(Effective until March 15, 2024)
Section 1105—Accessible entrances.
1105.1.8 Automatic doors. In facilities with the occupancies and building occupant loads indicated in Table 1105.1.8, all public entrances that are required to be accessible shall have one door be either a full power-operated door or a low-energy power-operated door. Where the public entrance includes a vestibule, at least one door into and one door out of the vestibule shall meet the requirements of this section.
Table 1105.1.8a
PUBLIC ENTRANCE WITH POWER-OPERATED DOORSa
Occupancy | Building Occupant Load Greater Than |
A-1, A-2, A-3, A-4 | 300 |
B, M, R-1 | 500 |
a | In mixed-use facilities containing occupancies listed, when the total sum of the occupant load is greater than those listed, the most restrictive building occupant load shall apply. |
[Statutory Authority: RCW
19.27.031 and
19.27.074. WSR 20-01-090, § 51-50-11050, filed 12/12/19, effective 7/1/20.]