PERMANENT RULES
LABOR AND INDUSTRIES
Effective Date of Rule: September 1, 2006.
Purpose: The purpose of this rule making is to make this rule easy to read, understand and more usable for employers. This rule will place abrasive blasting requirements from chapter 296-24 WAC into chapter 296-818 WAC, Abrasive blasting. Also, references were updated. There are no anticipated effects.
NEW CHAPTER:
| Chapter 296-818 WAC, Abrasive blasting. |
WAC 296-818-100 Scope.
| Added language to this section relating to what this chapter covers. |
| This section is a short table of contents of the sections located in this 3-digit WAC number. |
| Moved requirements relating to dust hazards from WAC 296-24-67509 to this section. |
| Moved requirements relating to personal protective equipment from WAC 296-24-67507 and 296-24-67515 to this section. |
| Moved requirements relating to housekeeping from WAC 296-24-67519 to this section. |
| This section is a short table of contents of the sections located in this 3-digit WAC number. |
| Moved requirements relating to organic abrasives from WAC 296-24-67509 to this section. |
| Moved requirements relating to blast cleaning enclosures from WAC 296-24-67511, 296-24-67520, 296-62-11009, and 296-62-11013 to this section. |
| Moved requirements relating to blast cleaning enclosures from WAC 296-24-67509 and 296-24-67519 to this section. |
| This section is a short table of contents of the sections located in this 3-digit WAC number. |
| Moved requirements relating to construction of exhaust systems from WAC 296-24-67513 to this section. |
| Moved requirements relating to explosion venting and wiring from WAC 296-24-67509 to this section. |
| Moved requirements relating to inspection and maintenance from WAC 296-24-67513 to this section. |
| Moved definitions relating to abrasive blasting to this section. |
Citation of Existing Rules Affected by this Order:
AMENDED SECTIONS:
WAC 296-62-11015 Abrasive blasting.
| Update a reference. |
| Update references. |
WAC 296-24-675 Safe practices of abrasive blasting operations, 296-24-67501 Purpose, 296-24-67503 Application, 296-24-67505 Selection of abrasives and equipment, 296-24-67507 Definitions, 296-24-67509 Dust hazards from abrasive blasting, 296-24-67511 Blast cleaning enclosures, 296-24-67513 Construction and maintenance of the exhaust ventilation systems, 296-24-67515 Personal protective equipment, 296-24-67517 Air supply and air compressors, 296-24-67519 Operational procedures and general safety, 296-24-67520 Ventilation, and 296-24-67521 Appendix 1, move these sections to chapter 296-818 WAC. WAC 296-62-12007 Effective date, this section is no longer applicable.
Statutory Authority for Adoption: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060.
Adopted under notice filed as WSR 06-06-063 on February 28, 2006.
Changes Other than Editing from Proposed to Adopted Version:
WAC 296-818-30005 Combustible organic abrasive.
| Moved a bullet from WAC 296-818-30015 to this section. The bullet reads, "Bond and ground the blast nozzle to prevent the build up of static charges." |
| Deleted the third subbullet and moved it to WAC 296-818-30005. |
| Clarified the definitions of "Blast cleaning room" and "Exhaust ventilation system." |
Number of Sections Adopted in Order to Comply with Federal Statute: New 0, Amended 0, Repealed 0; Federal Rules or Standards: New 14, Amended 2, Repealed 14; or Recently Enacted State Statutes: New 0, Amended 0, Repealed 0.
Number of Sections Adopted at Request of a Nongovernmental Entity: New 0, Amended 0, Repealed 0.
Number of Sections Adopted on the Agency's Own Initiative: New 14, Amended 2, Repealed 14.
Number of Sections Adopted in Order to Clarify, Streamline, or Reform Agency Procedures: New 14, Amended 2, Repealed 14.
Number of Sections Adopted Using Negotiated Rule Making: New 0, Amended 0, Repealed 0; Pilot Rule Making: New 0, Amended 0, Repealed 0; or Other Alternative Rule Making: New 14, Amended 2, Repealed 14.
Date Adopted: June 6, 2006.
Gary Weeks
Director
OTS-8593.3
ABRASIVE BLASTING
Pneumatic pressure
Hydraulic pressure
Centrifugal force
References: | Depending on your work processes, here are examples of other chapters you may need: |
Safety and health core rules, chapter 296-800 WAC | |
Machine safety, chapter 296-806 WAC | |
Respiratory hazards, chapter 296-841 WAC | |
Respirators, chapter 296-842 WAC | |
Lead, chapter 296-857 WAC | |
Scaffolds, chapter 296-874 WAC | |
Cadmium, chapter 296-62 WAC | |
Part L, Electrical, chapter 296-24 WAC |
[]
Your responsibility:
To protect employees from hazards associated with their work environment
Dust hazards
Personal protective equipment (PPE)
Housekeeping
[]
IMPORTANT:
Abrasives and the surface coatings on materials blasted are shattered and pulverized during blasting operations. The dust formed will contain particles that could result in the following hazards:
Respiratory
Fire
Explosion
Wet blasting methods minimize dust exposure, but dispersed droplets, mists, and dried residues may become airborne and create potential exposures.
You must:
Evaluate the potential health hazards from abrasive blasting operations by considering the composition and toxicity of the abrasive material and the surface being abraded.
References: | For additional hazard assessment requirements, go to these separate chapters: |
Respirators, chapter 296-842 WAC | |
The Safety and health core rules, chapter 296-800 WAC | |
Personal protective equipment, WAC 296-800-16005. | |
For requirements on the use of Combustible organic abrasive, go to WAC 296-818-30005. |
Keep dust concentrations below the permissible exposure limits found in a separate chapter, Respiratory hazards, chapter 296-841 WAC.
Note: | When sampling for dust concentrations, place the sample collection device: |
In the breathing zone of the operator; | |
AND | |
Outside the respiratory protection worn. |
[]
You must:
Supply and make sure personal protective equipment is worn.
Follow the requirements in Table-1, Personal Protective Equipment (PPE).
PROVIDE | WHEN |
Abrasive Blasting Respirators | Operators work in any of the following situations: |
Inside blast cleaning rooms | |
Where silica sand is used in manual blasting operations | |
Where concentrations of toxic dust exceed the permissible exposure limits found in a separate chapter: | |
&sqbul; Respiratory hazards, WAC 296-841-20020, Table-3 "Exposure Limits for Air Contaminants" | |
Exemption: | |
An abrasive respirator does not need to be worn if the operator is physically separated from the nozzle and blast by an exhaust ventilated enclosure. | |
Definition: | |
Abrasive-blasting respirator | |
A supplied air or a continuous flow respirator constructed to cover and protect the operator's head, neck and shoulders from rebounding abrasive. | |
Eye and Face protection
to both of the following:
|
Respirators worn during blasting operations do not provide eye and face protection |
Personnel working near blasting operations | |
Gloves and Aprons made of heavy canvas or leather; | Operators are exposed to the impact of rebounding abrasives |
OR | |
Equivalent protection |
Notes: | Use only respirators certified by NIOSH in 42 C.F.R. Part 84 for protecting employees from dusts, and other hazards produced during abrasive blasting operations, like: |
Using a garnet sand to blast a concrete surface, resulting in crystalline silica dust | |
A filtering face piece may be used only for short, intermittent, or occasional dust exposures for any of the following tasks: | |
To protect the operator during abrasive blasting operations performed outside the enclosure or outdoors where nonsilica abrasives are used on materials with low toxicity | |
Clean-up | |
Dumping dust collectors | |
Unloading shipments of sand at receiving areas when the following controls are not feasible: | |
&sqbul; Enclosures | |
&sqbul; Exhaust ventilation | |
OR | |
&sqbul; Other means |
Reference: | For additional requirements to help you fully protect employees, go to the following separate chapters: |
The Safety and health core rules, chapter 296-800 WAC: | |
&sqbul; Personal protective equipment (PPE), WAC 296-800-160 | |
Respiratory hazards, chapter 296-841 WAC | |
Respirators, chapter 296-842 WAC: | |
&sqbul; Respirator program, WAC 296-842-120 | |
&sqbul; Specifications for air quality, WAC 296-842-200 |
[]
You must:
Keep aisles and walkways clear of steel shot or similar abrasives that may create a slipping hazard.
Prohibit the accumulation of dust on the floors or ledges outside blasting enclosures.
Clean up dust spills promptly.
Note: | Removal of accumulated dust should be done: |
With a high efficiency particulate air filter (HEPA), vacuum cleaner when the plant is not in operation; | |
AND | |
By a person wearing a respirator approved for the existing conditions |
Reference: | For additional housekeeping requirements, see the Safety and health core rules, chapter 296-800 WAC, Housekeeping, WAC 296-800-220. |
[]
Your responsibility:
To follow these operational requirements
Combustible organic abrasives
Blast cleaning enclosures
Blast cleaning nozzles
[]
IMPORTANT:
This section applies to blasting operations where flammable or explosive dust mixtures may be present.
You must:
Prohibit the use of combustible organic abrasives, except in automatic blast cleaning systems.
Bond and ground the blast nozzle to prevent the buildup of static charges.
Note: | Fine dust produced from combustible, organic abrasive is a fire and explosion hazard. |
[]
You must:
Install adequate ventilation systems in blast cleaning enclosures that are able to do all of the following:
Control concentrations of airborne contaminants below the permissible exposure limits that apply
Provide a continuous inward flow of air at all openings in the enclosure during blasting operations
Minimize the escape of dust into adjacent work areas
Maintain visibility in blast cleaning rooms and cabinets
Rapidly clear dust from the air after blasting stops
Discharge exhaust so contaminated air does not do either of the following:
&sqbul; Present a health hazard to any worker; or
&sqbul; Reenter buildings in harmful amounts
Make sure ventilation systems are designed and operated so employees are not exposed to excessive air velocities
Make sure make-up air systems do not interfere with the effectiveness of the exhaust system, and are designed to do both of the following:
Replace exhausted air in ample quantities
Temper make-up (supply) air when necessary
Do both of the following before opening the blast cleaning enclosure:
Turn the blast off
Run the exhaust system for a sufficient period of time to clear the air of dust particles
Follow the requirements in Table-2, Blast Cleaning Enclosures.
If you have | Then make sure |
Air inlets and access openings | They are either baffled or arranged so the combination of inward airflow and baffles minimizes both of the following: |
The escape of abrasive or dust particles into adjacent work areas. | |
Visible spurts of dust | |
Small access openings where dust might escape | Slit resistant baffles are installed in multiple sets at all small access openings, and do both of the following: |
Regularly inspect them | |
Replace them when needed | |
An observation window in enclosures where hard, deep cutting abrasives are used | The window is made of safety glass protected by screening |
Notes: | |
Hard, deep cutting abrasives may shatter normal glass. | |
If the safety glass shatters, the protective screening will help contain the glass and protect employees from cuts and lacerations. | |
Small operator access doors | They are flanged and tight when closed, and open from both inside and outside the enclosure. |
Note: | |
If you have a small operator access door and a large work access door, the large work access door may open or close from the outside only. |
References: | For more information on: |
Air velocities, refer to the following: | |
The latest edition of Recommended Industrial Ventilation Guidelines (ACGIH) | |
NIOSH 1976 Industrial Ventilation | |
Exit routes, go to the Safety and health core rules, WAC 296-800-310. |
[]
You must:
Make sure nozzles are all of the following:
Mounted on a support when not in use
Equipped with operating valves that are manually held open.
Note: | To help prevent the buildup of static charges, pressurized tanks used to supply abrasive should be: |
Connected to the manual control of the nozzle; | |
AND | |
Have the relief valve or opening located so it can safely vent. |
[]
Your responsibility:
To make sure exhaust ventilation systems meet these requirements
Construction
Explosion venting and wiring
Inspection and maintenance
[]
You must:
Make sure exhaust systems are constructed, installed, inspected, and maintained to meet both of the following:
The American National Standards Institute (ANSI), Z9.2-2001 for:
&sqbul; Fundamentals Governing the Design and Operation of Local Exhaust Systems
The National Fire Protection Association (NFPA) 91-2004 for:
&sqbul; Exhaust Systems for Air Conveying of Vapors, Gases and Noncombustible Particulate Solids.
Reference: | Refer to the American National Standards Institute, ANSI Z9.4-1997 for information on the following: |
Exhaust Systems for Abrasive-blasting Operations, Ventilation, and Safe Practices for Fixed Location Enclosures. |
[]
You must:
Follow the requirements in Table-3 for flammable or combustible dust mixtures
If you have | Then |
Flammable or explosive dust mixtures that may be present | Make sure the construction of equipment, including the exhaust system and all electrical wiring, meets both of the following: |
The American National Standard Installation (ANSI) of Blower and Exhaust Systems for Dust, Stock, and Vapor Removal or Conveying, NFPA 91. 2004. | |
The electrical requirements for Class II locations in WAC 296-24-95613, located in Part L of chapter 296-24 WAC. | |
Make sure blast cleaning enclosures, the ducts, and the dust collector are constructed with either loose panels or explosion venting areas that meet all of the following: | |
Provides pressure relief in case of an explosion. | |
Are located away from occupied areas. | |
The Guide for Deflagations, NFPA 68. 2002. |
[]
You must:
Make sure the exhaust ventilation system is fully operational by checking the static pressure drop at the exhaust ducts leading from the equipment at both of the following times:
When installation is completed
Annually after installation.
Repair or clean exhaust systems when either of the following occur:
Dust leaks are found; or
The pressure drop gauge indicates a change exceeding 20 percent.
Use an abrasive separator to separate larger particles for reuse on installations where abrasive is recirculated.
Set up dust collecting equipment to do both of the following:
Empty and remove accumulated dust without contaminating work areas
Discharge the air used in blast cleaning equipment.
Note: | Dispose fine dust from dry collectors by doing one of the following: |
Emptying and transporting the fine dust in enclosed containers | |
Using a sluice with a wetting process to contain the dust. |
[]
Abrasive:
A solid granular substance used in abrasive blasting operations.
Abrasive blasting:
The forcible application of an abrasive to a surface using either:
Pneumatic or hydraulic pressure;
OR
Centrifugal force
Abrasive-blasting respirator:
A supplied air or a continuous flow respirator constructed with a shroud that covers and protects the head, neck, and shoulders.
Automatic blast cleaning systems:
A unit that has a blast cleaning chamber which usually has both of the following to provide a timed cleaning cycle:
An automatic timer;
AND
An automatic shutoff control
Baffles:
Partial enclosures in and around the emission sources which improve or enhance airflow at the hood.
Blast cleaning barrel:
A complete enclosure that rotates on an axis or an internal tread to tumble parts in order to expose various surfaces of the parts to an automatic blast spray.
Blast cleaning room:
An enclosed room where blasting operations are performed by an operator who works from inside the room using a blasting nozzle to direct the flow of abrasive material.
Blasting cabinet:
An enclosure where the operator stands outside using a blasting nozzle through an opening, or openings in the enclosure.
Dust collector:
A device in an exhaust ventilation system used to remove dust from air.
Exhaust ventilation system:
A system that removes contaminated air using the following:
Enclosure or hood
Duct work
Dust collecting equipment
Exhauster
Discharge stack
Local exhaust ventilation:
The mechanical removal of contaminated air from the point where the contaminant is being generated or liberated.
Make-up air systems:
A ventilation system that controls the volume of outdoor air supplied to a building to replace air being exhausted.
Rotary blast cleaning table:
An enclosure where the pieces to be cleaned are placed on a rotating table and passed automatically through a series of blast sprays.
Tempered make-up air:
Air which has been conditioned by changing its heat content to get a specific desired temperature.
Ventilation:
The provision, circulation or exhausting of air into or from an area or space.
[]
OTS-8594.1
AMENDATORY SECTION(Amending WSR 05-03-093, filed 1/18/05,
effective 3/1/05)
WAC 296-304-03005
Mechanical paint removers.
(1) Power
tools.
(a) The employer must ensure that employees engaged in the removal of paints, preservatives, rusts or other coatings by means of power tools are protected against eye injury by goggles or face shields that meets the requirements of WAC 296-304-09005 (1) and (2).
(b) All portable rotating tools used for the removal of paints, preservatives, rusts or other coatings shall be adequately guarded to protect both the operator and nearby workers from flying missiles.
(c) Portable electric tools shall be grounded in accordance with the requirements of WAC 296-304-08003 (1) and (2).
(d) In a confined space, the employer must provide mechanical exhaust ventilation sufficient to keep the dust concentration to a minimum, or must protect employees by respiratory protective equipment that meets the requirements of chapter 296-842 WAC.
(2) Flame removal.
(a) The employer must ensure that when hardened
preservative coatings are removed by flame in enclosed spaces,
the employees exposed to fumes are protected by air line
respirators that meet the requirements of chapter 296-842 WAC.
Employees performing this operation in the open air, and
those exposed to the resulting fumes, must be protected by a
fume filter respirator that meets the requirements of chapter
296-842 WAC ((296-62-071)).
(b) Flame or heat shall not be used to remove soft and greasy preservative coatings.
(3) Abrasive blasting.
(a) Equipment. Hoses and fittings used for abrasive blasting shall meet the following requirements:
(i) Hoses. Hose of a type to prevent shocks from static electricity shall be used.
(ii) Hose couplings. Hose lengths shall be joined by metal couplings secured to the outside of the hose to avoid erosion and weakening of the couplings.
(iii) Nozzles. Nozzles shall be attached to the hose by fittings that will prevent the nozzle from unintentionally becoming disengaged. Nozzle attachments shall be of metal and shall fit onto the hose externally.
(iv) Dead man control. A dead man control device shall be provided at the nozzle end of the blasting hose either to provide direct cutoff or to signal the pot tender by means of a visual and audible signal to cut off the flow, in the event the blaster loses control of the hose. The pot tender shall be available at all times to respond immediately to the signal.
(b) Replacement. Hoses and all fittings used for abrasive blasting shall be inspected frequently to insure timely replacement before an unsafe amount of wear has occurred.
(c) Personal protective equipment.
(i) The employer must ensure that abrasive blasters
working in enclosed spaces are protected by abrasive blasting
respirators that meet the requirements of ((WAC 296-24-675))
chapter 296-818 WAC, Abrasive blasting and chapter 296-842 WAC.
(ii) The employer must ensure that abrasive blasters working in the open are protected as required in subsection (1) of this section.
(v) A surge from a drop in pressure in the hose line can
throw a blaster off the staging. To protect against this
hazard, the employer must ensure that a blaster is protected
by a personal fall arrest system, that meets the requirements
of WAC 296-304-09021. The personal fall arrest system must be
tied off to the ship or other structure during blasting from
elevations where adequate fall protection cannot be provided
by railings.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
49.17.060. 05-03-093, § 296-304-03005, filed 1/18/05,
effective 3/1/05. Statutory Authority: RCW 49.17.010,
[49.17].040 and [49.17].050. 99-10-071, § 296-304-03005,
filed 5/4/99, effective 9/1/99. Statutory Authority: RCW 49.17.040, [49.17].050 and [49.17].060. 98-02-006, §
296-304-03005, filed 12/26/97, effective 3/1/98. Statutory
Authority: Chapter 49.17 RCW. 95-04-006, § 296-304-03005,
filed 1/18/95, effective 3/10/95; 93-19-142 (Order 93-04), §
296-304-03005, filed 9/22/93, effective 11/1/93; Order 76-7, §
296-304-03005, filed 3/1/76; Order 74-25, § 296-304-03005,
filed 5/7/74.] OTS-8592.1 PART L -- ATMOSPHERES((
[Statutory Authority: RCW 49.17.040, [49.17].050 and
[49.17].060. 98-02-006, § 296-62-11015, filed 12/26/97,
effective 3/1/98. Statutory Authority: Chapter 49.17 RCW. 91-24-017 (Order 91-07), § 296-62-11015, filed 11/22/91,
effective 12/24/91. RCW 49.17.040, 49.17.050, and 49.17.240. 81-16-015 (Order 81-20), § 296-62-11015, filed 7/27/81;
80-11-010 (Order 80-14), § 296-62-11015, filed 8/8/80; Order
73-3, § 296-62-11015, filed 5/7/73.] The following section of the Washington Administrative Code is repealed: OTS-8591.1 The following sections of the Washington Administrative Code are repealed:
Exception:
When synthetic abrasives containing less than one percent free silica are used, the employer may
substitute particulate or dust filter respirators that are approved by the National Institute of Safety and
Health (NIOSH) and used according to chapter 296-842 WAC.
(iii) The employer must ensure that employees, including
machine tenders and abrasive recovery workers, working in
areas where unsafe concentrations of abrasive materials and
dusts are present are protected by eye and respiratory
protective equipment that meets the requirements of WAC 296-304-09005 (1) and (2) and chapter 296-842 WAC.
Exception:
This requirement does not apply to blasters.
(iv) The employer must ensure that a blaster is protected
against injury from exposure to the blast by appropriate
protective clothing, including gloves that meet the
requirements of WAC 296-304-09015(1).,)) AND VENTILATION((, EMERGENCY
WASHING))
AMENDATORY SECTION(Amending WSR 98-02-006, filed 12/26/97,
effective 3/1/98)
WAC 296-62-11015
Abrasive blasting.
Abrasive blasting
is covered in ((the General safety and health standards WAC 296-24-675, Safe practices of abrasive blasting operations
(Part H-2))) chapter 296-818 WAC, Abrasive blasting.
REPEALER
WAC 296-62-12007
Effective date.
REPEALER
WAC 296-24-675
Safe practices of abrasive
blasting operations.
WAC 296-24-67501
Purpose.
WAC 296-24-67503
Application.
WAC 296-24-67505
Selection of abrasives and
equipment.
WAC 296-24-67507
Definitions.
WAC 296-24-67509
Dust hazards from abrasive
blasting.
WAC 296-24-67511
Blast cleaning enclosures.
WAC 296-24-67513
Construction and maintenance of
the exhaust ventilation systems.
WAC 296-24-67515
Personal protective equipment.
WAC 296-24-67517
Air supply and air compressors.
WAC 296-24-67519
Operational procedures and
general safety.
WAC 296-24-67520
Ventilation.
WAC 296-24-67521
Appendix 1.
© Washington State Code Reviser's Office