Reference: | See the American National Standards Institute - Compressed Gas Association Commodity Specification for Air (G-7.1.1989) for more information. Contact your local library to access a copy. |
You must:
• Make sure the moisture content of the air supplied meets the following:
– Air supplied to respirators from cylinders must not exceed a dew point of -50°F (or -45.6°C) at 1 atmospheric pressure.
– Compressor supplied air must not exceed a dew point of 10°F (or 5.56°C) below the use temperature at 1 atmospheric pressure.
• Cylinders obtained from a supplier of breathing air must have a certificate of analysis that verifies each cylinder's contents meet Grade D and dew point standards.
• Compressed and liquid oxygen must meet the United States Pharmacopoeia requirements for medical or breathing oxygen.