1 | Low-eA (emissivity) shall be 0.24 to 0.16. |
Low-eB (emissivity) shall be 0.15 to 0.08. | |
Low-eC (emissivity) shall be 0.07 or less. | |
2 | Aluminum Thermal Break = An aluminum thermal break framed window shall incorporate the following minimum design characteristics: |
a) | The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft2/°F; |
b) | The thermal break material must produce a gap in the frame material of not less than 0.210 inches; and |
c) | All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in a) and b) above. |
3 | A minimum air space of 0.375 inches between panes of glass is required for double glazing. |
4 | A minimum air space of 0.25 inches between panes of glass is required for triple glazing. |
5 | Deemed to comply glazing shall not be used for performance compliance. |