PDFWAC 51-50-2400

Chapter 24—Glass and glazing.

Section 2405—Sloped glazing and skylights.
2405.3 Screening. Where used in monolithic glazing systems, heat-strengthened glass and fully tempered glass shall have screens installed below the glazing material. The screens and their fastenings shall:
(1) Be capable of supporting twice the weight of the glazing;
(2) Be firmly and substantially fastened to the framing members; and
(3) Be installed within 4 inches (102 mm) of the glass. The screens shall be constructed of a noncombustible material not thinner than No. 12 B&S gage (0.0808 inch) with mesh not larger than 1 inch by 1 inch (25 mm by 25 mm). In a corrosive atmosphere, structurally equivalent noncorrosive screen materials shall be used. Heat strengthened glass, fully tempered glass and wired glass, when used in multiple-layer glazing systems as the bottom glass layer over the walking surface, shall be equipped with screening that conforms to the requirements for monolithic glazing systems.
EXCEPTIONS:
In monolithic and multiple-layer sloped glazing systems, the following applies:
 
1. Fully tempered glass installed without protective screens where glazed between intervening floors at a slope of 30 degrees (0.52 rad) or less from the vertical plane shall have the highest point of the glass 10 feet (3048 mm) or less above the walking surface.
 
2. Screens are not required below any glazing material, including annealed glass, where the walking surface below the glazing material is permanently protected from the risk of falling glass or the area below the glazing material is not a walking surface.
 
3. Any glazing material, including annealed glass, is permitted to be installed without screens in the sloped glazing systems of commercial or detached noncombustible greenhouses used exclusively for growing plants and not open to the public, provided that the height of the greenhouse at the ridge does not exceed 30 feet (9144 mm) above grade.
 
4. Screens shall not be required within individual dwelling units in Groups R-2, R-3 and R-4 where fully tempered glass is used as single glazing or as both panes in an insulating glass unit, and the following conditions are met:
 
4.1. Each pane of the glass is 16 square feet (1.5 m2) or less in area.
 
4.2. The highest point of the glass is 12 feet (3658 mm) or less above any walking surface or other accessible area.
 
4.3. The glass thickness is 3/16 inch (4.8 mm) or less.
 
5. Screens shall not be required for laminated glass with a 15 mil (0.38 mm) polyvinyl butyral (or equivalent) interlayer within the following limits:
 
5.1. Each pane of glass is 16 square feet (1.5 m2) or less in area.
 
5.2. The highest point of the glass is 12 feet (3658 mm) or less above a walking surface or other accessible area.
[Statutory Authority: RCW 19.27.031 and 19.27.074. WSR 10-03-097, § 51-50-2400, filed 1/20/10, effective 7/1/10.]