Note: | 1. Use required cleaning and disinfecting procedures in WAC 296-842-22015, or the manufacturer's procedures that: |
| a. Result in a clean and sanitary respirator; |
| b. Do not damage the respirator; |
| c. Do not harm the user. |
| 2. Automated cleaning and disinfecting are permitted. |
| 3. Cleaning and disinfecting may be done by a central facility as long as you make sure respirators provided are clean, sanitary, and function properly. |
(3) Make sure respirators are assembled properly after cleaning or disinfecting.
Table 8
Required Frequencies for Cleaning and Disinfecting Respirators
If the respirator will be … | Then clean and disinfect the respirator … |
• Used exclusively by one employee | • As often as needed to: |
| | – Keep it clean and functional; and |
| | – To prevent health hazards such as skin irritation |
• Shared for nonemergency use; or | • Before it is worn by another employee |
• Used for fit-testing or training | |
• Shared for emergency use | • After each use so the respirator is immediately ready for use at all times |
[Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050, and
49.17.060. WSR 17-18-075, § 296-842-17005, filed 9/5/17, effective 10/6/17. Statutory Authority: RCW
49.17.050 and 29 C.F.R. Subpart Z. WSR 09-19-119, § 296-842-17005, filed 9/22/09, effective 12/1/09. Statutory Authority: RCW
49.17.010,
49.17.040,
49.17.050,
49.17.060. WSR 07-05-072, § 296-842-17005, filed 2/20/07, effective 4/1/07; WSR 03-20-114, § 296-842-17005, filed 10/1/03, effective 1/1/04.]