filed 1/18/05,
effective 3/1/05)
WAC 296-155-20301
Definitions.
Confined space means a
space that:
(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and
(2) Has limited or restricted means for entry or exit (for example, tanks, vessels, silos, storage bins, hoppers, vaults, and pits are spaces that may have limited means of entry); and
(3) Is not designed for continuous employee occupancy.
"Corrosives" means substances which in contact with living tissue cause destruction of the tissue by chemical action.
"Hazardous atmosphere" means an atmosphere that may expose employees to the risk of death, incapacitation, impairment of ability to self-rescue (that is, escape unaided from a permit space), injury, or acute illness from one or more of the following causes:
(1) Flammable gas, vapor, or mist in excess of ten percent of its lower flammable limit (LFL);
(2) Airborne combustible dust at a concentration that meets or exceeds its LFL;
Note: | This concentration may be approximated as a condition in which the dust obscures vision at a distance of five feet (1.52m) or less. |
(4) Atmospheric concentration of any substance for which
a dose or a permissible exposure limit is published in chapter 296-62 WAC, general occupational health standards, or chapter 296-841 WAC, ((identifying and controlling respiratory
hazards)) Airborne contaminants, and which could result in
employee exposure in excess of its dose or permissible
exposure limit;
Note: | An atmospheric concentration of any substance that is not capable of causing death, incapacitation, impairment of ability to self-rescue, injury, or acute illness due to its health effects is not covered by this provision. |
Note: | For air contaminants for which WISHA has not determined a dose or permissible exposure limit, other sources of information, such as material safety data sheets that comply with the Chemical Hazard Communication Standard, WAC 296-800-170, published information, and internal documents can provide guidance in establishing acceptable atmospheric conditions. |
"Oxygen deficient atmospheres" means atmospheres at sea level having less than 19.5% oxygen by volume or having a partial pressure of 148 millimeters of mercury or less. This may deviate when working at higher altitudes and should be determined for an individual location. Factors such as acclimatization, physical condition of persons involved, etc., must be considered for such circumstances and conditions. (See chapter 296-62 WAC, Part M, permit-required confined spaces.)
"Toxicants" means substances which have the inherent capacity to produce personal injury or illness to persons by absorption through any body surface.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-03-093, § 296-155-20301, filed 1/18/05, effective 3/1/05. Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. 01-11-038, § 296-155-20301, filed 5/9/01, effective 9/1/01. Statutory Authority: RCW 49.17.040, [49.17].050 and [49.17].060. 95-17-036, § 296-155-20301, filed 8/9/95, effective 9/25/95. Statutory Authority: Chapter 49.17 RCW. 95-04-007, § 296-155-20301, filed 1/18/95, effective 3/1/95; 91-24-017 (Order 91-07), § 296-155-20301, filed 11/22/91, effective 12/24/91. Statutory Authority: RCW 49.17.040 and 49.17.050. 86-03-074 (Order 86-14), § 296-155-20301, filed 1/21/86.]
OTS-9399.1
AMENDATORY SECTION(Amending WSR 05-19-086, filed 9/20/05,
effective 12/1/05)
WAC 296-304-01009
Precautions for hot work.
(1) General
requirements.
(a) Designated areas. The employer may designate areas for hot work in sites such as vessels, vessel sections, fabricating shops, and subassembly areas that are free of fire hazards.
(b) Nondesignated areas.
(i) Before authorizing hot work in a nondesignated area, the employer must visually inspect the area where hot work is to be performed, including adjacent spaces, to ensure the area is free of fire hazards, unless a marine chemist's certificate or shipyard competent person's log is used for authorization.
(ii) The employer shall authorize employees to perform hot work only in areas that are free of fire hazards, or that have been controlled by physical isolation, fire watches, or other positive means.
Note: | The requirements of (b) of this subsection apply to all hot work operations in shipyard employment except those covered by WAC 296-304-02007. |
(a) Maintaining fire hazard-free conditions. The
employer must keep all hot work areas free of new hazards that
may cause or contribute to the spread of fire. Unexpected
energizing and energy release are covered by WAC 296-304-120.
Exposure to toxic and hazardous substances is covered in
chapter 296-841 WAC, ((Respiratory hazards)) Airborne
contaminants; chapter 296-802 WAC, Employee medical and
exposure records; and WAC 296-800-170, Employer chemical
hazard communication -- Introduction.
(b) Fuel gas and oxygen supply lines and torches. The employer must make sure that:
(i) No unattended fuel gas and oxygen hose lines or torches are in confined spaces;
(ii) No unattended charged fuel gas and oxygen hose lines or torches are in enclosed spaces for more than fifteen minutes;
(iii) All fuel gas and oxygen hose lines are disconnected at the supply manifold at the end of each shift; and
(iv) All disconnected fuel gas and oxygen hose lines are rolled back to the supply manifold or to open air to disconnect the torch; or extended fuel gas and oxygen hose lines are not reconnected at the supply manifold unless the lines are given a positive means of identification when they were first connected and the lines are tested using a drop test or other positive means to ensure the integrity of fuel gas and oxygen burning system.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-19-086, § 296-304-01009, filed 9/20/05, effective 12/1/05.]
OTS-9400.1
AMENDATORY SECTION(Amending WSR 04-14-028, filed 6/29/04,
effective 1/1/05)
WAC 296-806-47502
Guard drum sanders.
You must:
Make sure drum sanders have one of the following to enclose that part of the drum not used to work on the material:
Guard.
Exhaust hood.
Reference: | Exhaust hoods are required on sanders when dust levels exceed exposure limits. (( |
Exemption: | When a table is used for the application of material to be finished, you do not need to enclose the portion of the drum above the table that is necessary to do the work. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 04-14-028, § 296-806-47502, filed 6/29/04, effective 1/1/05.]
OTS-9401.1
AMENDATORY SECTION(Amending WSR 04-03-081, filed 1/20/04,
effective 5/1/04)
WAC 296-809-800
Definitions.
Acceptable entry conditions:
The conditions that must exist in a permit-required confined space to allow safe entry and work.
Attendant:
An individual stationed outside one or more permit-required confined spaces to monitor the entrants.
Blanking or blinding:
The absolute closure of a pipe, line, or duct by fastening a solid plate (such as a spectacle blind or a skillet blind) that completely covers the bore. It is capable of withstanding the maximum pressure of the pipe, line, or duct with no leakage beyond the plate.
Confined space:
A space that is all of the following:
Large enough and arranged so an employee could fully enter the space and work.
Has limited or restricted entry or exit. Examples of spaces with limited or restricted entry are tanks, vessels, silos, storage bins, hoppers, vaults, excavations, and pits.
Not primarily designed for human occupancy.
Double block and bleed:
The closure of a line, duct, or pipe by closing and locking or tagging two in-line valves and by opening and locking or tagging a drain or vent valve in the line between the two closed valves.
Emergency:
Any occurrence (including any failure of hazard control or monitoring equipment) or event internal or external to the permit-required confined space that could endanger authorized entrants.
Engulfment:
The surrounding capture of a person by a liquid or finely divided (flowable) solid substance that can be inhaled to cause death by filling or plugging the respiratory system or that can exert enough force on the body to cause death by strangulation, constriction, or crushing.
Enter (entry):
The action by which a person passes through an opening
into a permit-required confined space and includes work
activities in that space. Entry is considered to have
occurred as soon as any part of the entrant's body breaks the
plane of an opening into the space.
Note: | If the opening is large enough for the worker to fully enter the space, a permit is required even for partial
body entry. Permits are not required for partial body entry where the opening is not large enough for full
entry, although other rules such as chapter 296-803 WAC, lockout-tagout, (( |
An employee who is authorized by the employer to enter a permit-required confined space.
Entry permit (permit):
The written or printed document that is provided by you to allow and control entry into a permit-required confined space and that contains the information required in WAC 296-809-500, Permit entry procedures.
Entry supervisor:
The person (such as the employer, crew leader, or crew chief) responsible for:
Determining if acceptable entry conditions are present at a permit-required confined space where entry is planned;
Authorizing entry and overseeing entry operations; and
Terminating entry as required.
Hazardous atmosphere:
An atmosphere that may expose employees to the risk of death, incapacitation, impairment of ability to self-rescue (that is, escape unaided from a permit-required confined space), injury, or acute illness caused by one or more of the following:
Flammable gas, vapor, or mist in excess of ten percent of its lower flammable limit (LFL).
Airborne combustible dust at a concentration that meets or exceeds its LFL.
Note: | This concentration may be approximated as a condition in which the dust obscures vision at a distance of five feet (1.52 m) or less. |
Atmospheric concentration of any substance which may
exceed a permissible exposure limit. For additional
information about atmospheric concentration, see chapter 296-62 WAC, Parts F, G, and I, General occupational health
standards and chapter 296-841 WAC, ((Respiratory hazards))
Airborne contaminants.
Note: | An airborne concentration of a substance that is not capable of causing death, incapacitation, impairment of ability to self-rescue, injury, or acute illness due to its health effects is not covered by this definition. |
Note: | You can find guidance on establishing acceptable atmospheric conditions for air contaminants, which have no WISHA-determined doses or permissible exposure limits using other sources of information, such as: |
Material safety data sheets required by WAC 296-800-170, Employer chemical hazard communication. | |
Published information. | |
Internal documents. |
A written authorization to perform operations, for example, riveting, welding, cutting, burning, and heating, that can provide a source of ignition.
Immediately dangerous to life or health (IDLH):
Any of the following conditions:
An immediate or delayed threat to life.
Anything that would cause irreversible adverse health effects.
Anything that would interfere with an individual's ability to escape unaided from a permit-required confined space.
Note: | Some materials - hydrogen fluoride gas and cadmium vapor, for example - may produce immediate transient effects that, even if severe, may pass without medical attention, but are followed by sudden, possibly fatal collapse twelve to seventy-two hours after exposure. The victim "feels normal" after recovery from transient effects until collapse. Such materials in hazardous quantities are considered to be "immediately" dangerous to life or health (IDLH). |
The displacement of the atmosphere in a permit-required
confined space by a noncombustible gas (such as nitrogen) to
such an extent that the resulting atmosphere is
noncombustible.
Note: | This procedure produces an IDLH oxygen-deficient atmosphere. |
The process by which a permit-required confined space is removed from service and completely protected against the release of energy and material into the space by such means as: Blanking or blinding; misaligning or removing sections of lines, pipes, or ducts; a double block and bleed system; lockout or tagout of all sources of energy; or blocking or disconnecting all mechanical linkages.
Line breaking:
The intentional opening of a pipe, line, or duct that is or has been carrying flammable, corrosive, or toxic material, an inert gas, or any fluid at a volume, pressure, or temperature capable of causing injury.
Nonpermit confined space:
A confined space that does NOT contain actual hazards or potential hazards capable of causing death or serious physical harm.
Oxygen deficient atmosphere:
An atmosphere containing less than 19.5 percent oxygen by volume.
Oxygen enriched atmosphere:
An atmosphere containing more than 23.5 percent oxygen by volume.
Permit-required confined space or permit space:
A confined space that has one or more of the following characteristics capable of causing death or serious physical harm:
Contains or has a potential to contain a hazardous atmosphere.
Contains a material with the potential for engulfing someone who enters.
Has an internal configuration that could allow someone entering to be trapped or asphyxiated by inwardly converging walls or by a floor, which slopes downward and tapers to a smaller cross section.
Contains any physical hazard. This includes any recognized health or safety hazards including engulfment in solid or liquid material, electrical shock, or moving parts.
Contains any other recognized serious safety or health hazard that could either:
Impair the ability to self-rescue; or
Result in a situation that presents an immediate danger to life or health.
Permit-required confined space program:
An overall program for:
Controlling and appropriately protecting employees from permit-required confined space hazards; and
Regulating employee entry into permit-required confined spaces.
Prohibited condition:
Any condition in a permit-required confined space that is not allowed by the permit during the authorized entry period.
Rescue service:
The personnel designated to rescue employees from permit-required confined spaces.
Retrieval system:
The equipment used for nonentry rescue of persons from permit-required confined spaces, such as a retrieval line, full-body harness or wristlets, and a lifting device or anchor.
Testing:
The process of identifying and evaluating the hazards that entrants may be exposed to in a permit-required confined space. Testing includes specifying the tests that are to be performed in the permit-required confined space.
Note: | Testing allows employers to devise and implement adequate controls to protect entrants during entry, and to determine if acceptable entry conditions are present. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 04-03-081, § 296-809-800, filed 1/20/04, effective 5/1/04.]
OTS-9402.1
AMENDATORY SECTION(Amending WSR 05-03-093, filed 1/18/05,
effective 3/1/05)
WAC 296-824-800
Definitions.
The following definitions
are specific to this chapter:
Annually
Any twelve-month cycle.
Buddy system
A system of organizing employees (who enter or stand by danger areas) into work groups, so each employee can be observed by at least one other member of the group. The purpose of this system is to provide rapid assistance to employees in an emergency.
Clean-up operation(s)
An operation where hazardous substances are removed, contained, incinerated, neutralized, stabilized, cleared up or, in any other manner, processed or handled with the goal of making the site safer for people or the environment.
Danger area
Areas where conditions pose a serious danger to employees, such as areas where:
Immediately dangerous to life or health (IDLH) conditions could exist
OR
High levels of exposure to toxic substances could exist
OR
There is a potential for exceeding the lower explosive limit (LEL), also known as the lower flammability limit (LFL), of a substance.
Decontamination
Removing hazardous substances from employees and their equipment so potential adverse health effects will not occur.
Emergency response
An organized response to an anticipated release of a hazardous substance that is, or could become an uncontrolled release.
Emergency response plan
A written plan that requires coordination between emergency response participants, and contains procedures, criteria, and other information that will be applied to emergency response operations. Each employer's plan should be compatible with local and state plans.
Engineering controls
Methods of controlling employee exposures by modifying the source or reducing the quantity of contaminants.
Hazardous materials team (HAZMAT team)
A group of employees who are expected to perform
responses to releases, or possible releases, of hazardous
substances for the purpose of control and stabilization. As a
result of their duties, HAZMAT team members may have close
contact with hazardous substances.
Note: | A HAZMAT team may be a separate component of a fire brigade or fire department. |
Any of the following substances that could adversely affect an exposed employee's health or safety:
Substances defined under section 101(14) of the Comprehensive Environmental Response, Compensation and Liability Act of 1980 (CERCLA) or "Superfund" Act (visit: http://www.epa.gov)
Biological or other disease-causing agents released that could reasonably be expected to cause death, disease, behavioral abnormalities, cancer, genetic mutation, physiological malfunctions (including malfunctions in reproduction) or physical deformations in a person or their offspring when the person:
Is directly exposed to the agent in the environment
Directly ingests, inhales, or assimilates the agent from the environment
Indirectly ingests the agent through a food chain
Substances listed by the United States Department of Transportation as hazardous materials under Title 49 (Transportation) in the Code of Federal Regulations (CFR), Part 172, section 101 and appendices (visit: http://www.nara.gov and search for "List of CFR subjects")
Hazardous wastes as defined in this chapter.
Hazardous waste
A substance designated by chapter 173-303 WAC, Dangerous
waste regulations, department of ecology, as a dangerous waste
or an extremely hazardous waste and any waste fitting the
definition of "health hazard" in this chapter.
Note: | For department of ecology regulations, visit: http://www.ecy.wa.gov |
A chemical, a mixture of chemicals, or a pathogen for which there is statistically significant evidence, based on at least one study conducted according to established scientific principles, that acute or chronic health effects may occur in exposed employees.
The term "health hazard" includes stress due to temperature extremes and chemicals that are:
Carcinogens
Toxic or highly toxic agents
Reproductive toxins, irritants, corrosives, sensitizers, hepatotoxins, nephrotoxins, or neurotoxins
Agents acting on the hematopoietic system agents that damage lungs, skin, eyes, or mucous membranes. (Detailed definitions of these chemical terms can be found in the Safety and health core rules, WAC 296-800-170, chemical hazard communication.)
Incident command system (ICS)
An organized approach to control and manage operations at an emergency response incident.
Incidental release
A release that can be safely controlled at the time of the release and does not have the potential to become an uncontrolled release.
Note:
A tanker truck is receiving a load of hazardous liquid when a leak occurs. The driver knows the only hazard from the liquid is minor skin irritation. The employer has trained the driver on procedures and provided equipment to use for a release of this quantity. The driver puts on skin protection and stops the leak. A spill kit is used to contain, absorb, and pick up the spilled material for disposal.
Immediately dangerous to life or health (IDLH)
Any atmospheric condition that would:
Cause an immediate threat to life
OR
Cause permanent or delayed adverse health effects
OR
Interfere with an employee's ability to escape
Limited action
Action necessary to:
Secure an operation during emergency responses,
OR
Prevent an incident from increasing in severity.
Examples include shutting down processes and closing emergency valves.
Lines of authority
A preestablished ranking of individuals, qualified to assume a commanding role during an emergency response, noted in an emergency response plan and implemented during a response. This is most important when responders from multiple employers could participate in an emergency response.
Lower explosive limit (LEL)
See lower flammable limit (LFL).
Lower Flammable limit (LFL)
The lowest concentration of a material that will propagate a flame. The LFL is usually expressed as a percent (by volume) of the material in air (or other oxidant).
Must
Must means mandatory.
Permissible exposure limit (PEL)
Means the established time-weighted-average (TWA)
concentration or ceiling concentration of a contaminant that
must not be exceeded. The exposure, inhalation, or dermal
permissible limit specified in chapter 296-841 WAC,
((identifying and controlling respiratory hazards)) Airborne
contaminants.
Personal protective equipment (PPE)
Protective items designed to be worn by the user to protect them against airborne, skin contact and other hazards. This includes items such as respiratory protection, protective suits, gloves, eye protection, etc.
Postemergency response
The stage of the emergency response where the immediate threat from the release has been stabilized or eliminated, and cleanup of the site has started.
Published exposure level
Exposure limits published in "National Institute for Occupational Safety and Health (NIOSH) Recommendations for Occupational Safety and Health" (DHHS publication #92-100, 1992).
If an exposure limit is not published by NIOSH, then
"published exposure level" means the exposure limits published
by the American Conference of Governmental Industrial
Hygienists (ACGIH) in "TLVs and BEIs-Threshold Limit Values
for Chemical Substances and Physical Agents" (1999 edition).
Note: | Additional exposure levels published by recognized organizations such as the American Industrial Hygiene Association are not required to be observed by this rule; however, they may be a useful resource when a hazardous substance is not covered by NIOSH and ACGIH publications. |
A spill, leak, or other type of hazardous substance discharge.
Uncontrolled release
A release where significant safety and health risks could be created. Releases of hazardous substances that are either incidental or could not create a safety or health hazard (i.e., fire, explosion or chemical exposure) are not considered to be uncontrolled releases.
Large-quantity releases
Small releases that could be highly toxic
Potentially contaminated individuals arriving at hospitals
Airborne exposures that could exceed a WISHA permissible exposure limit or a published exposure limit and employees are not adequately trained or equipped to control the release.
A forklift driver knocks over a container of a solvent-based liquid, releasing the contents onto the warehouse floor. The driver has been trained to recognize the vapor is flammable and moderately toxic when inhaled. The driver has not been trained or provided appropriate equipment to address this type of spill. In this situation, it is not safe for the driver to attempt a response. The driver needs to notify someone of the release so an emergency response can be initiated.
Workplace
A fixed facility
OR
A temporary location (such as a traffic corridor)
OR
Locations where employees respond to emergencies.
You
The employer. For a complete definition of "employer" see Safety and health core rules, chapter 296-800 WAC.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-03-093, § 296-824-800, filed 1/18/05, effective 3/1/05; 02-20-034, § 296-824-800, filed 9/24/02, effective 10/1/02.]
OTS-9403.1
AMENDATORY SECTION(Amending WSR 06-02-060, filed 1/3/06,
effective 4/1/06)
WAC 296-828-100
Scope.
This chapter applies to the
laboratory use of hazardous chemicals. To determine if this
chapter applies to your workplace, use Table 1.
When your laboratory operation is covered by this chapter, and you use any of the substances in Table 2, the following applies:
The exposure limits and any requirement protecting employees from skin and eye contact in the rules listed in Table 2 will still apply.
Where the action level (or where no action level exists, the permissible exposure limit) is exceeded for a substance listed in Table 2, the exposure evaluation and medical surveillance requirements in the substance rule will still apply.
You are not required to meet other requirements of the substance rule.
To get the permissible exposure limits (PELs) for
hazardous chemicals used in your laboratory, see chapter 296-841 WAC, ((Respiratory hazards)) Airborne contaminants.
Acrylonitrile |
Arsenic (inorganic) |
Asbestos |
Benzene |
Butadiene |
Cadmium |
Coke ovens |
Cotton dust |
1, 2-Dibromo-3-chloropropane |
Ethylene oxide |
Formaldehyde |
Lead |
Methylene chloride |
Methylenedianiline |
Vinyl chloride |
Ionizing radiation |
4-Nitrobiphenyl |
Alpha-Naphthylamine |
4,4' Methylene bis (2 - chloroaniline) |
Methyl chloromethyl ether |
3,3'-Dichlorobenzidine (and its salts) |
Bis-Chloromethyl ether |
Beta-Naphthylamine benzidine |
4-Aminodiphenyl |
Ethyleneimine |
Beta-Propiolactone |
2-Acetylaminofluorene |
4-Dimethylaminoazobenzene |
N-Nitrosodimethylamine |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 06-02-060, § 296-828-100, filed 1/3/06, effective 4/1/06.]
You must:
Develop and carry out a written chemical hygiene plan
(CHP) that will protect your employees from hazardous
substances in the laboratory and keep exposure levels below
those listed in ((Respiratory hazards,)) chapter 296-841 WAC,
Airborne contaminants.
Make sure the written plan is readily available to employees and their representatives.
Include the following elements in your written CHP:
The names or job titles of the chemical hygiene officer, other personnel responsible for implementing the CHP, or when appropriate, the members of a chemical hygiene committee.
Standard operating procedures that provide employee protection when working with hazardous substances.
Criteria for how you will select and use control measures to reduce employee exposures to hazardous chemicals, especially chemicals known to be extremely hazardous.
Additional employee protection for select carcinogens, reproductive toxins, and chemicals with high degree of acute toxicity. The following will be considered, when appropriate:
▪ The establishment of exposure control areas.
▪ Containment devices, such as fume hoods or glove boxes.
▪ The safe removal of contaminated waste.
▪ Procedures for decontamination.
Specific measures to make sure fume hoods and other protective equipment provide proper and adequate performance and are properly functioning.
The circumstances when specific laboratory operation, activity, or procedure requires prior approval from the employer or their designated representative before implementation.
A description of how you are going to train and inform your employees about laboratory use of hazardous chemicals.
A description of your provisions for medical consultations and medical examinations.
Review and evaluate the effectiveness of your written CHP at least annually and update as necessary.
Reference: | This publication can provide you with additional information to help you with your written chemical hygiene plan: |
National Research Council, Prudent Practices for Disposal of Chemicals from Laboratories, National Academy Press, Washington, DC, 1995. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 06-02-060, § 296-828-20005, filed 1/3/06, effective 4/1/06.]
OTS-9404.1
AMENDATORY SECTION(Amending WSR 05-03-093, filed 1/18/05,
effective 3/1/05)
WAC 296-839-30005
Develop or obtain material safety data
sheets (MSDSs).
You must:
Develop or obtain a complete and accurate material safety data sheet (MSDS) for each hazardous chemical or mixture according to ALL of the following:
ALL information in Table 8 must be completed. If there is no relevant information for a required item, this must be noted. Blank spaces are not permitted.
Note: | No specific format is required for MSDSs; however, an example format (OSHA form 174) can be found online at: http://www.osha.gov |
One MSDS can be developed for a group of complex mixtures (for example, jet fuels or crude oil) IF the health and physical hazards of the mixtures are similar (the amounts of chemicals in the mixture may vary). |
Note: | You may report results of scientifically valid studies that tend to refute findings of hazards. |
Note: | You may develop copies of MSDSs in other languages. |
Revise an MSDS when you become aware of new and significant information regarding the hazards of a chemical, or how to protect against the hazards
Within three months after you first become aware of the information
OR
Before the chemical is reintroduced into the workplace
if the chemical is no longer being used, produced or imported.
Table 8 Information Required on MSDSs |
The chemical's identity as it appears on the label |
The date the MSDS was prepared or updated |
A contact for additional information about the hazardous
chemical and appropriate emergency procedures Include all of the
following: Name Address Telephone number of the responsible party preparing or distributing the MSDS |
The chemical's hazardous ingredients1 as determined by your
hazard evaluation For a single substance chemical, include the chemical and common name(s) of the substance For mixtures tested as a whole ▪ Include the common name(s) of the mixture AND ▪ List the chemical and common name(s) of ingredients that contribute to the known hazards For mixtures NOT tested as a whole, list the chemical and common name(s) of hazardous ingredients ▪ That make up 1% or more of the mixture, by weight or volume, including carcinogens (if 0.1% concentration or more, by weight or volume) If ingredients are less than the above concentrations but may present a health risk to employees (for example, allergic reaction or exposure could exceed the permissible exposure limits, or PEL) they must be listed here |
Exposure limits for airborne concentrations. Include ALL of the
following, when they exist: WISHA or OSHA PELs2 ▪ The 8-hour time weighted average (TWA) ▪ The short-term exposure limit (STEL), if available ▪ Ceiling values, if available Threshold limit values (TLVs) including 8-hour TWAs, STELs, and ceiling values Other exposure limits used or recommended by the employer preparing the MSDS |
Physical and chemical characteristics For example, boiling point, vapor pressure, and odor |
Fire, explosion data, and related information For example, flashpoint, flammable and explosion limits, extinguishing media, and unusual fire or explosion hazards |
Physical hazards of the chemical including reactivity
information For example, incompatibilities, decomposition products, by-products, and conditions to avoid |
Health hazard information including ALL of the following: Primary routes of exposure ▪ For example, inhalation, ingestion, and skin absorption or other contact3 Health effects (or hazards) associated with: ▪ Short-term exposure4 AND ▪ Long-term exposure4 Whether the chemical is listed or described as a carcinogen or potential carcinogen in the latest editions of each of the following: |
▪ The National Toxicology Program (NTP) Annual
Report on Carcinogens OR ▪ The International Agency for Research on Cancer (IARC) Monographs as a potential carcinogen OR ▪ WISHA or OSHA rules Signs and symptoms of exposure5 Medical conditions generally recognized as being aggravated by exposure |
Emergency and first-aid procedures |
Generally applicable precautions for safe handling and use
known to the employer preparing the MSDS For example, appropriate procedures for clean-up of spills and leaks, waste disposal method, precautions during handling and storing |
Generally applicable and appropriate control measures known to
the employer preparing the MSDS, including ALL of the following: Engineering controls (for example, general or local exhaust ventilation) Work practices Personal protective equipment (PPE) Personal hygiene practices Protective measures during repair and maintenance of contaminated equipment |
1The identities of some chemicals may be protected as trade secret information (see chapter 296-62 WAC, Part B-1, Trade secrets). | |
2 WISHA PEL categories are defined, and values are provided, in chapter 296-841 WAC, (( |
|
3 A "skin notation" listed with either an ACGIH TLV or WISHA/OSHA PEL indicates that skin absorption is a primary route of exposure. | |
4Examples of: | |
Short-term health effects (or hazards) include eye irritation, skin damage caused by contact with corrosives, narcosis, sensitization, and lethal dose. | |
Long-term health effects (or hazards) include cancer, liver degeneration, and silicosis. | |
5Signs and symptoms of exposure to hazardous substances include those that: | |
Can be measured such as decreased pulmonary function | |
AND | |
Are subjective such as feeling short of breath. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-03-093, § 296-839-30005, filed 1/18/05, effective 3/1/05; 03-01-096, § 296-839-30005, filed 12/17/02, effective 6/1/03.]
OTS-9406.1
AMENDATORY SECTION(Amending WSR 05-13-152, filed 6/21/05,
effective 8/1/05)
WAC 296-849-11030
Exposure evaluations.
IMPORTANT:
When you conduct an exposure evaluation in a workplace where an employee uses a respirator, the protection provided by the respirator is not considered.
Following this section will fulfill the requirements to
identify and evaluate respiratory hazards found in ((another
chapter, Respiratory hazards,)) chapter 296-841 WAC, Airborne
contaminants.
You must:
Conduct an employee exposure evaluation to accurately determine airborne concentrations of benzene by completing Steps 1 through 7 of the exposure evaluation process, each time any of the following apply:
No evaluation has been conducted.
▪ You have up to thirty days to complete an evaluation once benzene is introduced into your workplace.
Changes have occurred in any of the following areas that may result in new or increased exposures:
▪ Production.
▪ Processes.
▪ Exposure controls such as ventilation systems or work practices.
▪ Personnel.
You have any reason to suspect new or increased exposure may occur.
Spills, leaks, or other releases have been cleaned up.
Note: | As part of your exposure evaluation after cleanup, you will make sure exposure monitoring results have returned to prerelease levels. |
IMPORTANT:
If you are evaluating employee exposures during cleaning and repair of barges and tankers that contained benzene:
Collect samples that effectively measure benzene concentrations that employees may be exposed to;
AND
Skip to Step 7.
Following the exposure evaluation process is not necessary when you have documentation conclusively demonstrating benzene exposures for a particular operation and material cannot exceed the action level (AL) during any conditions reasonably anticipated.
Documentation can be based on data or qualitative information, such as information about:
▪ The material.
▪ How the material is handled.
▪ The work conditions.
Retain this documentation for as long as you rely on it.
Step 1: Identify all employees who have potential airborne exposure to benzene in your workplace.
Step 2: Identify operations where fifteen-minute exposures could exceed benzene's short-term exposure limit (STEL) of 5 parts per million (ppm).
Include operations where it is reasonable to expect high, fifteen-minute exposures, such as operations where:
Tanks are opened, filled, unloaded, or gauged.
Containers or process equipment are opened.
Benzene is used as a solvent for cleaning.
Note: | You may use monitoring devices such as colorimetric indicator tubes or real-time monitors to screen for activities where employee exposure monitoring results could be high. |
Step 4: Select employees from those identified in Step 1 who will have their eight-hour exposures monitored.
Make sure the exposures of the employees selected represent eight-hour exposures for all employees identified at Step 1, including each job classification, work area, and shift.
Note: | A written description of the procedure used for obtaining representative employee exposure monitoring results needs to be kept as part of your exposure records required by this chapter in Exposure records, WAC 296-849-11090. This description can be created while completing Steps 3 through 6 of this exposure evaluation process. |
Select and use a method that is accurate to ±25%, with a confidence level of 95%.
Note: | Here are examples of methods that meet this accuracy requirement: |
OSHA Method 12 for air samples, found by going to http://www.osha.gov/dts/sltc/methods/toc.html. | |
NIOSH Method 1500, found by going to http://www.cdc.gov/niosh/homepage.html and link to the NIOSH Manual of Analytical Methods. |
Collect fifteen-minute samples from employees selected at Step 3.
Sample at least one shift representative of the eight-hour exposure for each employee selected at Step 4.
Make sure samples are collected from each selected employee's breathing zone.
Collecting area samples is permitted after emergency releases.
Note: | You may use any sampling method that meets the accuracy specified in Step 5. Examples of these methods include: |
Real-time monitors that provide immediate exposure monitoring results. | |
Equipment that collects samples that are sent to a laboratory for analysis. | |
The following are examples of methods of monitoring representative of eight-hour exposures: | |
Collect one or more continuous samples, for example, a single eight-hour sample or four two-hour samples. | |
Take a minimum of five brief samples, such as fifteen-minute samples, during the work shift and at times selected randomly. | |
For work shifts longer than eight hours, monitor the continuous eight-hour portion of the shift expected to have the highest average exposure concentration. |
Go to the scope of this chapter, WAC 296-849-100, and
compare employee exposure monitoring results to the values
found in Step 2a and follow Step 2b to determine if additional
sections of this chapter apply.
Note: | You may contact your local WISHA consultant for help: |
Interpreting data or other information. | |
Obtaining eight-hour or fifteen-minute employee exposure monitoring results. | |
To contact a WISHA consultant: | |
Go to another chapter, the Safety and health core rules, chapter 296-800 WAC, and find the resources section, and under "other resources," find service location for labor and industries. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-13-152, § 296-849-11030, filed 6/21/05, effective 8/1/05; 05-01-172, § 296-849-11030, filed 12/21/04, effective 3/1/05.]
Exemption: | This section does not apply to the cleaning and repair of barges and tankers that contained benzene. |
Establish and implement a written exposure control plan
for exposure control areas that include a schedule for
developing and implementing feasible exposure controls to
reduce benzene exposure to, or below, the PELs.
(( |
Note: | Respirators and other personal protective equipment (PPE) help protect employees from exposures, but are not substitutes for feasible exposure controls. |
Review and update your exposure control plan as needed, based on the most recent exposure evaluation results.
Provide a copy of your exposure control plan to affected employees and their designated representatives when they ask to review or copy it.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-172, § 296-849-13005, filed 12/21/04, effective 3/1/05.]
IMPORTANT:
Respirators and other personal protective equipment (PPE) do not substitute for feasible exposure controls.
You must:
Use feasible exposure controls to reduce exposures, as specified in Table 6.
(( |
Table 6
Exposure Control Requirements
If: | Then you must use feasible controls to: |
You have operations where employees clean and repair barges or tankers which have contained benzene | Keep all employee exposure concentrations below 10 parts per million (ppm). |
You can document that benzene is used for less than thirty days a year in the workplace | Reduce eight-hour employee exposure monitoring results to a time-weighted average of 10 ppm or less. |
Note: | |
If employee exposure monitoring results are between 1 and 10 ppm, you are permitted to use respirators or a combination of respirators and feasible controls to protect employees. | |
Employees are exposed to benzene above a PEL for at least thirty days a year | Reduce eight-hour employee exposure concentrations to the TWA8 of 1 ppm or less; |
AND | |
Reduce fifteen-minute employee exposure concentrations to the STEL of 5 ppm or less. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-172, § 296-849-13020, filed 12/21/04, effective 3/1/05.]