Certificate of Competency Holder Requirements |
Certificate of Competency Level | Application Required | Certification or Exam Required | Stamp Issued | Type of work performed by Certificate of Competency Holder |
Level 1 | Yes | NICET Level 2 or pass an exam (See WAC 212-80-093 (1)(a)) | Yes | Designs NFPA 13D fire sprinkler systems (NFPA 25) for NFPA 13D |
Level 2 | Yes | NICET Level 2 (See WAC 212-80-093 (1)(b)) | Yes | Designs NFPA 13D, 13R or certain NFPA 24 (Restricted to only certain NFPA 13R systems, see WAC 212-80-018 (1)(b)) fire sprinkler systems (NFPA 25) for NFPA 13D or 13R |
Level 3 | Yes | NICET Level 3 or 4 (See WAC 212-80-093 (1) (c)) | Yes | Designs NFPA 13, 13D, 13R or 24 fire sprinkler systems (NFPA 25) for NFPA 13, 13D or 13R |
Level "U" | Yes | Pass an exam (See WAC 212-80-093 (1) (d)) | Yes | Supervises or performs the underground installation of fire sprinkler system piping |
Inspection, Testing Technician (ITT) Employed by an Inspection & Testing Contractor | Yes | NICET Level 2 or ASSE 15010 (See WAC 212-80-093 (1) (e)) | No | Performs inspection or testing on NFPA 13R or 13, wet and dry pipe fire protection systems only |
Inspection, Testing Technician (ITT) Employed by a Level 2 Contractor | Yes | NICET Level 2 or ASSE 15010 (See WAC 212-80-093 (1) (e)) | No | Performs inspection and testing on NFPA 13R or 13, wet and dry pipe fire protection systems only |
Inspection, Testing Technician (ITT) Employed by a Level 3 Contractor | Yes | NICET Level 2 or ASSE 15010 (See WAC 212-80-093 (1) (e)) | No | Same as ITT above and includes the testing of other fire protection systems such as preaction, deluge, foam, or fire pump |
Professional Engineer (P.E.) Licensed in Washington State | Only if acting as a Level 1, 2 or 3 certificate of competency holder | Licensed with department of licensing | By DOL unless acting as a Level 1, 2, or 3 certificate of competency holder | Designs, evaluates or consults on fire protection fire sprinkler systems |
(3) All information submitted by an applicant to the director to apply for a certificate must be true and accurate. If the director finds that information or documents submitted by an applicant is false, misleading, or has been altered in an effort to meet the requirements provided by this chapter, the finding will constitute a Level 3 violation.
(4) A violation of this section that involves a contractor allowing an employee to engage in performing fire protection sprinkler system work:
(a) Without a license or certificate, or with a license or certificate that has been expired for one or more years is a Level 3 violation.
(b) With a license or certificate that has been expired for more than 90 days and less than one year is a Level 2 violation.
(c) With a license or certificate that has been expired less than 90 days is a Level 1 violation.
[Statutory Authority: Chapters
18.160 and
18.270 RCW. WSR 22-22-072, § 212-80-093, filed 10/31/22, effective 1/1/23. Statutory Authority: RCW
18.270.900 and
18.160.030. WSR 19-24-059, § 212-80-093, filed 11/27/19, effective 12/28/19; WSR 17-10-031, § 212-80-093, filed 4/26/17, effective 5/27/17; WSR 14-03-019, § 212-80-093, filed 1/7/14, effective 2/7/14. Statutory Authority: RCW
18.270.900. WSR 09-01-114, § 212-80-093, filed 12/19/08, effective 1/19/09. Statutory Authority: Chapters
43.43 and
18.160 RCW. WSR 05-17-099, § 212-80-093, filed 8/16/05, effective 9/16/05; WSR 05-05-006, amended and recodified as § 212-80-093, filed 2/4/05, effective 3/7/05. Statutory Authority: Chapters
43.63A and
18.160 RCW. WSR 94-24-032, § 212-80-045, filed 12/1/94, effective 1/1/95; WSR 91-14-086 (Order 91-06), § 212-80-045, filed 7/1/91, effective 8/1/91.]