AAMA | American Architectural Manufacturers Association | |
| 1827 Walden Office Square | | |
| Suite 550 | | |
| Schaumburg, IL 60173-4268 | | |
Standard reference number | Title | | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A C440-17 | North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights | . . . . . . . . | R402.4.2 |
ACCA | Air Conditioning Contractors of America | |
| 2800 Shirlington Road, Suite 300 | | |
| Arlington, VA 22206 | | |
Standard reference number | Title | | Referenced in code section number |
Manual J-16 | Residential Load Calculation Eighth Edition | . . . . . . . . | R403.7 |
Manual S-14 | Residential Equipment | . . . . . . . . | R403.7 |
ANSI | American National Standards Institute 25 West 43rd Street, 4th Floor New York, NY 10036 | |
Standard reference number | Title | | Referenced in code section number |
Z21.50-2016/CSA 2.22-2016 | Vented Decorative Gas Appliances | . . . . . . . . | R403.7.1 |
Z21.88-2017/CSA 2.33-2017 | Vented Gas Fireplace Heaters | . . . . . . . . | R403.7.1 |
Z21.40.2-1996 | Gas-fired, Work Activated Air-Conditioning and Heat Pump Appliances (Internal Combustion) | . . . . . . . . | Table R406.3 |
Z21.40.4-1996 | Performance Testing and Rating of Gas-Fired, Air-Conditioning and Heat Pump Appliances | . . . . . . . . | Table R406.3 |
APSP | The Association of Pool and Spa Professionals | |
| 2111 Eisenhower Avenue, Suite 500 | | |
| Alexandria, VA 22206 | | |
Standard reference number | Title | | Referenced in code section number |
ANSI/APSP/ICC 14-2019 | American National Standard for Portable Electric Spa Energy Efficiency | . . . . . . . . | R403.11 |
ANSI/APSP/ICC 15a-2011 | American National Standard for Residential Swimming Pool and Spa Energy Efficiency—Includes Addenda A approved January 9, 2013 | . . . . . . . . | R403.12 |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. | |
| 1791 Tullie Circle, N.E. | | |
| Atlanta, GA 30329-2305 | | |
Standard reference number | Title | | Referenced in code section number |
ASHRAE-2021 | ASHRAE Handbook of Fundamentals | . . . . . . . . | R402.1.5, Table R405.5.2(1) |
ASHRAE 193-2010 (RA 2014) | Method of Test for Determining the Airtightness of HVAC Equipment | . . . . . . . . | R403.3.4.1 |
ASTM | ASTM International | | |
| 100 Barr Harbor Drive | | |
| West Conshohocken, PA 19428-2859 | | |
Standard reference number | Title | | Referenced in code section number |
C1363-11 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus | . . . . . . . . | R303.1.4.1 |
E283-2004 (2012) | Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen | . . . . . . . . | R402.4.3 |
E779-2010 (2018) | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization | . . . . . . . . | R402.4.1.2 |
E1554/E1554M-E2013 | Standard Test Method for Determining Air Leakage of Air Distribution Systems by Fan Pressurization | . . . . . . . . | R403.3.5 |
E1827-2011 (2017) | Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door | . . . . . . . . | R402.4.1.2 |
E2178-2013 | Standard Test Method for Air Permeance of Building Materials | . . . . . . . . | R303.1.5 |
E3158-2018 | Standard Test Method for Measuring the Air Leakage Rate of a Large or Multizone Building | . . . . . . . . | R402.4.1.2 |
CSA | Canadian Standards Association | |
| 5060 Spectrum Way | | |
| Mississauga, Ontario, Canada L4W 5N6 | | |
Standard reference number | Title | | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440-17 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | . . . . . . . . | R402.4.2 |
CSA 55.1-2015 | Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Systems | . . . . . . . . | R403.5.4, Table R406.2 |
CSA 55.2-2015 | Drain Water Heat Recovery Units | . . . . . . . . | R403.5.4 |
CSA P.4.1-15 | Testing Method for Measuring Annual Fireplace Efficiency | . . . . . . . . | R403.7.1 |
DASMA | Door and Access Systems Manufacturers Association | | |
| 1300 Sumner Avenue | | |
| Cleveland, OH 44115-2851 | | |
105-2017 | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors | . . . . . . . . | R303.1.3 |
HVI | Home Ventilating Institute | | |
| 1000 North Rand Road, Suite 214 | | |
| Wauconda, IL 60084 | | |
916-18 | Airflow Test Procedure | . . . . . . . . | R303.1.3 |
ICC | International Code Council, Inc. | |
| 500 New Jersey Avenue, N.W. | | |
| 6th Floor | | |
| Washington, DC 20001 | | |
Standard reference number | Title | | Referenced in code section number |
ANSI/APSP/ICC 14-2019 | American National Standard for Portable Electric Spa Energy Efficiency | . . . . . . . . | R403.11 |
ANSI/APSP/ICC 15a-2011 | American National Standard for Residential Swimming Pool and Spa Energy Efficiency—Includes Addenda A approved January 9, 2013 | . . . . . . . . | R403.12 |
ANSI/RESNET/ICC 380-2019 | Standard for Testing Airtightness of building, Dwelling Unit and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems | . . . . . . . . | R402.4.1.2 |
IBC-21 | International Building Code | . . . . . . . . | R201.3, R303.2, R402.11, R4501.4 |
ICC 400-17 | Standard on the Design and Construction of Log Structures | . . . . . . . . | Table R402.1.1 |
ICC 500-2020 | ICC/NSSA Standard for the Design and Construction of Storm Shelters | . . . . . . . . | R402.5 |
IFC-21 | International Fire Code | . . . . . . . . | R201.3, R501.4 |
IFGC-21 | International Fuel Gas Code | . . . . . . . . | R201.3, R501.4 |
IFGC-21 | International Mechanical Code | . . . . . . . . | R201.3, R403.3.2, R403.6, R501.4 |
IPMC-21 | International Property Maintenance Code | . . . . . . . . | R501.4 |
IRC-21 | International Residential Code | . . . . . . . . | R104.2.1, R201.3, R303.2, R401.2, R403.2.2, R403.5, R406.1, R406.2, Table R406.2 |
IEEE | The Institute of Electrical and Electronic Engineers, Inc. | |
| 3 Park Avenue | | |
| New York, NY 10016-5997 | | |
Standard reference number | Title | | Referenced in code section number |
515.1-2012 | IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications | . . . . . . . . | R403.5.1.2 |
ISO | International Organization for Standardization | |
| 1, rue de Varembe, Case postale 56, CH-1211 | | |
| Geneva, Switzerland | | |
Standard reference number | Title | | Referenced in code section number |
ISO/IEC 17024-2012 | Conformity Assessment: General requirements for bodies operating certification of persons | . . . . . . . . | R402.4.1.2 |
NEEA | Northwest Energy Efficiency Alliance | |
| 421 S.W. 6th Ave., Suite 600 | | |
| Portland, OR 97204 | | |
Standard reference number | Title | | Referenced in code section number |
NEEA-2011 | Northern Climate Specification for Heat Pump Water Heaters, Vers. 4.0 | . . . . . . . . | Table R406.3 |
NEEA-2019 | Advanced Water Heating Specifications for Gas-Fueled Residential Storage Water Heaters, Version 1.0. | . . . . . . . . | Table R406.3 |
NEEP | Northeast Energy Efficiency Partnership, Inc. | | |
| 24 School Street, 2nd Floor | | |
| Boston, MA 02108-4314 | | |
Standard reference number | Title | | Referenced in code section number |
ccASHP Version 3.1 | Cold Climate Air Source Heat Pump (ccASHP) Product List and Specifications:
https://neep.org/heating-electrification/ccashp-specification-product-list
| . . . . . . . . | Table R406.3 |
NEMA | National Electrical Manufacturers Association | | |
| 1300 17th Street N No. 900 | | |
| Arlington, VA 22209 | | |
Standard reference number | Title | | Referenced in code section number |
OS4-2016 | Requirements for Air-Sealed Boxes for Electrical and Communications Applications | . . . . . . . . | R402.4.4 |
NFPA | National Fire Protection Association | | |
| 1 Batterymarch Park | | |
| Quincy, MA 02169-7417 | | |
Standard reference number | Title | | Referenced in code section number |
70-20 | National Electrical Code | . . . . . . . . | R501.4 |
NFRC | National Fenestration Rating Council, Inc. | |
| 6305 Ivy Lane, Suite 140 | | |
| Greenbelt, MD 20770 | | |
Standard reference number | Title | | Referenced in code section number |
100-2020 | Procedure for Determining Fenestration Products U-factors | . . . . . . . . | R303.1.3 |
200-2020 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence | . . . . . . . . | R303.1.3 |
400-2020 | Procedure for Determining Fenestration Product Air Leakage | . . . . . . . . | R402.4.2 |
UL | Underwriters Laboratory | |
| 333 Pfingsten Road | | |
| Northbrook, IL 60062 | | |
Standard reference number | Title | | Referenced in code section number |
UL 127-11 | Factory Built Fireplace | . . . . . . . . | R402.3.6 |
UL 515-11 | Electric Resistance Heat Tracing for Commercial and Industrial Applications | . . . . . . . . | R403.5.1.2 |
UL 907-94 | Fireplace Accessories (with revisions through April 2010) | . . . . . . . . | R402.3.6 |
US-FTC | United States-Federal Trade Commission | |
| 600 Pennsylvania Avenue N.W. | | |
| Washington, DC 20580 | | |
Standard reference number | Title | | Referenced in code section number |
C.F.R. Title 16 (2015) | R-value Rule | . . . . . . . . | Rule R303.1.4 |
WDMA | Window and Door Manufacturers Association | |
| 1400 East Touhy Avenue, Suite 470 | | |
| Des Plaines, IL 60018 | | |
Standard reference number | Title | | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440-17 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | . . . . . . . . | R402.4.2 |
WSU | Washington State University Energy Extension Program | |
| 905 Plum Street S.E., Bldg 3 | | |
| P.O. Box 43165 | | |
| Olympia, WA 98506-3166 | | |
Standard reference number | Title | | Referenced in code section number |
WSU RS 33 | Duct Testing Standard for New and Existing Construction Publication No. WSUEEP15-016 | . . . . . . . . | R403.3.3 |
[Statutory Authority: RCW
19.27A.020,
19.27A.045,
19.27A.160, and chapter
19.27A RCW. WSR 24-03-084, § 51-11R-51000, filed 1/16/24, effective 3/15/24; WSR 23-02-060, 23-12-102, and 23-20-022, § 51-11R-51000, filed 1/3/23, 6/7/23, and 9/25/23, effective 3/15/24. Statutory Authority: RCW
19.27A.020,
19.27A.045,
19.27A.160 and chapter
19.27 RCW. WSR 20-01-047, § 51-11R-51000, filed 12/9/19, effective 7/1/20. Statutory Authority: RCW
19.27A.020,
19.27A.045,
19.27A.160, and
19.27.074. WSR 16-02-127, § 51-11R-51000, filed 1/6/16, effective 7/1/16.]