(Effective July 1, 2023)

PDFWAC 51-50-1003

Section 1003General means of egress.

1003.7 Elevators, escalators and moving walks. Elevators, escalators and moving walks shall not be used as a component of a required means of egress from any other part of the building.
EXCEPTIONS:
1. Elevators used as an accessible means of egress in accordance with Section 1009.4.
 
2. Escalators used as a means of egress for fixed transit and passenger rail system accordance with Section 3116.
[Statutory Authority: RCW 19.27.031 and 19.27.074. WSR 22-13-094, § 51-50-1003, filed 6/14/22, effective 7/1/23.]