Studs and plates | 0.19 |
Insulated cavity | 0.77 |
Headers | 0.04 |
A103.2.2 Intermediate. Studs framed on 16 inch centers with double top plate and single bottom plate. Corners use two studs or other means of fully insulating corners, and each opening is framed by two studs. Headers consist of double 2x material with R-10 insulation. Interior partition wall/exterior wall intersections are fully insulated in the exterior wall.
Intermediate framing weighting factors:
Studs and plates | 0.18 |
Insulated cavity | 0.78 |
Headers | 0.04 |
A103.2.3 Advanced. Studs framed on 24 inch centers with double top plate and single bottom plate. Corners use two studs or other means of fully insulating corners, and one stud is used to support each header. Headers consist of double 2x material with R-10 insulation. Interior partition wall/exterior wall intersections are fully insulated in the exterior wall.
Advanced framing weighting factors:
Studs and plates | 0.13 |
Insulated cavity | 0.83 |
Headers | 0.04 |