1.04 × | SACC |
(3.7117 × SACC 0.6384) |
where "SACC" is seasonally adjusted cooling capacity in Btu/h.
(13)(a) Residential ventilating fans must meet the qualification criteria of the environmental protection agency energy star program product specification for residential ventilating fans, version 3.2, consistent with the timeline specified in RCW
19.260.050(3).
(b) Residential ventilating fans must meet the qualification criteria of the environmental protection agency energy star program product specification for residential ventilating fans, version 4.1, consistent with the timeline specified in RCW
19.260.050(3).
(14) Spray sprinkler bodies that are not specifically excluded from the scope of the environmental protection agency water sense program product specification for spray sprinkler bodies, version 1.0, must include an integral pressure regulator and must meet the water efficiency and performance criteria and other requirements of that specification.
(15) The following products that are within the scope and definition of the applicable regulation must meet the requirements in the California Code of Regulations, Title 20, section 1605.3 in effect as of January 1, 2018, as measured in accordance with the test methods prescribed in the California Code of Regulations, Title 20, section 1604 in effect as of January 1, 2018:
(a) Showerheads;
(b) Tub spout diverters;
(c) Showerhead tub spout diverter combinations;
(d) Lavatory faucets and replacement aerators;
(e) Kitchen faucets and replacement aerators;
(f) Public lavatory faucets and replacement aerators;
(g) Urinals; and
(h) Water closets.
(16) Water coolers included in the scope of the environmental protection agency energy star program product specification for water coolers, version 2.0, must have an on mode with no water draw energy consumption less than or equal to the following values as measured in accordance with the test requirements of that program:
(a) 0.16 kilowatt-hours per day for cold-only units and cook and cold units;
(b) 0.87 kilowatt-hours per day for storage type hot and cold units; and
(c) 0.18 kilowatt-hours per day for on demand hot and cold units.
(17) General service lamps must meet or exceed a lamp efficacy of 45 lumens per watt, when tested in accordance with the applicable federal test procedures for general service lamps prescribed in 10 C.F.R. Sec. 430.23 in effect as of January 3, 2017.
(18) Air purifiers other than industrial air purifiers must meet the qualification criteria of the environmental protection agency energy star program product specification for room air cleaners, version 2.0.
(19) Commercial ovens included in the scope of the energy star program requirements product specification for commercial ovens, version 2.2, must meet the qualification criteria of that specification.
(20) Electric vehicle supply equipment included in the scope of the energy star program requirements product specification for electric vehicle supply equipment, version 1.0, other than charging cords with NEMA 5-15P or NEMA 5-20P attachment plugs, must meet the qualification criteria of that specification.