(1) General requirements.
(a) You must guard exposed moving parts such as gears, projecting screws, setscrews, chain, cables, chain sprockets, and reciprocating or rotating parts, which constitute a hazard.
(b) All controls used during the normal operation cycle must be located within easy reach of the operator's station.
(c) Electric motor operated hoists must be provided with:
(i) A device to disconnect all motors from the line upon power failure and not permit any motor to be restarted until the controller handle is brought to the "off" position;
(ii) Where applicable, an overspeed preventive device;
(iii) A means whereby remotely operated hoists stop when any control is ineffective.
(d) All base-mounted drum hoists in use must meet the applicable requirements for design, construction, installation, testing, inspection, maintenance, and operation, as prescribed by the manufacturer.
(2) Specific requirements. (Reserved.)