EXCEPTIONS: | In monolithic and multiple-layer sloped glazing systems, the following applies: |
| 1. Fully tempered glass installed without protective screens where glazed between intervening floors at a slope of 30 degrees (0.52 rad) or less from the vertical plane shall have the highest point of the glass 10 feet (3048 mm) or less above the walking surface. |
| 2. Screens are not required below any glazing material, including annealed glass, where the walking surface below the glazing material is permanently protected from the risk of falling glass or the area below the glazing material is not a walking surface. |
| 3. Any glazing material, including annealed glass, is permitted to be installed without screens in the sloped glazing systems of commercial or detached noncombustible greenhouses used exclusively for growing plants and not open to the public, provided that the height of the greenhouse at the ridge does not exceed 30 feet (9144 mm) above grade. |
| 4. Screens shall not be required within individual dwelling units in Groups R-2, R-3 and R-4 where fully tempered glass is used as single glazing or as both panes in an insulating glass unit, and the following conditions are met: |
| 4.1. Each pane of the glass is 16 square feet (1.5 m2) or less in area. |
| 4.2. The highest point of the glass is 12 feet (3658 mm) or less above any walking surface or other accessible area. |
| 4.3. The glass thickness is 3/16 inch (4.8 mm) or less. |
| 5. Screens shall not be required for laminated glass with a 15 mil (0.38 mm) polyvinyl butyral (or equivalent) interlayer within the following limits: |
| 5.1. Each pane of glass is 16 square feet (1.5 m2) or less in area. |
| 5.2. The highest point of the glass is 12 feet (3658 mm) or less above a walking surface or other accessible area. |
[Statutory Authority: RCW
19.27.031 and
19.27.074. WSR 10-03-097, § 51-50-2400, filed 1/20/10, effective 7/1/10.]