(2) The employer must make sure the moisture content of the air supplied meets the following:
(a) Air supplied to respirators from cylinders must NOT exceed a dew point of -50°F (or -45.6°C) at 1 atmospheric pressure.
(b) Compressor supplied air must NOT exceed a dew point of 10°F (or 5.56°C) BELOW the use temperature at 1 atmospheric pressure.
(3) The employer must make sure cylinders obtained from a supplier of breathing air must have a certificate of analysis that verifies each cylinder's contents meet Grade D and dew point standards.
(4) The employer must make sure compressed and liquid oxygen meet the United States Pharmacopoeia requirements for medical or breathing oxygen.