Note: | Wood will meet this requirement. |
(c) You must ensure that footwalks are continuous and permanently secured.
(d) Footwalks should have a clear passageway at least 18 inches wide except opposite the bridge motor, where they should be not less than 15 inches. The inner edge must extend at least to the line of the outside edge of the lower cover plate or flange of the girder.
(4) Ladders and stairways.
(a) You must provide gantry cranes with ladders or stairways extending from the ground to the footwalk or cab platform.
(b) You must equip stairways with rigid and substantial metal handrails. You must ensure that walking surfaces are of an antislip type.
(c) You must permanently and securely fasten ladders in place and ensure that they are constructed in compliance with chapter
296-876 WAC, Ladders, portable and fixed.
[Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050, and
49.17.060. WSR 15-24-100, § 296-24-23507, filed 12/1/15, effective 1/5/16; WSR 06-16-020, § 296-24-23507, filed 7/24/06, effective 12/1/06. Statutory Authority: RCW
49.17.010, [49.17].040, and [49.17].050. WSR 01-11-038, § 296-24-23507, filed 5/9/01, effective 9/1/01. Statutory Authority: Chapter
49.17 RCW. WSR 94-15-096 (Order 94-07), § 296-24-23507, filed 7/20/94, effective 9/20/94; Order 73-5, § 296-24-23507, filed 5/9/73 and Order 73-4, § 296-24-23507, filed 5/7/73.]