PDFWAC 51-11C-71038

Table B103(8)—Retail occupancy.

Table B103(8)
Retail Occupancya
 
Schedule for
Occupancy
Schedule forLightingb/Receptacle
 
Schedule for Service Hot Water
Schedule for
Elevator
Hour of Day (time)
Percent of
Maximum Load
Percent of
Maximum Load
Schedule for HVAC System
Percent of
Maximum Load
Percent of
Maximum Load
 
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
1
(12-1am)
0
0
0
5
5
5
Off
Off
Off
4
11
7
0
0
0
2
(1-2am)
0
0
0
5
5
5
Off
Off
Off
5
10
7
0
0
0
3
(2-3am)
0
0
0
5
5
5
Off
Off
Off
5
8
7
0
0
0
4
(3-4am)
0
0
0
5
5
5
Off
Off
Off
4
6
6
0
0
0
5
(4-5am)
0
0
0
5
5
5
Off
Off
Off
4
6
6
0
0
0
6
(5-6am)
0
0
0
5
5
5
Off
Off
Off
4
6
6
0
0
0
7
(6-7am)
0
0
0
5
5
5
On
On
Off
4
7
7
0
0
0
8
(7-8am)
10
10
0
20
10
5
On
On
Off
15
20
10
12
9
0
9
(8-9am)
20
20
0
50
30
10
On
On
On
23
24
12
22
21
0
10
(9-10am)
50
50
10
85/90
55/60
10
On
On
On
32
27
14
64
56
11
11
(10-11am)
50
60
20
85/90
85/90
40
On
On
On
41
42
29
74
66
13
12
(11-12pm)
70
80
20
85/90
85/90
40
On
On
On
57
54
31
68
68
35
13
(12-1pm)
70
80
40
85/90
85/90
55/60
On
On
On
62
59
36
68
68
37
14
(1-2pm)
70
80
40
85/90
85/90
55/60
On
On
On
61
60
36
71
69
37
15
(2-3pm)
70
80
40
85/90
85/90
55/60
On
On
On
50
49
34
72
70
39
16
(3-4pm)
80
80
40
85/90
85/90
55/60
On
On
On
45
48
35
72
69
41
17
(4-5pm)
70
80
40
85/90
85/90
55/60
On
On
On
46
47
37
73
66
38
18
(5-6pm)
50
60
20
85/90
85/90
40
On
On
Off
47
46
34
68
58
34
19
(6-7pm)
50
20
10
55/60
50
20
On
On
Off
42
44
25
68
47
3
20
(7-8pm)
30
20
0
55/60
30
5
On
On
Off
34
36
27
58
43
0
21
(8-9pm)
30
20
0
50
30
5
On
On
Off
33
29
21
54
43
0
22
(9-10pm)
0
10
0
20
10
5
Off
On
Off
23
22
16
0
8
0
23
(10-11pm)
0
0
0
5
5
5
Off
Off
Off
13
16
10
0
0
0
24
(11-12am)
0
0
0
5
5
5
Off
Off
Off
8
13
6
0
0
0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Total/Day
750
750
280
1060/
1115
940/
985
500/
525
1500
1600
900
662
690
459
844
761
288
Total/Week
 
46.30
hours
 
67.40/
70.85
hours
 
100
hours
 
44.59
hours
 
52.69
hours
Total/Year
 
2414
hours
 
3505/ 3694
hours
 
5214
hours
 
2325
hours
 
2747
hours
Wk
= Weekday
a
Schedules for occupancy, lighting, receptacle, HVAC system and service hot water are from ASHRAE Standard 90.1-1989 and addendums, except that 5 percent emergency lighting has been added for all off hours. Elevator schedules, except for restaurants, are from the U.S. Department of Energy Standard Evaluation Techniques except changed to 0 percent when occupancy is 0 percent. These values may be used only if actual schedules are not known.
b
Lighting profiles are modified to reflect the requirement for occupancy sensors in Section C405.2.
[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-71038, filed 2/1/13, effective 7/1/13.]