Criteria | Adult Trout > 6 in. (150 mm) | Adult Pink, Chum Salmon | Adult Chinook, Coho, Sockeye, Steelhead |
1. Velocity, Maximum (fps) |
Culvert Length (ft) |
a. 10 - 60 | 4.0 | 5.0 | 6.0 |
b. 60 - 100 | 4.0 | 4.0 | 5.0 |
c. 100 - 200 | 3.0 | 3.0 | 4.0 |
d. > 200 | 2.0 | 2.0 | 3.0 |
2. Flow Depth Minimum (ft) | 0.8 | 0.8 | 1.0 |
3. Hydraulic Drop, Maximum (ft) | 0.8 | 0.8 | 1.0 |
(E) Appropriate statistical or hydraulic methods must be applied for the determination of flows in (b)(ii)(A) and (B) of this subsection. These design flow criteria may be modified for specific proposals as necessary to address unusual fish passage requirements, where other approved methods of empirical analysis are provided, or where the fish passage provisions of other special facilities are approved by the department.
(F) Culvert design shall include consideration of flood capacity for current conditions and future changes likely to be encountered within the stream channel, and debris and bedload passage.
(c) Culverts shall be installed according to an approved design to maintain structural integrity to the 100-year flood level with consideration of the debris loading likely to be encountered. Exception may be granted if the applicant provides justification for a different level or a design that routes the flow past the culvert without jeopardizing the culvert or associated fill.
(d) Disturbance of the bed and banks shall be limited to that necessary to place the culvert and any required channel modification associated with it. Affected bed and bank areas outside the culvert and associated fill shall be revegetated with native or other approved woody species, or stabilized with other approved erosion control techniques, and maintained as necessary to ensure survival. See board manual section 5 for technical guidance.
(e) Fill associated with the culvert installation shall be protected from erosion to the 100-year flood level.
(f) Culverts shall be designed and installed to avoid inlet scouring and shall be designed in a manner to prevent erosion of stream banks downstream of the project.
(g) Where fish passage criteria are required, the culvert facility shall be maintained by the landowner(s), such that fish passage design criteria in Table 1 are not exceeded. If the structure becomes a hindrance to fish passage, the landowner shall be responsible for obtaining an approved forest practices application and providing prompt repair.
(h) The culvert shall be installed in the dry or in isolation from the stream flow by the installation of a bypass flume or culvert, or by pumping the stream flow around the work area. Exception may be granted if siltation or turbidity is reduced by installing the culvert in the flowing stream. The bypass reach shall be limited to the minimum distance necessary to complete the project. Fish stranded in the bypass reach shall be safely removed to the flowing stream.
(i) Wastewater from project activities and dewatering shall be routed to the forest floor in an upland area, or above the 100-year flood level if present, as necessary to allow removal of fine sediment and other contaminants prior to being discharged to any typed water or wetland.
(7) Alternative designs will be considered if they can be demonstrated to meet or exceed fish protection standards. Alternative designs may require additional review.
[Statutory Authority: RCW
76.09.040(3). WSR 13-21-032, § 222-24-041, filed 10/8/13, effective 12/30/13.]