PDFWAC 51-11C-610331

Section A103.3.1—Single stud wall.

A103.3.1 Single-stud wall. Tables A103.3.1(1) through A103.3.1(8): Assumes either 2 x 4 or 2 x 6 studs framed on 16 or 24 inch centers. Headers are solid for 2 x 4 walls and double 2x for 2 x 6 walls, with either dead-air or rigid-board insulation in the remaining space.
TABLE A103.3.1(1)
 
 
2 x 4 Single Wood Stud: R-11 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
ADV
STD
ADV
 
NOTE:
Nominal Batt R-value:
R-11 at 3.5 inch thickness
Installed Batt R-value:
R-11 in 3.5 inch cavity
0
0.088
0.084
0.094
0.090
 
1
0.080
0.077
0.085
0.082
 
2
0.074
0.071
0.078
0.075
 
3
0.069
0.066
0.072
0.070
 
4
0.064
0.062
0.067
0.065
 
5
0.060
0.058
0.063
0.061
 
6
0.056
0.055
0.059
0.057
 
7
0.053
0.052
0.055
0.054
 
8
0.051
0.049
0.052
0.051
 
9
0.048
0.047
0.050
0.049
 
10
0.046
0.045
0.047
0.046
 
11
0.044
0.043
0.045
0.044
 
12
0.042
0.041
0.043
0.042
 
 
 
 
TABLE A103.3.1(2)
 
 
2 x 4 Single Wood Stud: R-13 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
ADV
STD
ADV
 
NOTE:
Nominal Batt R-value:
R-13 at 3.63 inch thickness
Installed Batt R-value:
R-12.7 in 3.5 inch cavity
0
0.082
0.078
0.088
0.083
 
1
0.075
0.072
0.080
0.076
 
2
0.069
0.066
0.073
0.070
 
3
0.065
0.062
0.068
0.065
 
4
0.060
0.058
0.063
0.061
 
5
0.057
0.055
0.059
0.057
 
6
0.053
0.052
0.056
0.054
 
7
0.051
0.049
0.052
0.051
 
8
0.048
0.047
0.050
0.048
 
9
0.046
0.045
0.047
0.046
 
10
0.044
0.043
0.045
0.044
 
11
0.042
0.041
0.043
0.042
 
12
0.040
0.039
0.041
0.040
 
 
 
 
TABLE A103.3.1(3)
 
 
2 x 4 Single Wood Stud: R-15 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
ADV
STD
ADV
 
NOTE:
Nominal Batt R-value:
R-15 at 3.5 inch thickness
Installed Batt R-value:
R-15 in 3.5 inch cavity
0
0.076
0.071
0.081
0.075
 
1
0.069
0.065
0.073
0.069
 
2
0.064
0.061
0.068
0.069
 
3
0.060
0.057
0.063
0.059
 
4
0.056
0.053
0.059
0.056
 
5
0.053
0.051
0.055
0.052
 
6
0.050
0.048
0.052
0.050
 
7
0.047
0.046
0.049
0.047
 
8
0.045
0.044
0.047
0.045
 
9
0.043
0.042
0.044
0.043
 
10
0.041
0.040
0.042
0.041
 
11
0.039
0.038
0.041
0.039
 
12
0.038
0.037
0.039
0.038
 
 
 
 
TABLE A103.3.1(4)
 
 
2 x 6 Single Wood Stud: R-19 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
INT
ADV
STD
INT
ADV
 
NOTE:
Nominal Batt R-value:
R-19 at 6 inch thickness
Installed Batt R-value:
R-18 in 5.5 inch cavity
0
0.062
0.058
0.055
0.065
0.061
0.058
 
1
0.058
0.055
0.052
0.060
0.057
0.055
 
2
0.054
0.052
0.050
0.056
0.054
0.051
 
3
0.051
0.049
0.047
0.053
0.051
0.049
 
4
0.048
0.046
0.045
0.050
0.048
0.046
 
5
0.046
0.044
0.043
0.048
0.046
0.044
 
6
0.044
0.042
0.041
0.045
0.044
0.042
 
7
0.042
0.040
0.039
0.043
0.042
0.040
 
8
0.040
0.039
0.038
0.041
0.040
0.039
 
9
0.038
0.037
0.035
0.039
0.038
0.037
 
10
0.037
0.036
0.035
0.038
0.037
0.036
 
11
0.036
0.035
0.034
0.036
0.035
0.035
 
12
0.034
0.033
0.033
0.035
0.034
0.033
 
 
 
 
TABLE A103.3.1(5)
 
 
2 x 6 Single Wood Stud: R-21 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
INT
ADV
STD
INT
ADV
 
NOTE:
Nominal Batt R-value:
R-21 at 5.5 inch thickness
Installed Batt R-value:
R-21 in 5.5 inch cavity
0
0.057
0.054
0.051
0.060
0.056
0.053
 
1
0.054
0.051
0.048
0.056
0.053
0.050
 
2
0.050
0.048
0.045
0.052
0.050
0.047
 
3
0.048
0.045
0.043
0.049
0.047
0.045
 
4
0.045
0.043
0.041
0.047
0.045
0.043
 
 
5
0.043
0.041
0.040
0.044
0.042
0.041
 
 
6
0.041
0.039
0.038
0.042
0.041
0.039
 
 
7
0.039
0.038
0.036
0.040
0.039
0.037
 
 
8
0.038
0.036
0.035
0.039
0.037
0.036
 
 
9
0.036
0.035
0.034
0.037
0.036
0.035
 
 
10
0.035
0.034
0.033
0.036
0.035
0.033
 
 
11
0.033
0.033
0.032
0.034
0.033
0.032
 
 
12
0.032
0.031
0.031
0.033
0.032
0.031
 
 
 
 
TABLE A103.3.1(6)
 
 
2 x 6 Single Wood Stud: R-22 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
INT
ADV
STD
INT
ADV
 
NOTE:
Nominal Batt R-value:
R-22 at 6.75 inch thickness
Installed Batt R-value:
R-20 in 5.5 inch cavity
0
0.059
0.055
0.052
0.062
0.058
0.054
 
1
0.055
0.052
0.049
0.057
0.054
0.051
 
2
0.052
0.049
0.047
0.054
0.051
0.048
 
3
0.049
0.046
0.044
0.050
0.048
0.046
 
4
0.046
0.044
0.042
0.048
0.046
0.044
 
5
0.044
0.042
0.041
0.045
0.043
0.042
 
6
0.042
0.040
0.039
0.043
0.042
0.040
 
 
7
0.040
0.039
0.037
0.041
0.040
0.038
 
 
8
0.038
0.037
0.036
0.039
0.038
0.037
 
 
9
0.037
0.036
0.035
0.038
0.037
0.035
 
 
10
0.035
0.034
0.033
0.036
0.035
0.034
 
 
11
0.034
0.033
0.032
0.035
0.034
0.033
 
 
12
0.033
0.032
0.031
0.034
0.033
0.032
 
 
 
 
TABLE A103.3.1(7)
 
 
2 x 6 Single Wood Stud: Two R-11 Batts
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
INT
ADV
STD
INT
ADV
 
NOTE:
Nominal Batt R-value:
R-22 at 7 inch thickness
Installed Batt R-value:
R-18.9 in 5.5 inch cavity
0
0.060
0.057
0.054
0.063
0.059
0.056
 
1
0.056
0.053
0.051
0.059
0.056
0.053
 
2
0.053
0.050
0.048
0.055
0.052
0.050
 
3
0.050
0.048
0.046
0.052
0.049
0.047
 
4
0.047
0.045
0.044
0.049
0.047
0.045
 
 
5
0.045
0.043
0.042
0.046
0.045
0.043
 
 
6
0.043
0.041
0.040
0.044
0.043
0.041
 
 
7
0.041
0.040
0.038
0.042
0.041
0.039
 
 
8
0.039
0.038
0.037
0.040
0.039
0.038
 
 
9
0.038
0.037
0.036
0.039
0.038
0.036
 
 
10
0.036
0.035
0.034
0.037
0.036
0.035
 
 
11
0.035
0.034
0.033
0.036
0.035
0.034
 
 
12
0.034
0.033
0.032
0.034
0.034
0.033
 
 
 
 
TABLE A103.3.1(8)
 
 
2 x 8 Single Stud: R-25 Batt
 
 
 
Siding Material/Framing Type
 
 
 
Lapped Wood
T1-11
 
 
R-value of
FoamBoard
STD
INT
ADV
STD
INT
ADV
 
NOTE:
Nominal Batt R-value:
R-25 at 8 inch thickness
Installed Batt R-value:
R-23.6 in 7.25 inch cavity
0
0.051
0.047
0.045
0.053
0.049
0.046
 
1
0.048
0.045
0.043
0.049
0.046
0.044
 
2
0.045
0.043
0.041
0.047
0.044
0.042
 
3
0.043
0.041
0.039
0.044
0.042
0.040
 
4
0.041
0.039
0.037
0.042
0.040
0.038
 
 
5
0.039
0.037
0.036
0.040
0.038
0.037
 
 
6
0.037
0.036
0.035
0.038
0.037
0.036
 
 
7
0.036
0.035
0.033
0.037
0.035
0.034
 
 
8
0.035
0.033
0.032
0.035
0.034
0.033
 
 
9
0.033
0.032
0.031
0.034
0.033
0.032
 
 
10
0.032
0.031
0.030
0.033
0.032
0.031
 
 
11
0.031
0.030
0.029
0.032
0.031
0.030
 
 
12
0.030
0.029
0.028
0.031
0.030
0.029
 
 
 
 
[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-610331, filed 2/1/13, effective 7/1/13.]