EXCEPTION: | Cast iron in tension shall not be used for supporting members for idler and deflecting sheaves where hung beneath beams. |
(4) The factor of safety for beams and support shall be no less than:
(a) 5 For steel; and
(b) 6 For timber and reinforced concrete.
[Statutory Authority: Chapter
70.87 RCW. WSR 18-18-070, § 296-96-24121, filed 8/31/18, effective 10/1/18.]