For all hardware, inspect for the following: |
Missing or illegible identification. |
Indications of heat damage, including weld spatter or arc strikes. |
Excessive pitting or corrosion. |
Load bearing components that are: |
| • | Bent; |
| • | Twisted; |
| • | Distorted; |
| • | Stretched; |
| • | Elongated; |
| • | Cracked; |
| • | Broken. |
Excessive nicks or gouges. |
10% reduction of the original or catalog dimension at any point. |
Excessive thread damage or wear, where applicable. |
Evidence of unauthorized welding or modification. |
Any other conditions that cause doubt as to the safety of continued use. |
On shackles, also inspect for incomplete pin engagement. |
On swivels and swivel hoist rings, check for lack of ability to freely rotate or pivot. |
On compression hardware, also check for: |
| Unauthorized replacement components; |
| Insufficient number of wire rope clips; |
| Improperly tightened wire rope clips; |
| Damaged wire rope; |
| Indications of wire rope slippage; |
| Improper assembly. |
On swivels, check for loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices. |
On blocks check for: |
| – | Loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices; |
| – | Misalignment or wobble in sheaves; |
| – | Excessive sheave groove corrugation or wear. |
(13) Any alteration or modification of rigging hardware must be in accordance with the hardware manufacturer or a qualified person and proof load tested to 125%. This test must be documented and available upon request.
(14) Welding of rigging hardware is prohibited unless authorized by the manufacturer or an RPE.
(15) Replacement parts must meet or exceed the original rigging hardware manufacturer's specifications.
(16) Rigging hardware selection must have the characteristics suitable for the application and environment where it will be used.
(17) Workers must keep all parts of their body from between the load and any rigging during the lift.
(18) If handling intermodal shipping containers at a construction site, you must follow the requirements in chapter
296-56 WAC, longshore, stevedore and waterfront related operations, Part F, Specialized terminals and the guidelines found in International Organization for Standardization (ISO) 3874 - Series 1 Freight Containers, fifth edition - Handling and Securing.
[Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050,
49.17.060. WSR 16-09-085, § 296-155-33705, filed 4/19/16, effective 5/20/16. Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050,
49.17.060 and chapter
49.17 RCW, and 29 C.F.R. 1926, Subpart CC. WSR 13-02-068, § 296-155-33705, filed 12/31/12, effective 2/1/13.]