The minimum rated load shall be not less than the following:
(1) For net platform areas up to and including 12 ft2, the rated load shall be not less than 40 lbs./ft2 or 350 lbs. whichever is greater.
(2) For net platform areas greater than 12 ft2, the rated load shall be based upon 62.5 lbs./ft2.
[Statutory Authority: Chapter
70.87 RCW. WSR 18-18-070, § 296-96-24124, filed 8/31/18, effective 10/1/18.]