Note: | These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be operated from the outside. |
(4) Ventilation.
(a) A two-inch air space must be left around ceilings and the perimeter of floors, except at doorways;
(b) Foundation ventilators must be at least four inches by six inches;
(c) Vents in the foundation, roof, or gables must be screened and offset.
(5) Exposed metal.
(a) Sparking metal cannot be exposed below the top of walls in the storage facilities;
(b) All nails must be blind nailed, countersunk, or nonsparking.
Note: | The following are nonmandatory construction alternatives for magazine exteriors: |
| 1. All steel and wood dimensions shown are actual thickness; |
| 2. The manufacturer's represented thickness may be used to meet the concrete block and brick dimensions. |
3/16
(c) 3/16-inch steel lined with an interior of 4-inch hardwood.
(d) 3/16-inch steel lined with:
(i) An interior of 7 inches of softwood; or
(ii) 6 3/4 inches of plywood.
(e) 3/16-inch steel lined with:
(i) An intermediate layer of 3-inch hardwood; and
(ii) An interior lining of 3/4-inch plywood.
1/8
(f) 1/8-inch steel lined with an interior of 5-inch hardwood.
(g) 1/8-inch steel lined with an interior of 9-inch softwood.
(h) 1/8-inch steel lined with:
(i) An intermediate layer of 4-inch hardwood; and
(ii) An interior lining of 3/4-inch plywood.
(i) Reserved.
(j) 1/8-inch steel lined with:
(i) A first intermediate layer of 3/4-inch plywood;
(ii) A second intermediate layer of 3 5/8 inches well-tamped dry sand; or
(iii) Sand/cement mixture.
(6) An interior lining of 3/4-inch plywood.
(a) 5/8-inch steel lined with an interior of any type of nonsparking material.
(b) 1/2-inch steel lined with an interior of at least 3/8-inch plywood.
(c) 3/8-inch steel lined with an interior of 2-inch hardwood.
(d) 3/8-inch steel lined with an interior of:
(i) 3 inches softwood; or
(ii) 2 1/4 inches of plywood.
(e) 1/4-inch steel lined with:
(i) An interior of 5 inches of softwood; or
(ii) 5 1/4 inches of plywood.
(f) Any type of structurally sound fire resistant material lined with:
(i) An intermediate layer of 4-inch solid concrete block; or
(ii) 4-inch solid brick or concrete; and
(iii) An interior lining of 1/2-inch plywood placed securely against the masonry lining.
(g) Standard 8-inch concrete block with voids filled with well tamped sand/cement mixture.
(h) Standard 8-inch solid brick.
(i) Reserved.
(j) Any type of structurally sound fire resistant material lined with an intermediate 6-inch space filled with:
(i) Well tamped dry sand; or
(ii) Well tamped sand/cement mixture.
(k) Any type of fire resistant material lined with:
(i) A first intermediate layer of 3/4-inch plywood;
(ii) A second intermediate layer of 3 5/8-inch well tamped dry sand; or
(iii) Sand/cement mixture;
(iv) A third intermediate layer of 3/4-inch plywood;
(v) A fourth intermediate layer of 2-inch hardwood; or
(vi) 14 gauge steel and an interior lining of 3/4-inch plywood;
(vii) 8-inch thick solid concrete.
[Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050, and
49.17.060. WSR 17-16-132, § 296-52-70025, filed 8/1/17, effective 9/1/17; WSR 05-08-110, § 296-52-70025, filed 4/5/05, effective 6/1/05. Statutory Authority: RCW