PERMANENT RULES
LABOR AND INDUSTRIES
Effective Date of Rule: March 1, 2006.
Purpose: The department rewrote and clarified requirements relating to fire brigades. The department repealed the rules in chapter 296-24 WAC and adopted fire brigades as new chapter 296-811 WAC. This rule making is part of our goal to rewrite all of WISHA's general occupational safety and health rules for clarity.
AMENDED SECTIONS:
WAC 296-78-71011 Egress and exit.
| Added a reference to the new fire brigade chapter. |
| Updated a reference. |
| Updated a reference. |
| Chapter 296-811 WAC, Fire brigades. |
WAC 296-811-100 Scope.
| Added language to this section relating to what this chapter covers. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| This section requires that a written fire brigade statement is available for inspection by employees. Elements of this statement are located in this section. |
| The requirements in this section were located in WAC 296-24-58507. No new requirements have been added. |
| This section requires that brigade members who are assigned to fight interior structural fires are physically capable of doing that activity. |
| The requirements in this section were located in WAC 296-24-58507 and 296-24-58517. No new requirements have been added. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| This section requires written procedures to be developed relating to the special hazards of a fire brigade. |
| The requirements in this section were located in WAC 296-24-58509. No new requirements have been added. |
| This section requires firefighting training. |
| The requirements in this section were located in WAC 296-24-58509 and 296-24-58517. No new requirements have been added. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| This section requires providing and maintaining firefighting equipment. |
| The requirements in this section were located in WAC 296-24-58511. No new requirements have been added. |
| This section requires providing appropriate personnel protective equipment for fire brigade members. |
| The requirements in this section were located in WAC 296-24-58513. No new requirements have been added. |
| This section contains requirements relating to SCBAs. |
| The requirements in this section were located in WAC 296-24-58515 and 296-24-58517. No new requirements have been added. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| This section contains the requirements in an "Immediately Dangerous to Life or Health" (IDLH) and standby assistance situation. |
| The requirements in this section were located in WAC 296-24-58516. No new requirements have been added. |
| This section contains applicable definitions relating to fire brigades. They are: Approved, buddy-breathing device, education, extinguisher classification, extinguisher rating, fire brigade, fire classifications, flammable, incipient fire stage, inspection, interior structural firefighting, maintenance, positive-pressure breathing apparatus, quick-disconnect valve, and training. |
WAC 296-24-58505 Fire brigades, 296-24-58507 Organization,
296-24-58509 Training and education, 296-24-58511 Fire
fighting equipment, 296-24-58513 Protective clothing,
296-24-58515 Respiratory protection devices, 296-24-58516
Procedures for interior structural fire fighting, and
296-24-58517 Appendix A -- Fire brigades.
| Requirements in this section were moved to chapter 296-811 WAC, Fire brigades. |
Citation of Existing Rules Affected by this Order: Repealing WAC 296-24-58505, 296-24-58507, 296-24-58509, 296-24-58511, 296-24-58513, 296-24-58515, 296-24-58516 and 296-24-58517; and amending WAC 296-78-71011, 296-79-040, and 296-305-01003.
Statutory Authority for Adoption: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060.
Adopted under notice filed as WSR 05-19-085 on September 20, 2005.
Changes Other than Editing from Proposed to Adopted Version: There are no costs to assess on the changes from proposed to adopted.
WAC 296-811-200 Section contents.
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| Added a title to this contents page. It is called "Establishing a fire brigade." |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| Added a title to this contents page. It is called "Training." |
| This section requires firefighting training. |
| The requirements in this section were located in WAC 296-24-58509 and 296-24-58517. No new requirements have been added. |
| Added the words "You must" in between the second and third bullets. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| Added a title to this contents page. It is called "Equipment." |
| This section requires providing and maintaining firefighting equipment. |
| The requirements in this section were located in WAC 296-24-58511. No new requirements have been added. |
| In the table added the words "and after each use" after the phrase "Inspect at least every month." |
| This section contains requirements relating to SCBAs. |
| The requirements in this section were located in WAC 296-24-58515 and 296-24-58517. No new requirements have been added. |
| Fixed the spelling error of the word "apparatus." |
| In the second bullet, second subbullet, deleted the words "or can be set that way when used for interior structural fire fighting." |
| Deleted the subbullet that read, "Have the same capacity and pressure ratings as the SCBA's original cylinder(s)." |
| Spelled out the acronyms for department of transportation and National Institute for Occupational Safety and Health. |
| This section is a short table of contents of the sections located in this three-digit WAC number. |
| Added a title to this contents page. It is called "Requirements during firefighting." |
| This section contains the requirements in an "Immediately Dangerous to Life or Health" (IDLH) and standby assistance situation. |
| The requirements in this section were located in WAC 296-24-58516. No new requirements have been added. |
| In the second bullet, replaced the word "section" with "chapter." |
| Added a reference that reads, "More information on interior structural fires is located in another chapter, WAC 296-305-05001 Emergency fireground operations -- Structural." |
| This section contains applicable definitions relating to fire brigades. They are: |
| In the definition of "Incipient fire stage" deleted the words "or Class II standpipe." |
| In the definition of "Positive-pressure breathing apparatus" changed the name of this definition to "Self-contained breathing apparatus (SCBA)." |
| Deleted the definition for "Quick-disconnect valve." |
Number of Sections Adopted in Order to Comply with Federal Statute: New 0, Amended 0, Repealed 0; Federal Rules or Standards: New 14, Amended 3, Repealed 8; or Recently Enacted State Statutes: New 0, Amended 0, Repealed 0.
Number of Sections Adopted at Request of a Nongovernmental Entity: New 0, Amended 0, Repealed 0.
Number of Sections Adopted on the Agency's Own Initiative: New 14, Amended 3, Repealed 8.
Number of Sections Adopted in Order to Clarify, Streamline, or Reform Agency Procedures: New 14, Amended 3, Repealed 8.
Number of Sections Adopted Using Negotiated Rule Making: New 0, Amended 0, Repealed 0; Pilot Rule Making: New 0, Amended 0, Repealed 0; or Other Alternative Rule Making: New 14, Amended 3, Repealed 8.
Date Adopted: December 20, 2005.
Gary Weeks
Director
OTS-8316.3
FIRE BRIGADES
Definition:
A fire brigade is an organized group of employees whose primary employment is other than fire fighting but who are knowledgeable, trained, and skilled in specialized fire fighting operations based on site-specific hazards present at a single commercial facility or facilities under the same management.
Note: | Nothing in this chapter requires you to establish an employee fire brigade. |
[]
Your responsibility:
To decide on brigade functions in the workplace and make sure brigade members are capable of doing them.
Organizing statement
Physical capability of brigade members
[]
You must:
Develop a written fire brigade policy that is available for inspection by employees or their designated representatives, that covers all of the following:
The role and responsibilities of the fire brigade in the workplace.
The basic organizational structure of the fire brigade.
The number of brigade members.
Type, amount, and frequency of training for brigade members according to the section Fire fighting training, WAC 296-811-30010, in this chapter.
Note: | You may also want to include: |
Descriptions of brigade member duties. | |
Line authority of each brigade officer. | |
Number of brigade officers. | |
Number of training instructors. |
[]
You must:
Make sure brigade members who are assigned to fight interior structural fires are physically capable of doing this activity.
Do not permit employees with known physical limitations that can be reasonably identified, such as heart disease or seizure disorder, to participate in structural fire fighting activities unless the employee has been released by a physician to do so.
Note: | Not all brigade members need to be physically capable of fighting interior structural fires. Brigade members who are not physically capable of fighting interior structural fires may be assigned to other brigade duties that match their physical capabilities, such as pump operation or fire prevention inspection. |
[]
Your responsibility:
To inform brigade members of special hazards in the workplace and train them for their brigade functions.
Special hazards
Fire fighting training
[]
You must:
Develop, include in training, and make available to brigade members, written procedures that describe the following:
The special hazards they may encounter in their workplace.
The actions they need to take in situations that involve these hazards.
Inform brigade members of any changes to those hazards, or the actions to take, when changes happen.
Examples of special hazards include storing and using flammable liquids and gases, toxic chemicals, and radioactive substances.
[]
You must:
Make sure training that a brigade member receives elsewhere that meets one or more requirements in Table 1, Training for brigade members, has been:
Received within the past year;
Documented as having been received, such as with a completion certificate.
Provide training frequently enough to keep brigade members able to do their functions satisfactorily and safely.
Note: | You may choose to train more often, monthly or even weekly, for some equipment or techniques. Consult fire training resources, such as the International Fire Service Training Association, the National Fire Protection Association (NFPA), or the International Society of Fire Service Instructors, for recommendations about fire training schools or programs. |
Make sure brigade members are trained according to Table 1, Training for Brigade Members.
Table 1: Training for Brigade Members
For these brigade members | Provide training that is | At these times | ||
All brigade members, including leaders, trainers, and incident commanders. | | Appropriate to their assigned duties and functions. | | Initially before they do any fire brigade emergency activities; |
| Appropriate to special hazards in the workplace. | AND | ||
| Similar to that of reputable fire training schools. | | Every year after initial training. | |
| A combination of hands-on and classroom experiences. | |||
| Suited to the industry you are part of, such as oil refining or chemical processing. | |||
Brigade members assigned to do interior structural fire fighting. | All of the above plus the following: | At the above times plus the following: | ||
| Specific training in interior structural fire fighting. | | Every quarter. | |
Brigade members assigned as leaders, training instructors, or both. | All of the above plus the following: | As needed to maintain their expertise at a higher level than that of other brigade members. | ||
| Additional training that is more comprehensive than that of other brigade members and appropriate to their assigned duties and functions. |
[]
Your responsibility:
To provide brigade members with equipment and protective clothing appropriate for their brigade functions.
Fire fighting equipment
Protective clothing
Respiratory protective devices
[]
You must:
Provide appropriate fire fighting equipment for the fire brigade.
Inspect and maintain brigade fire fighting equipment according to Table 2, Fire Brigade Equipment Inspection and Maintenance.
Table 2: Fire Brigade Equipment Inspection and Maintenance
For this equipment | Do the following | |
All brigade fire fighting equipment. | | Inspect at least every year. |
| Maintain in safe operating condition. | |
| Replace if damaged or in unsafe condition. | |
Brigade respirators and portable fire extinguishers. | Inspect at least every month and after each use. |
[]
You must:
Provide appropriate protective clothing for fire brigade members who do interior structural fire fighting. Make sure protective clothing is:
Provided at no cost.
Meets the requirements for foot, body, hand, eye, face, and head protection found in another chapter, Safety standards for fire fighters, chapter 296-305 WAC.
Exemption: | Protective clothing requirements do not apply to the following fire brigade members: |
Those who don't perform interior structural fire fighting. | |
Those who use only standpipe systems or portable fire extinguishers to control or put out fires that are in the incipient stage only. |
[]
You must:
Provide SCBAs, other than escape self-contained breathing apparatus' (ESCBAs), and make sure they are used by fire brigade members who do interior structural fire fighting.
Make sure SCBAs do the following:
Meet the requirements found in another chapter, Respirators, chapter 296-842 WAC.
Are positive-pressure or pressure-demand type.
Use only compressed-air cylinders that:
&sqbul; Meet department of transportation (DOT) and the National Institute for Occupational Safety and Health (NIOSH) requirements.
Have a service life of at least thirty minutes, as required by 42 CFR, Part 84.
Have an automatic alarm that can be heard when seventy-five to eighty percent of its service life has been used up.
Note: | An SCBA can have a quick-disconnect valve or "buddy breathing" accessory only if the valve or accessory does not do any of the following: |
Damage the SCBA. | |
Restrict the SCBA's air flow. | |
Interfere with the SCBA's normal operation. | |
The "buddy breathing" accessory or quick-disconnect valve need not be certified by NIOSH. |
[]
Your responsibility:
To make sure brigade members use safe practices during interior structural fire fighting.
Brigade members in interior structural fires
[]
IMPORTANT:
Nothing in this section is meant to prevent fire brigade members assigned to respond to fires from rescue activities in an immediately dangerous to life and health (IDLH) atmosphere before the whole team assigned to respond to fires has arrived.
You must:
Make sure at least two qualified fire brigade members go together into an IDLH atmosphere and remain in visual or voice contact with each other at all times.
Maintain standby assistance, with two people, as required by another section, Standby requirements for immediately dangerous to life or health (IDLH) conditions, WAC 296-842-19005.
Note: | One of the two brigade members providing standby assistance can be assigned another role, such as safety officer, as long as the safety or health of any fire fighter working the incident will not be jeopardized if the brigade member becomes unavailable through giving assistance or rescue. |
Reference: | More information on interior structural fires is located in another section, WAC 296-305-05001, Emergency fireground operations -- Structural. |
[]
Buddy-breathing device
An equipment accessory for self-contained breathing apparatus (SCBA) that permits a second person (a "buddy") to share the air supply used by the SCBA wearer.
Extinguisher classification
The letter classification given an extinguisher to designate the class or classes of fires on which that extinguisher will be effective. For example, use a Class A extinguisher on a Class A fire. See also fire classifications.
Portable fire extinguishers are classified for use on certain classes of fires and are rated within that class for relative extinguishing effectiveness at a temperature of plus 70°F by nationally recognized testing laboratories. This is based upon fire classifications and fire extinguishment potentials as determined by fire tests.
Note: | The classification and rating system described in this section is used by Underwriters' Laboratories, Inc., and Underwriters' Laboratories of Canada, and is based on extinguishing preplanned fires of determined size and description as follows: |
Extinguisher Class | Fire Test for Classification and Rating |
Class A | Wood and excelsior fires excluding deep-seated conditions. |
Class B | Two-inch depth gasoline fires in square pans. |
Class C | No fire test. Agent must be a nonconductor of electricity. |
Class D | Special tests on specific combustible metal fires. |
The numerical rating, such as 2A, given to an extinguisher that indicates the extinguishing potential of the unit based on standardized tests developed by Underwriters' Laboratories, Inc.
Fire brigade
An organized group of employees whose primary employment is other than fire fighting but who are knowledgeable, trained, and skilled in specialized fire fighting operations based on site-specific hazards present at a single commercial facility or facilities under the same management.
Fire classifications
Fires are classified based on the types of burning materials:
Fire Class | Types of Burning Materials |
Class A | Fires involving ordinary combustible materials such as paper, wood, cloth, and some rubber and plastic materials. |
Class B | Fires involving flammable or combustible liquids, flammable gases, greases, and similar materials, and some rubber and plastic materials. |
Class C | Fires involving energized (live) electrical equipment where it is important that the extinguishing agent not conduct electricity. (When electrical equipment is de-energized, it is safe to use an extinguisher for Class A or B fires on it, since electricity is not an issue then.) |
Class D | Fire involving combustible metals such as magnesium, titanium, zirconium, sodium, lithium, and potassium. |
A fire in the beginning stage that can be controlled or put out by portable fire extinguishers, or small hose systems, without the need for protective clothing or breathing apparatus.
Inspection
A visual check of fire protection systems and equipment to ensure they are in place, charged, and ready for use if there is a fire.
Interior structural fire fighting
The physical activity of suppressing fire, rescuing people, or both, inside buildings or enclosed structures involved in a fire that is past the incipient stage.
Maintenance
Servicing fire protection equipment and systems to ensure they will perform as expected if there is a fire. Maintenance differs from inspection in that maintenance requires checking internal fittings, devices, and agent supplies, as well as correcting deficiencies found.
Self-contained breathing apparatus (SCBA)
Self-contained breathing apparatus (SCBA) in which the air pressure in the breathing zone is higher than that of the immediate environment during both inhaling and exhaling.
[]
OTS-8313.1
AMENDATORY SECTION(Amending WSR 03-06-076, filed 3/4/03,
effective 8/1/03)
WAC 296-78-71011
Egress and exit.
(1) In all enclosed
buildings, means of egress shall be provided in accordance
with the provisions of WAC 296-800-310.
(2) All swinging doors shall be provided with windows, the bottom of which shall be not more than forty-eight inches above the floor. One window shall be provided for each section of double swinging doors. All such windows shall be of shatter proof or safety glass unless otherwise protected against breakage.
(3) Outside exits shall open outward. Where sliding doors are used as exits, an inner door not less than two feet six inches by six feet shall be cut inside each of the main doors and arranged to open outward.
(4) At least two fire escapes or substantial outside stairways, shall be provided for mill buildings where the floor level is more than eight feet above the ground.
(a) Buildings over one hundred fifty feet in length shall have at least one additional fire escape or substantial outside stairway for each additional one hundred fifty feet of length or fraction thereof.
(b) Passageways to fire escapes or outside stairways shall be marked and kept free of obstructions at all times.
(c) Fire protection. The requirements of ((Part G2 (Fire
Protection) and Part G3 (Fire Suppression Equipment),))
chapter 296-24 WAC, Part G-3 of the general safety and health
standard, and WAC 296-800-300 of the safety and health core
rules, and chapter 296-811 WAC, Fire brigades, shall be
complied with in providing the necessary fire protection for
sawmills.
(d) Fire drills shall be held at least quarterly and shall be documented.
(5) Where a doorway opens upon a roadway, railroad track, or upon a tramway or dock over which vehicles travel, a barricade or other safeguard and a warning sign shall be placed to prevent workers from stepping directly into moving traffic.
(6) Tramways and trestles shall be substantially supported by piling or framed bent construction which shall be frequently inspected and maintained in good repair at all times. Tramways or trestles used both for vehicular and pedestrian traffic shall have a walkway with standard hand rail at the outer edge and shear timber on the inner edge, and shall provide three feet clearance to vehicles. When walkways cross over other thoroughfares, they shall be solidly fenced at the outer edge to a height of 42 inches over such thoroughfares.
(7) Where tramways and trestles are built over railroads they shall have a vertical clearance of twenty-two feet above the top of the rails. When constructed over carrier docks or roads, they shall have a vertical clearance of not less than six feet above the drivers foot rest on the carrier, and in no event shall this clearance be less than twelve feet from the surface of the lower roadway or dock.
(8) Walkways (either temporary or permanent) shall be not less than twenty-four inches wide and two inches thick, nominal size, securely fastened at each end. When such walkways are used on an incline the angle shall not be greater than twenty degrees from horizontal.
(9) Walkways from the shore or dock to floats or barges shall be securely fastened at the shore end only and clear space provided for the other end to adjust itself to the height of the water.
(10) Cleats of one by four inch material shall be fastened securely across walkways at uniform intervals of eighteen inches whenever the grade is sufficient to create a slipping hazard.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 03-06-076, § 296-78-71011, filed 3/4/03, effective 8/1/03. Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. 01-11-038, § 296-78-71011, filed 5/9/01, effective 9/1/01. Statutory Authority: RCW 49.17.040, 49.17.050 and 49.17.240. 81-18-029 (Order 81-21), § 296-78-71011, filed 8/27/81.]
OTS-8314.1
AMENDATORY SECTION(Amending WSR 01-11-038, filed 5/9/01,
effective 9/1/01)
WAC 296-79-040
Fire protection, ignition sources and
means of egress.
For fire protection, ignition source, and
means of egress requirements see chapter 296-24 WAC, Parts
G-1((, G-2)) and G-3 ((and)), WAC 296-800-300 of the safety
and health core rules, and chapter 296-811 WAC, Fire brigades.
[Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. 01-11-038, § 296-79-040, filed 5/9/01, effective 9/1/01; 99-16-083, § 296-79-040, filed 8/3/99, effective 11/3/99; Order 74-24, § 296-79-040, filed 5/6/74; Order 70-6, § 296-79-040, filed 7/10/70, effective 8/10/70.]
OTS-8315.1
AMENDATORY SECTION(Amending WSR 01-11-038, filed 5/9/01,
effective 9/1/01)
WAC 296-305-01003
Scope and application.
(1) The rules
of this chapter shall apply with respect to any and all
activities, operations and equipment of employers and
employees involved in providing fire protection services which
are subject to the provisions of the Washington Industrial
Safety and Health Act of 1973 (chapter 49.17 RCW).
(2) The provisions of this chapter apply to all fire fighters and their work places, including the fire combat scene. Although enforcement of applicable standards will result from provable violations of these standards at the fire combat scene, agents of the department will not act in any manner that will reduce or interfere with the effectiveness of the emergency response of a fire fighting unit. Activities directly related to the combating of a fire will not be subjected to the immediate restraint provisions of RCW 49.17.130.
(3) In the development of this document many consensus standards of the industry were considered and evaluated as to adaptability to the Washington state fire service industry. Where adaptable and meaningful, the fire fighter safety elements of these standards were incorporated into this WAC. Chapter 296-305 WAC, shall be considered as the fire fighter safety standards for the state of Washington.
(4) The provisions of this chapter cover existing requirements that apply to all fire departments. All fire departments shall have in place their own policy statement and operating instructions that meet or exceed these requirements. This chapter contains state and/or federal performance criteria that fire departments shall meet.
(5) Unless specifically stated otherwise by rule, if a duplication of regulations, or a conflict exists between the rules regulating wildland fire fighting and other rules in the chapter, only the rules regulating wildland fire fighting shall apply to wildland fire fighting activities and equipment.
(6) The provisions of this chapter shall be supplemented
by the provisions of the general safety and health standards
of the department of labor and industries, chapters 296-24
(((including Part G-2, Fire protection))), 296-62 ((and)),
296-800, and 296-811 WAC. In the event of conflict between
any provision(s) of this chapter and any provision(s) of the
general safety and health standards, the provision(s) of this
chapter shall apply.
(7) The provisions of this standard do not apply to
industrial fire brigades, as defined in this chapter. Industrial fire brigades are covered under the provisions of
chapter ((296-24 WAC, Part G-2, Fire protection)) 296-811 WAC,
Fire brigades.
[Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. 01-11-038, § 296-305-01003, filed 5/9/01, effective 9/1/01. Statutory Authority: RCW 49.17.040. 99-05-080, § 296-305-01003, filed 2/17/99, effective 6/1/99. Statutory Authority: RCW 49.17.010, [49.17].050 and [49.17].060. 96-11-067, § 296-305-01003, filed 5/10/96, effective 1/1/97.]
OTS-8312.1
REPEALER
The following sections of the Washington Administrative Code are repealed:
WAC 296-24-58505 | Fire brigades. |
WAC 296-24-58507 | Organization. |
WAC 296-24-58509 | Training and education. |
WAC 296-24-58511 | Fire fighting equipment. |
WAC 296-24-58513 | Protective clothing. |
WAC 296-24-58515 | Respiratory protection devices. |
WAC 296-24-58516 | Procedures for interior structural fire fighting. |
WAC 296-24-58517 | Appendix A -- Fire brigades. |