1 The parameter must be measured at the end of the unit process or alternative monitoring location as set in a reclaimed water permit. |
Coagulation/Filtration | ||||
Parameter1 | Class A Reclaimed Water | Class B Reclaimed Water | ||
Turbidity2 | Monthly Average | Sample Maximum | Monthly Average | Sample Maximum |
2 NTU | 5 NTU | Not Applicable | Not Applicable | |
Membrane Filtration | ||||
Class A Reclaimed Water | Class B Reclaimed Water | |||
Turbidity2 | Monthly Average | Sample Maximum | Monthly Average | Sample Maximum |
0.2 NTU | 0.5 NTU | Not Applicable | Not Applicable | |
Disinfection | ||||
Class A Reclaimed Water | Class B Reclaimed Water | |||
Total Coliform | 7-Day Median | Sample Maximum | 7-Day Median | Sample Maximum |
2.2 MPN/100 mL or CFU/100 mL | 23 MPN/mL or CFU/mL | 23 MPN/mL or CFU/mL | 240 MPN/mL or CFU/mL | |
Virus Removal | See disinfection process standards in WAC 173-219-340 | Not Applicable | Not Applicable | |
Denitrification3 | ||||
Class A Reclaimed Water | Class B Reclaimed Water | |||
Total Nitrogen | Monthly Average | Weekly Average | Monthly Average | Weekly Average |
10 mg/L | 15 mg/L | Not Applicable | Not Applicable |
1 The parameter must be measured at the end of the unit process or alternative monitoring location as set in a reclaimed water permit. | |
2 Sample maximum for turbidity is the highest value for the day that lasts longer than five minutes. | |
3 Not applicable for beneficial uses 1-13 listed on Table 3: Use-Based Requirements. |