EXCEPTION: | A habitable attic shall not be considered a story above grade plane provided that the habitable attic meets all the following requirements: |
| 1. The aggregate area of the habitable attic is not greater than one-half of the floor area of the story below. |
| 2. The habitable attic is located within a dwelling unit equipped with a fire sprinkler system in accordance with Section P2904 or NFPA 13D. |
| 3. The occupiable space is enclosed by the roof assembly above, knee walls (if applicable) on the sides and the floor-ceiling assembly below. |
| 4. The floor of the habitable attic shall not extend beyond the exterior walls of the story below. |
R326.4 Means of egress. The means of egress for habitable attics shall comply with the applicable provisions of Section R311.