Note: | • Use required cleaning and disinfecting procedures in WAC 296-307-62015, or the manufacturer's procedures that: |
| – Result in a clean and sanitary respirator |
| – Do not damage the respirator |
| – Do not harm the user |
| • Automated cleaning and disinfecting are permitted |
| • Cleaning and disinfecting may be done by a central facility as long as you make sure respirators provided are clean, sanitary, and function properly. |
You must:
• Make sure respirators are assembled properly after cleaning or disinfecting.
Use Table 8 to determine how often to clean and disinfect respirators.
Table 8
Required Frequencies for Cleaning and Disinfecting Respirators
If, the respirator will be . . . | Then, clean and disinfect the respirator . . . |
• Used exclusively by one employee | • As often as needed to: |
| | – Keep it clean and functional |
| | and |
| | – To prevent health hazards such as skin irritation |
• Shared for nonemergency use | • Before it is worn by another employee |
or |
• Used for fit-testing or training | |
• Shared for emergency use | • After each use so the respirator is immediately ready for use at all times |