EXCEPTION: | The roof structure shall be deemed adequate to support the load of the rooftop solar photovoltaic system if all of the following requirements are met: |
1. The solar photovoltaic panel system shall be designed for the wind speed of the local area, and shall be installed per the manufacturer's specifications. | |
2. The ground snow load does not exceed 70 pounds per square foot. | |
3. The total dead load of modules, supports, mountings, raceways, and all other appurtenances weigh no more than 4 pounds per square foot. | |
4. Photovoltaic modules are not mounted higher than 18 inches above the surface of the roofing to which they are affixed. | |
5. Supports for solar modules are to be installed to spread the dead load across as many roof-framing members as needed, so that no point load exceeds 50 pounds. |